6 TROUBLESHOOTING 
6.1 GENERAL GUIDELINES 
•  When wiring the device, pay careful attention to the pin number of the signals and whether 
you are referring to the 25-pin connector or to the C-BOX 100 spring clamp connectors. 
•  If you need information about a certain reader parameter you can refer to the VisiSet™ 
program help files. Either connect the device and select the parameter you’re interested in 
by pressing the F1 key, or select Help>Paramters Help from the command menu. 
•  If you’re unable to fix the problem and you’re going to contact your local Datalogic office or 
Datalogic Partner or ARC, we suggest providing (if possible): Application Program version, 
Parameter Configuration file, Serial Number and Order Number of your reader. You can 
get this information while VisiSet™ is connected to the reader: the Application Program 
version is shown in the Terminal Window; the Parameter Configuration can be saved to an 
.ini file applying the File>Save Configuration File command in the Parameter Setup 
window; Serial Number and Order Number can be obtained by applying the respective 
command in the Tools menu. 
TROUBLESHOOTING GUIDE 
Problem Suggestion 
Power ON: 
the “PWR” LED is not lit. 
•  Is power connected? 
•  If using a power adapter (like PG6000), is it connected 
to wall outlet? 
•  If using rail power, does rail have power? 
•  If using C-BOX 100, does it have power (check switch 
and LED)? 
•  Check if you are referring to the 25-pin connector or to 
the C-BOX 100 spring clamp connectors. 
•  Measure Voltage either at pin 13 and pin 25 (for 25-pin 
connector) or at spring clamp 1 and 2 (for C-BOX 100). 
After Power ON: 
the "READ" LED is lit or 
blinking without any code in 
front of the reader and the 
connection to VisiSet™ fails. 
•  Contact your local Datalogic Automation office or 
Datalogic Automation Partner or ARC. See also 
http://www.automation.datalogic.com/ under Partners. 
One Shot or Phase Mode: no 
image is displayed in Visiset™ 
Calibration Tool window while 
your trigger source is working. 
•  In the Operating Mode folder check the settings of 
Reading Phase-ON, Acquisition Trigger and 
Reading Phase-OFF parameters. 
•  In Digital I/O folder set the echo of Phase or Acquisition 
Trigger on a reader output (if it is available) and in Run 
Mode check if the reader correctly receives your trigger 
and repeats it on the output. If this doesn't happen, 
check the Trigger source cabling. 
•  In the Digital I/O folder check the 
EXTERNAL TRIGGER\Debounce Filter parameter 
setting. 
•  Is the Phase frequency lower than the maximum frame 
rate? 