DS4800 OM QUICK REFERENCE GUIDE 4 3 5 2 6 1 Figure A NOTE 1 "POWER ON" LED 4 Display 2 Focus Adjustment 5 Laser Beam Output Window 3 Indicator LEDs 6 Push Button This manual illustrates a Stand Alone application. For other types of installations, such as ID-NET™, Pass-Through, Multiplexer Layout, etc. and for a complete scanner configuration using Genius™ configuration program, refer to the DS4800 Reference Manual available on the CD.
DS4800 OM QUICK GUIDE UPDATES AND LANGUAGE AVAILABILITY UK/US The latest drivers and documentation updates for this product are available on Internet. Log on to: www.automation.datalogic.com I Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto. Questo manuale è disponibile anche nella versione italiana. Collegarsi a: www.automation.datalogic.com F Les versions mises à jour de drivers et documentation de ce produit sont disponibles sur Internet.
DS4800 OM QUICK GUIDE STEP 1 – CONNECT THE SYSTEM To connect the system in a Stand Alone configuration, you need the hardware indicated in Figure 1. In this layout the data is transmitted to the Host on the main serial interface. In Local Echo communication mode, the RS232 auxiliary interface can be used to transmit data independently from the main interface selection.
DS4800 OM QUICK GUIDE 25-pin Connector Pinout for DS4800 OM The table below gives the pinout of the 25-pin male D-sub connector for connection to the power supply and input/output signals.
DS4800 OM QUICK GUIDE STEP 2 – MOUNT AND POSITION THE SCANNER 1. To mount the DS4800 OM, use the mounting bracket to obtain the most suitable position for the reader as shown in the figures below. Skew -45° -15° alignment marks 0° 15° 45° Tilt Figure 3 - Positioning with Mounting Bracket 2. When mounting the DS4800 OM take into consideration these three ideal label position angles: Skew 15° to 30°, Tilt 0° and Pitch 0°.
DS4800 OM QUICK GUIDE The DS4800 OM is completely software controlled and software programmable through Genius™ which allows adjusting the oscillating frequency and the minimum and maximum oscillation angles of two separate reading zones. When the oscillating mirror is programmed to read barcode labels at small angles, position the reader to assure at least 15° for the Skew angle. This angle refers to the most inclined or external laser line, so that all other laser lines assure more than 15° Skew.
DS4800 OM QUICK GUIDE STEP 3 – FOCUS THE SCANNER The reading distance depends on the focus distance of the scanner and should be set according to the application requirements. The Focus Position is set directly through the focus adjustment screw on the front panel of the scanner. This screw moves the internal lens of the scanner to change the focal length of the scanner.
DS4800 OM QUICK GUIDE STEP 4 – X-PRESS™ CONFIGURATION X-PRESS™ is the intuitive Human Machine Interface designed to improve ease of installation and maintenance.
DS4800 OM QUICK GUIDE NOTE If the barcode cannot be read because of low contrast or excessive ambient light, you can perform the AutoSetup function to optimize the optical parameters. Then you can perform AutoLearn to recognize the barcode symbology. * In case of Programming Barcodes, refer to the “ID-NET™ Programming Barcodes And Setup Procedure” document in the product CD.
DS4800 OM QUICK GUIDE RESET SCANNER TO FACTORY DEFAULT (OPTIONAL) If it ever becomes necessary to reset the scanner to the factory default values, you can perform this procedure by holding the X-PRESS™ push button pressed while powering up the scanner. At the end of the procedure (about 5-6 seconds), the Configuration and Environmental parameters are reset, all LEDs blink simultaneously 3 times and the message "Default Set" is shown on the display.
DS4800 OM QUICK GUIDE STEP 5 – INSTALL GENIUS™ CONFIGURATION PROGRAM Genius™ is a Datalogic scanner configuration tool providing several important advantages: Wizard approach for new users; Multi-language version; Defined configuration directly stored in the reader; Communication protocol independent from the physical interface allowing to consider the reader as a remote object to be configured and monitored.
DS4800 OM QUICK GUIDE a. Barcode selection and definition b. Operating mode selection and definition c. Digital Outputs configuration d. Hardware interface selection e. Output data format configuration The On Line operating Mode requires the reader to be connected to an External Trigger/Presence Sensor using I1A and I1B inputs. The Automatic operating mode does not require connection to an external Presence Sensor.
DS4800 OM QUICK GUIDE 2. After defining the parameter values the following window appears allowing to complete the reader configuration as follows: Saving the configuration to disk; Switching to Advanced mode; Sending the configuration to the scanner. 3. After sending the configuration to the scanner you have completed the configuration process. 4. By clicking Finish, the System Information window will be displayed with specific information concerning the scanner.
DS4800 OM QUICK GUIDE OM CONFIGURATION PARAMETERS The DS4800 OM scanner is configurable exclusively through the Genius™ utility program. The DS4800 scanner must have software version 004 or later. NOTE The following software configuration parameters are available through Genius™ and described below for reference: Oscillating Mode This parameter defines the oscillating mode of the scanner mirror: Selections: Fixed Continuous the oscillating mirror deflects the scan line at a fixed Angle (default 0°).
DS4800 OM QUICK GUIDE Second Zone Trigger This parameters defines the number of the input or the phase working as trigger. Selections: Phase (available only when working in On Line operating mode) Input 1 Input 2 Second Zone Trigger Level This parameter allows setting the active state of the trigger.
DS4800 OM QUICK GUIDE STEP 6 – TEST MODE Use a code suitable to your application to test the system. Alternatively, you can use the Datalogic Test Chart (Code 128). NOTE When entering the X-PRESS™ interface on the DS4800 Oscillating Mirror remains in the default fixed position (0°) in order to make barcode reading easier while performing the X-PRESS™ functions. 1. Enter the Test mode function by holding the X-PRESS™ push button pressed until the TEST LED is on. 2.
DS4800 OM QUICK GUIDE ADVANCED SCANNER CONFIGURATION For further details on advanced product configuration, refer to the complete Reference Manual on the installation CD-ROM or downloadable from the web site through this link: www.automation.datalogic.com/ds4800. The following are alternative or advanced scanner configuration methods: HOST MODE PROGRAMMING The scanner can also be configured from a host computer using the Host Mode programming procedure, by commands via the serial interface.
DS4800 OM QUICK GUIDE APPENDIX READING DIAGRAMS DS4800 OM-X1XX Focus Distance 30 cm (Near) 0 0 20 50 15 40 CONDITIONS Code = Code 128 PCS = 0.90 Pitch angle = 0° Skew angle = 15° Tilt angle = 0° to 30° *Scan Speed = 800 scans/sec *Reading Conditions = Standard *Reading Mode = Linear 20 30 30 15 20 40 50 0.50 mm (20 mils) 20 5 0 5 10 0 10 20 10 30 15 40 20 50 (cm) (in) 18 10 10 10 * Parameter selectable in Genius™ (0,0) corresponds to the scanner output window 5 0.
DS4800 OM QUICK GUIDE DS4800 OM-X1XX Focus Distance 40 cm (Medium) 0 0 20 50 15 40 CONDITIONS Code = Code 128 PCS = 0.90 Pitch angle = 0° Skew angle = 15° Tilt angle = 0° to 30° *Scan Speed = 800 scans/sec *Reading Conditions = Standard *Reading Mode = Linear 10 20 30 15 20 40 50 25 60 30 70 80 35 40 (in) 90 100 (cm) 0.
DS4800 OM QUICK GUIDE READING PERFORMANCE Version Reading Distance Max Code Resolution mm (mils) Speed scans/s F = 30 Near 21 cm (8.3 in) - 43 cm (16.9 in) on 0.50 mm (20 mils) codes 0.20 (8) 800 F = 40 Medium 25 cm (9.8 in) - 64 cm (25.2 in) on 0.50 mm (20 mils) codes 0.30 (12) 800 F = 60 Far 39 cm (15.4 in) - 95 cm (37.4 in) on 0.50 mm (20 mils) codes 0.38 (15) 800 TECHNICAL FEATURES ELECTRICAL FEATURES Power Supply Max.
DS4800 OM QUICK GUIDE 13 [0.51] MØ5 42 [1.65] 10 [0.39] 42.5 [1.67] MØ5 MØ5 41.5 [1.63] 10 [0.39] 5.9 [0.23] 34 [1.34] 101 [3.98] mm [in] 7.8 [0.31] 87.7 [3.45] 5.2 [0.21] 37.8 [1.49] 27.9 [1.10] 7.8 [0.31] 7.5 [0.30] M M Ø4 37 [1.46] M Ø4 41.9 [1.65] 4 MØ 123.4 [4.86] Ø4 81 [3.19] 116.6 [4.59] 12.1 [0.48] Figure 11 – DS4800 OM Overall Dimensions 108 [4.25] 3 [0.12] 30 [1.18] 64.2 [2.53] 71.6 [2.82] 45° 100.6 [3.96] 15° ° 45 45° 15° 76.9 [3.
DS4800 OM QUICK GUIDE COMPLIANCE LASER SAFETY The scanner is classified as a Class 2 laser product according to EN 60825-1 regulations and as a Class II laser product according to CDRH regulations. This product conforms to the applicable requirements of 21CFR1040 at the date of manufacture Disconnect the power supply when opening the device during maintenance or installation to avoid exposure to hazardous laser light.
DS4800 OM QUICK GUIDE PATENTS This product is covered by one or more of the following patents: U.S. patents 5,992,740; 6,394,352 B1; 6,742,710 B2; 6,688,524 B1 European patents 789,315 B1; 959,426 B9 Additional patents pending.
DECLARATION OF CONFORMITY 09 Datalogic Automation S.r.l. Via S.