Installation manual

INSTALLATION
31
3
To fix a DS2400N Scanner to the GFC-200, use the two M 4 x 6 mm screws supplied with
the GFC Kit. Refer to the following figure.
Figure 23 – Fixing DS2X00N Scanner to GFC-200
The GFC-200 85° contact reading mirror assures that the minimum skew angle is maintained
to avoid direct light reflection which can degrade reading performance.
When reading very reflective barcodes, it may be necessary to increase the skew angle (up
to 10° - 15°). In this case, the GFC-200 should be mounted with a corresponding inclination.
up to 10°/15°
85°
Code Surface
Figure 24 – Maintaining Minimum Skew Angle