System information
DS4800 OM QUICK GUIDE
20
READING PERFORMANCE
Version Reading Distance Max Code Resolution
mm (mils)
Speed
scans/s
F = 30 Near 21 cm (8.3 in) - 43 cm (16.9 in) on 0.50 mm (20 mils) codes 0.20 (8) 800
F = 40 Medium 25 cm (9.8 in) - 64 cm (25.2 in) on 0.50 mm (20 mils) codes 0.30 (12) 800
F = 60 Far 39 cm (15.4 in) - 95 cm (37.4 in) on 0.50 mm (20 mils) codes 0.38 (15) 800
TECHNICAL FEATURES
ELECTRICAL FEATURES
Power Supply 10 to 30 Vdc
Max. Consumption
0.75 to 0.25 A; 7.5 W
Main Serial Interfaces
Baud Rate
Programmable:
RS232, RS485 FD and HD
1200 to 115200
Auxiliary Interface
Baud Rate
RS232
1200 to 115200
ID-NET™ Interface
Baud Rate
RS485 Half Duplex
Up to 1Mbaud
Inputs
Input 1 (External Trigger), Input 2
Voltage
Current Consumption
Minimum Pulse Duration
Optocoupled, polarity insensitive
10 to 30 Vdc
12 mA max.
5 ms
Outputs
Output 1, Output 2
V
CE
Collector Current
V
CE Saturation
Power Dissipation
Optocoupled
30 Vdc max.
40 mA continuous max.; 130 mA pulsed max.
1V max. at 10 mA
80 mW max. at 45 °C (ambient temperature)
OPTICAL FEATURES
Light Source Semiconductor laser diode
Wavelength In the range 630 to 680 nm
Safety Class Class 2 – EN 60825-1; CDRH
READING FEATURES
Scan Rate (software programmable) 600 to 900 scans/sec
Aperture Angle 50°
Oscillating Amplitude 40° (-5° to 35°)
Oscillating Frequency 0.2 to 20 Hz; 5 Hz max @ 40°; 20 Hz max @ 10°
Maximum Reading Distance
Maximum Resolution
See reading diagrams
ENVIRONMENTAL FEATURES
Operating Temperature 0° to +50 °C (+32° to +122 °F)
Storage Temperature -20° to +70 °C (-4° to +158 °F)
Humidity max. 90% non condensing
Vibration Resistance
EN 60068-2-6
14 mm @ 2 to 10 Hz; 1.5 mm @ 13 to 55 Hz;
2 g @ 70 to 200 Hz; 2 hours on each axis
Shock Resistance
EN 60068-2-27
30 g; 11 ms;
3 shocks on each axis
Protection Class – EN 60529 IP65
Ambient Light Rejection 30,000 LUX
PHYSICAL FEATURES
Dimensions
123 x 117 x 48 mm (4.8 x 4.6 x 1.9 in)
Weight 780 g (27.9 oz)
USER INTERFACE
LED Indicators
Ready, Good, Trigger, Com, Status, Power On
Multi-function Key X-PRESS™ button
Display
2 lines x 16 characters
menu and diagnostic messages configurable in various languages
If the reader is used in high temperature environments (over 40 °C), use of the Beam Shutter is advised (see the Genius™
configuration program) and/or a thermally conductive support (such as the metal bracket provided).