User`s manual
DL TCL™ 
48 
4 
-  Terminator key:  defines the key to be pressed to include a terminator 
character in the output data format. Possible selections are: 
None = no terminator added to the data string 
Enter = terminator ASCII value is 13 
Tab = terminator ASCII value is 08 
Field Exit = special key available in the AS400 emulation 
(only for IBM5250/3270 terminal emulation). 
-  Code Type:  opens further masks listing all available code types for the 
connected terminal: 
Code 39 standard  UPC-A  MSI 
Code 39 full ASCII  UPC-E  Code 11 
Code 39 CIP  EAN-8  Code 93 
Italian Pharmaceutical  EAN-13  PDF-417 
Interleaved 2/5  Codabar  Micro PDF 
Industrial 2/5  Code 128   
Matrix 2/5  EAN-128   
  The selection of a code type within the mask is signaled by 
displaying the code in reverse video. 
-  Clrbefore SCAN:  This “Clears Before Scan” key is only available in 
connection with an AS400 Host. It defines whether clearing 
the input field before sending the code barcode read. 
  Printer 
It defines the type of printer port through which sending data from the terminal to the 
printer. 