RAPID CONFIGURATION 
1
7
3. 
Refer to the Reading Features table in chp. 7 to determine the distance your reader 
should be p
ositioned at. 
NOTE 
Rapid Configuration of the Matrix 200™ reader can be made either through 
the X-PRESS™ interface (steps 3-4) which requires no PC connection, or by 
using the VisiSet™ Setup Wizard (steps 5-6). Select the procedure according 
to your needs. 
STEP 3 – AIM THE READER 
Matrix 200™ provides a built-in aiming system to aid reader positioning. The aiming system 
is accessed through the X-PRESS™ Interface. 
1.  Power the reader on. During the reader startup (reset or restart phase), all the LEDs blink 
for one second. On the connector side of the reader near the cable, the “POWER ON” 
LED (blue) indicates the reader is correctly powered. 
2.  Enter the Aim/Locate function by pressing and holding the X-PRESS™ push button until 
the Aim LED is on. 
3.  Release the button to enter the Aim function. The aiming system turns on see Figure 7. 
4. 
Place the application specific code in front of the reader at the reading distance indicated 
for your model in the Reading Features table, centering it in the aiming system indicator. 
FOV
default value for: 
UHD models 
default value for: 
NEAR, MEDIUM, 
FAR models 
FOV
Figure 7 – Aiming Function Using The Blue Ring or 
Internal Lighting System * 
green 
green 
yellow 
yellow 
red 
Figure 8 – X-PRESS™ Interface: Aim Function 
* the default value of the Aiming System Status parameter can be changed in VisiSet™. 
5.  Exit the Aim function by pressing the X-PRESS™ push button once. The aiming system 
turns off. 