TROUBLESHOOTING GUIDE 
Problem Suggestion 
One Shot or Phase Mode 
using serial trigger source: 
the ”TRIGGER” LED is not 
blinking. 
  In the Operating Mode folder check the settings for 
Reading Phase-ON, Acquisition Trigger and 
Reading Phase-OFF parameters. 
  Are the COM port parameters (Baud Rate, Parity, Data 
Bits, Stop Bits, Handshake) correctly assigned? 
  In the communication folder, check the settings of 
Reading Phase-ON String, Acquisition Trigger 
String and Reading Phase-OFF String parameters. 
  Is the serial trigger source correctly connected? 
Phase Mode: 
the ”TRIGGER" LED is 
correctly blinking but no image 
is displayed in VisiSet™ 
Calibration Tool window. 
  Is the Phase frequency lower than the maximum frame 
rate? 
Continuous Mode: 
the ”TRIGGER” LED is not 
blinking. 
  Verify the correct software configuration settings. 
Any Operating Mode: 
the ”TRIGGER” LED is 
correctly blinking but no result 
is transmitted by the reader at 
the end of the reading phase 
collection. 
  In the Data Collection folder check the settings for the 
CODE COLLECTION, DATA FORMAT and 
STATISTICS parameter groups. 
Image not clear: 
  Verify the Focus procedure 
Image focused but not 
decoded: 
  Verify the Calibrate Image Density prodcedure. 
Reading: 
the reader always transmits 
the No Read Message 
  Run the Rapid Configuration procedure in chapter 1. 
  Position the reader as described in par. 3.3 and through 
the VisiSet™ Calibration Tool: 
  Tune the ACQUISITION TRIGGER DELAY, if the 
moving code is out of the reader field of view; 
  Set the Continuous Operating Mode if no external 
trigger source is available; 
  Tune the IMAGE ACQUISITION SETTING to 
improve the code image quality; 
  Check the parameter setting in Decoding, 
2D Codes, 1D Codes, and Postal Codes folders; 
  View the full resolution code image to check the 
printing or marking quality. 
Communication: 
reader is not transmitting 
anything to the host. 
  Is the serial cable wiring correct? 
  If using CBX, be sure the RS485 termination switch is 
OFF. 
  Are the host serial port settings the same as the reader 
serial port settings? 
  In VisiSet™ Digital I/O folder, "COM" LED can be 
configured to indicate MAIN COM port TX or MAIN 
COM port RX. 