Instruction manual
MATRIX 200™ REFERENCE MANUAL 
2 
Setup (Function 3) 
Once entered, the imager automatically performs Image Acquisition parameter calibration for 
the specific code presented to it. 
The Setup LED will blink until the procedure is completed. 
The Setup procedure ends when the Image Acquisition parameters are successfully saved in 
the reader memory, the Setup LED will remain on continuously and Matrix 200™ emits 3 high 
pitched beeps. 
If the calibration cannot be reached after a timeout of about 5 (five) seconds Matrix 200™ will 
exit without saving the parameters to memory, the Setup LED will not
 remain on continuously 
but it will just stop blinking. In this case Matrix 200™ emits a long low pitched beep. 
Learn (Function 4) 
Once entered, the imager starts a procedure to automatically detect and recognize codes 
which are presented to it. 
The Learn LED will blink until the procedure is completed. 
The Learn procedure ends when the Image Processing and Decoding parameters are 
successfully saved in the reader memory, the Learn LED will remain on continuously and 
Matrix 200™ emits 3 high pitched beeps. 
If the calibration cannot be reached after a timeout of about 3 (three) minutes, Matrix 200™ will 
exit without saving the parameters to memory, the Learn LED will not
 remain on continuously 
but it will just stop blinking. In this case Matrix 200™ emits a long low pitched beep. 
2.5  MODEL DESCRIPTION 
The Matrix 200™ reader is available in different versions according to the following 
characteristics: 
MATRIX 200 XXX-
X
XX
Illuminators 
1 = Internal Illuminator 
Focus Distance
1 = Near 
2 = Medium 
3 = Far 
4
 = UHD 
Sensor Size
2 = WVGA (1280x1024) 
Reading Window 
0 = 90° 
1 = Straight 
Interface 
0 = Serial 
2 = USB 
Options
0 = Standard 
1 = ESD Safe 
2 = ESD Safe + YAG Cut Filters 
24 