Specifications
Matrix-2000™ Reference Manual 
3 
3.3.2 Main Serial Interface 
The signals relative to the following serial interface types are available on the 25-pin 
connector: 
 RS232 (default setting) 
  RS485 FULL DUPLEX 
RS485 HALF DUPLEX 
The main serial interface type and its parameters (baud rate, data bits, etc.) can be 
defined by the user via VisiSet™ software. The RS485 half duplex is automatically set 
whenever MUX32 communication protocol is enabled. For more details refer to the 
"Communication" folder in the VisiSet™ Help On Line. 
Details regarding the connections and use of the main interface selection are given in the 
next paragraphs. 
RS232 Interface 
The opto-isolated RS232 interface can be used for Point-to-Point, Pass Through or 
Master/Slave connections. When it is connected to the host computer it allows both 
transmission of code data and reader configuration by VisiSet™. 
The following pins of the 25-pin connector are used for RS232 interface connection: 
Pin Name  Function 
2 TX232  Transmitted data 
3 RX232  Received data 
4  RTS232  Request to send 
5  CTS232  Clear to send 
7  GND_ISO  Main opto-isolated reference ground 
30 










