Technical information

80 Setup AccuLazr™ AL5010 Product Line Manual
Modify Settings > Raster
Use Modify Settings > Raster to define the laser sweep area of an AL5010
with the optional adjustable raster feature. It also allows you to set the
oscillating frequency (speed) of the vibrating mirror.
The sweep of the laser is determined by the amount of coverage your
application requires (possible label position) and the distance of the laser
scanner from the object being scanned. The laser sweep is adjustable from
20-degrees above 0 (the center laser position) or -20-degrees below 0.
Examples:
If the Upper Sweep is set to 15-degrees and the Lower Sweep is
set to 10-degrees, the total coverage will be 25-degree
encompassing 0.
If the Upper Sweep is set to -5-degrees and the Lower Sweep is
set to -15-degrees, the total coverage will be 10-degrees, but below
the 0 position.
If the Upper Sweep and Lower Sweep are both set to -10 degrees,
the laser will remain static at 10-degrees below the 0 position.
To Set the Sweep of the Laser:
1. Enter a value in the Upper Sweep text field between -20 and 20.
2. Enter a value in the Lower Sweep text field between -20 and 20.
3. Click Update. 0.
To Set the Oscillating Frequency:
1. Enter a value in the Oscillating Frequency text field between 0 and 4. A
value of 0 will stop oscillation, while values above 0 will increase the
speed of the oscillation up to the fastest at a value of 4.
2. Click Update. 0.
See also: Chapter 3: Mechanical Installation > Raster Setup.
Accu-Sort Systems, Inc. 05-AL5010_Setup_R20.doc