Instruction manual
MATRIX 200™ REFERENCE MANUAL 
5 
INPUT 2 CONNECTI
ONS USING EXTERNAL POWER 
Matrix 200™ 
INPUT DEVICE 
Vext 30 Vdc max.
I2A 
6
10
I2B 
V
CC
~ 
~ 
+ 
-
V
Signal 
Figure 80 - PNP Input 2 Using External Power 
Matrix 200™ 
INPUT DEVICE 
Vext 30 Vdc max.
I2A 
6
10
Signal 
V
I2B 
V
CC
~ 
~ 
+ 
-
Figure 81 - NPN Input 2 Using External Power 
5.7  OUTPUTS 
Two opto-coupled general purpose outputs are available on the 25-pin connector. The 
meaning of the two outputs Output 1 and Output 2 can be defined by the user. They are 
typically used either to signal the data collection result. 
The pinout is the following: 
Pin Name  Function 
9  Vdc  Power Supply input voltage + 
8  O1+  Configurable digital output 1 - positive pin 
22  O1-  Configurable digital output 1 - negative pin 
11  O2+  Configurable digital output 2 - positive pin 
12  O2-  Configurable digital output 2 - negative pin 
7  GND  Power Supply input voltage - 
The electrical features of the two outputs are the following: 
V
CE
 max = 30 Vdc 
I max = 40 mA continuous; 130 mA pulsed 
By default, Output 1 is associated with the Partial Read and No Read events, which activates 
when the code(s) signaled by the external trigger are not decoded, and Output 2 is 
associated with the Complete Read event, which activates when all the selected codes are 
correctly decoded. 
66 