Instruction manual
25-PIN CABLE ELECTRICAL CONNECTIONS 
5
5  25-PIN CABLE ELECTRICAL CONNECTIONS 
5.1  25-PIN CONNECTOR 
The Matrix 200™ reader is equipped with a 25-pin male D-sub connector for connection to 
the power supply, serial interfaces and input/output signals. The details of the connector pins 
are indicated in the following table: 
13
2514
1 
Figure 60 - 25-pin Male D-sub Connector 
25-pin D-sub male connector pinout 
Pin Name  Function 
13, 9  Vdc  Power supply input voltage + 
25, 7  GND  Power supply input voltage - 
1  CHASSIS  Cable shield connected to chassis 
18  I1A  External Trigger A (polarity insensitive) 
19  I1B  External Trigger B (polarity insensitive) 
6  I2A  Input 2 A (polarity insensitive) 
10  I2B  Input 2 B (polarity insensitive) 
8  O1+  Output 1 + 
22  O1-  Output 1 - 
11  O2+  Output 2 + 
12  O2-  Output 2 - 
20  RX  Auxiliary RS232 RX 
21  TX  Auxiliary RS232 TX 
23 ID+  ID-NET™ network + 
24 ID-  ID-NET™ network - 
14, 15, 16, 17  NC  Not Connected 
Pin Name RS232 
RS485 
Full-Duplex 
RS485 
Half-Duplex 
2 TX TX+ RTX+ 
3 RX *RX+ 
4 RTS TX- RTX- 
5 
MAIN INTERFACE 
(SW SELECTABLE)
CTS  *RX- 
* Do not leave floating, see par. 5.3.2 for connection details.
In order to meet EMC requirements: 
  connect the reader chassis to the plant earth ground by means of a flat copper braid 
shorter than 100 mm; 
  for direct connections, connect the main interface cable shield to pin 1 of the 25-pin 
connector. 
51