Instruction manual
25-PIN CABLE ELECTRICAL CONNECTIONS 
5
5.3.1  RS232 Interface 
The RS232 interface can be used for Point-to-Point, Pass Through or Master/Slave 
connections. When it is connected to the host computer it allows both transmission of code 
data and reader configuration by VisiSet™. 
The following pins of the 25-pin connector are used for RS232 interface connection: 
Pin Name  Function 
2 TX  Transmit Data 
3 RX  Receive Data 
4  RTS  Request To Send 
5  CTS  Clear To Send 
7 GND  Ground 
It is always advisable to use shielded cables. The overall maximum cable length must be 
less than 15 m (49.2 ft). 
Matrix 200™ 
7 
4 
5 
3 
GND 
RTS 
CTS 
RX 
TX 
2 
USER INTERFACE 
GND 
CTS 
RTS 
TXD 
RXD 
1 
Chassis 
Figure 62 - RS232 Main Interface Connections Using Hardware Handshaking 
The RTS and CTS signals control data transmission and synchronize the connected devices. 
Figure 63 - RS232 Control Signals 
If the RTS/CTS handshaking protocol is enabled, Matrix 200™ activates the RTS output to 
indicate a message is to be transmitted. The receiving unit activates the CTS input to enable 
the transmission. 