User`s manual

FORMULA COLORâ„¢
3
3.6.1 Console
ITEM VALUES DESCRIPTION NOTE
Scroll
Software
Track
Virt
Both (*)
Scrolling mode
See Scrolling Mode
note below
Contrast Ranged: 0..127 (65) LCD contrast
See Contrast note
below
Light always on (*)
5s, 10s, 15s, 30s, 1m,
2m, 3m, 5m, 10m,
15m, 30m
Timeout for the
backlight
Intensity
Low
High (*)
Backlight intensity
Kbd click
Enable (*)
Disable
Keyboard click
Kbd freq. Ranged: 1..100 (3)
Keyboard click
Frequency
(100 Hz steps)
Password
String up to 8
characters
Selection of the new
password to enter
setup
Simply press
[ENTER] to disable
the password
Scrolling Mode
The Formula Colorâ„¢ display adapter allows the application to write on a virtual 25
lines by 80 columns display. On the other hand, the user can see only a portion of
this virtual display at a time, which we call the physical display.
The "scroll" parameter controls which portion of the virtual display is seen by the
user. The display can always be scrolled by the application program.
Software: the physical display position is fixed. It can be moved only by the
application program.
Track: the physical display follows the cursor vertically only through BIOS.
Virt: it is only possible to scroll the display by the keyboard.
Both: Both the Virtual and Track mode are enabled.
Contrast
The CMOS value of LCD contrast represents the only parameter that can be
modified outside the BSETUP.EXE application. As a matter of fact, selecting the
contrast mode [FUNC]-[4] gives you the ability to change this value using the up and
down arrows; this changing does not affect the EEPROM value.
14