Instruction manual
MATRIX 200â„¢ REFERENCE MANUAL 
4 
Pulled up to External 
Input Device Power 
Input 
Signal 
Input Device 
Figure 55 - NPN Input 2 Using External Power 
4.6  OUTPUTS 
Two optocoupled general purpose outputs are available. The meaning of the two outputs 
Output 1 and Output 2 can be defined by the user. They are typically used either to signal the 
data collection result or to control an external lighting system. 
CBX100/500
  Function 
+V  Power Source - Outputs 
O1+  Output 1 + 
O1-  Output 1 - 
O2+  Output 2 + 
O2-  Output 2 - 
-V  Power Reference Outputs 
The electrical features of the two outputs are the following: 
V
CE
 = 30 Vdc max. 
I
CE
 = 40 mA continuous max.; 130 mA pulsed max. 
By default, Output 1 is associated with the Partial Read and No Read events, which activates 
when the code(s) signaled by the external trigger are not decoded, and Output 2 is 
associated with the Complete Read event, which activates when all the selected codes are 
correctly decoded. 
The output signals are fully programmable being determined by the configured 
Activation/Deactivation events, Deactivation Timeout or a combination of the two. Refer to 
the Digital I/O folder in the VisiSetâ„¢ Help On Line for further details. 
48 