Gryphon I GFS4400 Fixed Mount Area Imager Bar Code Reader Product Reference Guide
Datalogic ADC, Inc. 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic ADC, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic ADC”).
Table of Contents INTRODUCTION ................................................................................................................................................................................ 9 About this Manual .......................................................................................................................................................................................... 9 Overview ......................................................................................
Contents USB-OEM Device Usage ................................................................................................................................................................................................48 Transmit Labels in Code 39 Format ..........................................................................................................................................................................49 Interface Options ..............................................................
Contents Multiple Labels Ordering by Code Length ............................................................................................................................................................92 Symbologies ........................................................................................................................................................................... 93 1D Code Selection ..................................................................................................
Contents Code 39 LaPoste Enable/Disable ............................................................................................................................................................................ 125 CODE 39 PZN ..............................................................................................................................................................................125 Code 39 PZN Enable/Disable ..............................................................................
Contents ABC Codabar Enable/Disable .................................................................................................................................................................................. 157 ABC Codabar Concatenation Mode ...................................................................................................................................................................... 157 ABC Codabar Dynamic Concatenation Timeout .................................................
Contents China Sensible Code Set Length 2 ......................................................................................................................................................................... 193 Data Matrix .................................................................................................................................................................................................194 Data Matrix Enable / Disable ..........................................................
Contents Operating Mode ................................................................................................................................................................................................................................ 270 Digital Output .....................................................................................................................................................................................................................................
Contents NOTES 8 Gryphon™ I GFS4400
Chapter 1 Introduction About this Manual This Product Reference Guide (PRG) is provided for users seeking advanced technical information, including connection, programming, maintenance and specifications. The Quick Reference Guide (QRG) and other publications associated with this product are downloadable free of charge from the website listed on the back cover of this manual.
Introduction References Manual Conventions The following conventions are used in this document: The symbols listed below are used in this manual to notify the reader of key issues or procedures that must be observed when using the reader: Notes contain information necessary for properly diagnosing, repairing and operating the reader. The CAUTION symbol advises you of actions that could damage equipment or property.
About the Reader Introduction About the Reader The Gryphon GFS4400 is a fully self-contained standard range 2D bar code scanning module for use in OEM applications such as self service kiosks or other semi-automated equipment requiring the ability to read a bar code. It is intended to be an easy integration by system designers with little expertise in scanning technology.
Introduction Programming the Reader Datalogic Aladdin™ Programming can alternatively be performed using the Datalogic Aladdin™ Configuration application. Aladdin™ is a multi-platform utility program providing a quick and user-friendly configuration method via the RS-232/USB-COM interface. It communicates to the device through a user-friendly graphical interface running on a PC.
Chapter 2 Setup Unpacking Check carefully to ensure the reader and any accessories ordered are present and undamaged. If any damage occurred during shipment, contact Datalogic Technical Support. Information is shown on page 10. KEEP THE PACKAGING. Should the unit ever require service, it should be returned in its original shipping container. Setting Up the Reader Follow the steps provided in this section to connect and get your reader up and communicating with its host. 1.
Setup Attaching Reader to Host Attaching Reader to Host RS-232 Serial Connection Turn off power to the terminal/PC and connect the reader to the terminal/PC serial port via the RS-232 cable as shown in Figure 1. If the terminal will not support POT (Power Off the Terminal) to supply reader power, use the approved power supply (AC Adapter). Plug the AC Adapter barrel connector into the socket on the RS-232 cable connector and the AC Adapter plug into a standard power outlet. Figure 1.
Interface Selection Setup Interface Selection Since your scanner should have shipped with the correct interface cable (RS-232 or USB), the interface type should already be defined. If you need to change the interface type, go to Table 1 starting on page 16 and scan the appropriate bar code in that section.
Setup Interface Selection Table 1. Available Interfaces RS-232 FEATURES RS-232 standard interface Select RS232-STD $P,HA12,P(CR) RS-232 Wincor-Nixdorf Set RS-232 Interface Features starting on page 25 Select RS232-WN $P,HA13,P(CR) RS-232 for use with OPOS/UPOS/JavaPOS Select RS-232 OPOS $P,HA47,P(CR) USB Com to simulate RS-232 standard interface Select USB-COM-STDa a. Download the correct USB Com driver from www.adc.datalogic.
Interface Selection Setup KEYBOARD FEATURES $P,HA35,P(CR) USB Keyboard with standard key encoding Select USB Keyboard $P,HA2C,P(CR) USB Keyboard for Apple computers Set KEYBOARD Interface Features starting on page 37 Select USB-KBD-APPLE $P,HA2B,P(CR) USB Keyboard with alternate key encoding Select USB Alternate Keyboard Product Reference Guide 17
Setup Custom Configuration Settings Custom Configuration Settings Configure Interface Settings If your installation requires you to select options to customize your reader, turn to the appropriate section for your interface type in "Configuration Using Bar Codes" starting on page 21.
Custom Configuration Settings Setup Resetting the Product Configuration to Defaults Restore Custom Defaults If you aren’t sure what programming options are in your imager, or you’ve changed some options and want to restore the Custom Default Configuration that may have been saved in the scanner, scan the Restore Custom Default Configuration bar code below. This will restore the custom configuration for the currently active interface. Custom defaults are based on the interface type.
Setup Custom Configuration Settings NOTES 20 Gryphon™ I GFS4400
Chapter 3 Configuration Using Bar Codes This and following sections provide programming bar codes to configure your reader by changing the default settings. For details about additional methods of programming, see "Configuration Methods" on page 11. You must first enable your reader to read bar codes in order to use this section. If you have not done this, go to Setup, starting on page 13 and complete the appropriate procedure.
Enter/Exit Programming Mode You must first enable your reader to read bar codes in order to use this section. If you have not done this, go to Setup, starting on page 13 and complete the appropriate procedure. To program features: 1. Scan the ENTER/EXIT PROGRAMMING bar code, available at the top of each programming page, when applicable. 2. Scan the bar code to set the desired programming feature.
Enter/Exit Programming Mode GLOBAL INTERFACE FEATURES The following interface features are configurable by all interface types. Host Commands — Obey/Ignore This option specifies whether the reader will obey or ignore host commands. When set to ignore, the reader will ignore all host commands except for those necessary for: • service mode • flash programming mode • keeping the interface active • transmission of labels.
Enter/Exit Programming Mode NOTES 24 Gryphon™ I GFS4400
RS-232 ONLY INTERFACE BAUD RATE on page 26 DATA BITS on page 27 STOP BITS on page 27 PARITY on page 28 HANDSHAKING CONTROL on page 29 Use the programming bar codes in this section if modifications to the standard RS-232 interface settings are necessary to meet your system’s requirements. Additional settings which apply to both the RS-232 and USB interfaces are available in the next section, "RS232/USB-Com Interfaces" starting on page 30.
Enter/Exit Programming Mode RS-232 Only Interface Baud Rate See page 246 for information on this feature.
RS-232 Only Interface Enter/Exit Programming Mode Data Bits This parameter allows the reader to interface with devices requiring a 7-bit or 8-bit ASCII protocol for sending and receiving data. $CR2DA00(CR) 7 Data Bits $CR2DA01(CR) DEFAULT 8 Data Bits Stop Bits Set the number of stop bits to match host device requirements. See page 246 for more information on this feature.
Enter/Exit Programming Mode RS-232 Only Interface Parity This feature specifies parity required for sending and receiving data. Select the parity type according to host device requirements. See page 246 for more information.
RS-232 Only Interface Enter/Exit Programming Mode Handshaking Control See page 246 for more information about this feature.
RS-232/USB-COM INTERFACES INTERCHARACTER DELAY on page 31 BEEP ON ASCII BEL on page 31 BEEP ON NOT ON FILE on page 32 ACK NAK OPTIONS on page 32 ACK CHARACTER on page 33 NAK CHARACTER on page 33 ACK NAK TIMEOUT VALUE on page 34 ACK NAK RETRY COUNT on page 34 ACK NAK ERROR HANDLING on page 35 INDICATE TRANSMISSION FAILURE on page 35 DISABLE CHARACTER on page 36 ENABLE CHARACTER on page 36 The programming bar codes in this chapter allow modifications to the standard RS-232 and USB-Com interfaces.
RS-232/USB-Com Interfaces Enter/Exit Programming Mode Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay.
Enter/Exit Programming Mode RS-232/USB-Com Interfaces Beep On Not on File This option enables/disables the action of the reader to sound a three beep sequence upon receiving a Not-On-File (NOF) host command. $CBPNF00(CR) Beep On Not On File = Disable $CBPNF01(CR) DEFAULT Beep On Not On File = Enable ACK NAK Options This enables/disables the ability of the reader to support the RS-232 ACK/NAK protocol. See page 248 for more information.
RS-232/USB-Com Interfaces Enter/Exit Programming Mode ACK Character This setting specifies an ASCII character or hex value to be used as the ACK character. ASCII characters or any hex value from 0 to 0xFF can be selected. See page 248 for more information. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option Data Bits has been set as 7 Data Bits.
Enter/Exit Programming Mode RS-232/USB-Com Interfaces ACK NAK Timeout Value This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout. See page 250 for more information on setting this feature.
RS-232/USB-Com Interfaces Enter/Exit Programming Mode ACK NAK Error Handling This feature specifies the method the reader uses to handle receive errors detected while waiting for an ACK character from the host.
Enter/Exit Programming Mode RS-232/USB-Com Interfaces Disable Character Specifies the value of the RS-232 host command used to disable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8-bit data is not recognized when the option Data Bits has been set as 7 Data Bits. See page 252 for more information on setting this feature.
USB KEYBOARD SETTINGS COUNTRY MODE on page 38 SEND CONTROL CHARACTERS on page 42 INTERCODE DELAY on page 43 CAPS LOCK STATE on page 43 USB KEYBOARD SPEED on page 44 USB KEYBOARD NUMERIC KEYPAD on page 45 Use the programming bar codes in this chapter to select options for USB Keyboard Interface. Reference Appendix C, Standard Defaults for a listing of standard factory settings. Information about control character emulation which applies to keyboard interfaces is listed in Appendix G, Scancode Tables.
Enter/Exit Programming Mode USB Keyboard Settings Country Mode This feature specifies the country/language supported by the keyboard. Several languages are supported: $CKBCO00(CR) DEFAULT Country Mode = U.S. $CKBCO01(CR) Country Mode = Belgium $CKBCO02(CR) Country Mode = Britain $CKBCO11(CR) Supports only the interfaces listed in the Country Mode feature description. Country Mode = Croatia $CKBCO0E(CR) Supports only the interfaces listed in the Country Mode feature description.
USB Keyboard Settings Enter/Exit Programming Mode Country Mode (continued) $CKBCO04(CR) Country Mode = France $CKBCO13(CR) Supports only the interfaces listed in the Country Mode feature description. Country Mode = French Canadian $CKBCO05(CR) Country Mode = Germany $CKBCO0D(CR) Supports only the interfaces listed in the Country Mode feature description.
Enter/Exit Programming Mode USB Keyboard Settings Country Mode (continued) $CKBCO14(CR) Supports only the interfaces listed in the Country Mode feature description. Country Mode = Lithuanian $CKBCO07(CR) Country Mode = Norway $CKBCO12(CR) Supports only the interfaces listed in the Country Mode feature description. Country Mode = Poland $CKBCO08(CR) Supports only the interfaces listed in the Country Mode feature description.
USB Keyboard Settings Enter/Exit Programming Mode Country Mode (continued) $CKBCO09(CR) Country Mode = Spain $KBCO0A(CR) Country Mode = Sweden $CKBCO0B(CR) Supports only the interfaces listed in the Country Mode feature description.
Enter/Exit Programming Mode USB Keyboard Settings Send Control Characters This feature specifies how the reader transmits ASCII control characters to the host. Reference Appendix G, Scancode Tables for more information about control characters. Options are as follows: Control Character 00 : Characters from 00 to 0x1F are sent as control character Ctrl+Keys, special keys are located from 0x80 to 0xA1.
USB Keyboard Settings Enter/Exit Programming Mode Intercode Delay Specifies the delay between labels transmitted to the host for this interface. The selectable range for this feature is from 0 to 99 seconds. See page 254 in “References” for detailed information and examples for setting this feature. $CKBID Set Intercode Delay Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
Enter/Exit Programming Mode USB Keyboard Settings USB Keyboard Speed This option specifies the USB poll rate for a USB keyboard. This feature applies ONLY to the USB Keyboard interface.
USB Keyboard Settings Enter/Exit Programming Mode USB Keyboard Speed (continued) $CKBSP07(CR) USB Keyboard Speed = 7ms $CKBSP08(CR) USB Keyboard Speed = 8ms $CKBSP09(CR) USB Keyboard Speed = 9ms $CKBSP0A(CR) USB Keyboard Speed = 10ms USB Keyboard Numeric Keypad This option Controls whether numeric characters will be sent using standard keys or the numeric keypad.
Enter/Exit Programming Mode USB Keyboard Settings NOTES 46 Gryphon™ I GFS4400
USB-OEM INTERFACE USB-OEM DEVICE USAGE on page 48 TRANSMIT LABELS IN CODE 39 FORMAT on page 49 INTERFACE OPTIONS on page 49 Feature settings for USB interfaces differ depending upon which host type the reader will be connected with. Use the feature settings in this chapter to specifically configure for the USBOEM interface. Other USB interfaces are included in the appropriate chapter for their host type. Reference Appendix C for a listing of standard factory settings.
Enter/Exit Programming Mode USB-OEM Interface USB-OEM Device Usage The USB-OEM protocol allows for the reader to be identified as one of two different types of bar code scanners. Depending on what other scanners you may already have connected to a USB-OEM POS, you may need to change this setting to enable all devices to communicate. Options are: • Table Top Scanner • Handheld Scanner It may be necessary to switch device usage when connecting two readers/scanners of the same type to a POS system.
USB-OEM Interface Transmit Labels in Code 39 Format This feature enable/disables translation to Code 39 before transmitting label data to a USBOEM host. Only the symbology identifier is modified for the translation. The data is not converted to Code 39 or verified to be valid for Code 39.
USB-OEM Interface NOTES 50 Gryphon™ I GFS4400
DATA FORMAT GLOBAL PREFIX/SUFFIX on page 52 GLOBAL AIM ID on page 53 SET AIM ID INDIVIDUALLY FOR GS1-128 on page 55 LABEL ID starting on page 56 •Label ID: Pre-Loaded Sets •Individually Set Label ID •Label ID Control •Label ID Symbology Selection •Label ID Symbology Selection • 1D Symbologies • 2D Symbologies NO READ MESSAGE starting on page 63 NO READ STRING starting on page 63 CODE VERIFIER MODE starting on page 64 •Code Verifier Mode •Match String •Wrong Code String CASE CONVERSION on page 67 CHARACTE
Enter/Exit Programming Mode Data Format Global Prefix/Suffix This option sets up to 20 characters each from the set of ASCII characters or any hex value from 00 to FF. The characters may be added as a prefix (in a position before the bar code data, also called a header) and/or as a suffix (in a position following the bar code data, also called a footer). See page 257 for more detailed instructions on setting this feature.
Data Format Enter/Exit Programming Mode Global AIM ID This feature enables/disables addition of AIM IDs for all symbology types. AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned bar code data. See Table 2 on page 3-53 for a listing of AIM IDs. AIM label identifiers consist of three characters as follows: • A close brace character (ASCII ‘]’), followed by...
Enter/Exit Programming Mode DATABAR EXPANDED COMPOSITE DATABAR LIMITED DATABAR LIMITED COMPOSITE DATA MATRIX EAN128 EAN128 COMPOSITE EAN13 EAN13 P2 EAN13 P5 EAN13 COMPOSITE EAN8 EAN8 P2 EAN8 P5 EAN8 COMPOSITE FOLLET 2OF5 I2OF5 IATA INDUSTRIAL 2OF5 INDUSTRIAL 2OF5 ISBN ISBT128 CONCAT ISSN MAXICODE MICRO QR MICRO PDF MSI PDF417 PLESSEY POSTAL AUSTRALIAN POSTAL IMB POSTAL JAPANESE POSTAL KIX POSTAL PLANET POSTAL PORTUGAL POSTAL POSTNET BB POSTAL ROYAL MAIL POSTAL SWEDISH POSTNET QR CODE S25 TRIOPTIC UPCA UPCA
Data Format Enter/Exit Programming Mode Set AIM ID Individually for GS1-128 This feature configures a Label ID individually for the GS1-128 symbology and the programming for this works the same way as Label ID. See Label ID: Set Individually Per Symbology, starting on page 262 for detailed instructions on setting this feature.
Data Format Label ID A Label ID is a customizable code of up to three ASCII characters (convert to Hex using the ASCII Chart on the inside back cover of this manual), used to identify a bar code symbology type. It can be appended previous to or following the transmitted bar code data depending upon how this option is enabled. This feature provides options for configuring custom Label IDs or individually per symbology (see "Individually Set Label ID" on page 57).
Data Format Enter/Exit Programming Mode Individually Set Label ID This feature configures a Label ID individually for a single symbology. To set, first define whether you want it as a prefix or suffix by scanning a label below. Then turn to Label ID Symbology Selection • 1D Symbologies, starting on page 58 to select the symbology you want to set, followed by up to 3 characters from the ASCII Chart at the back of this manual.
Enter/Exit Programming Mode Data Format Label ID Symbology Selection − 1D Symbologies This option selects the symbology for which a Label ID is to be configured. See "Label ID" on page 56 or page 262 in “References” for more detailed instructions. If less than the expected string of 3 characters are selected, scan the ENTER/ EXIT bar code twice to accept the selection and exit Programming Mode.
Data Format Enter/Exit Programming Mode Label ID Symbology Selection − 1D Symbologies (continued) $CCCID Set Code 39 CIP Label ID Character(s) $C8BID Set EAN 8 Label ID Character(s) $C8MID Set EAN 8 Composite Label ID Character(s) $C82ID Set EAN 8 P2 Label ID Character(s) $C85ID Set EAN 8 P5 Label ID Character(s) $CF2ID Set Follett 2 of 5 Label ID Character(s) $C4BID Set GS1 DataBar 14 Label ID Character(s) $C4CID Set GS1 DataBar 14 Composite Label ID Character(s) Product Reference Guide $C35I
Enter/Exit Programming Mode Data Format Label ID Symbology Selection − 1D Symbologies (continued) $CXBID Set GS1 DataBar Expanded Label ID Character(s) $CIAID Set IATA Industrial 2 of 5 Label ID Character(s) $CPMID Set IMB Postal Code Label ID Character(s) $CU2ID Set Industrial 2 of 5 Label ID Character(s) $CI2ID Set Interleaved 2 of 5 Label ID Character(s) $CISID Set ISBN Label ID Character(s) $CINID Set ISSN Label ID Character(s) $CPJID Set Japan Postal Code Label ID Character(s) 60 $CGBID S
Data Format Enter/Exit Programming Mode Label ID Symbology Selection − 1D Symbologies (continued) $CPZID Set PZN Code Label ID Character(s) $CPBID Set Postnet BB Label ID Character(s) $CPRID $CAMID Set Royal Postal Code Label ID Character(s) Set UPC-A Composite Label ID Character(s) $CS2ID $CA2ID Set Standard 2 of 5 Label ID Character(s) $CPSID Set Swedish Postal Code Label ID Character(s) $CCTID Set Trioptic Code Label ID Character(s) $CABID Set UPC-A Label ID Character(s) Product Reference
Enter/Exit Programming Mode Data Format Label ID Symbology Selection − 2D Symbologies $CAZID Set Aztec Label ID Character(s) $CCSID Set China Sensible Label ID Character(s) $CCFID Set Codablock F Label ID Character(s) $CDMID Set Data Matrix Label ID Character(s) $CMXID Set Maxicode Label ID Character(s) $CP4ID Set PDF 417 Label ID Character(s) $CMIID Set Micro PDF 417 Label ID Character(s) $CQRID Set QR Code Label ID Character(s) $CMQID Set Micro QR Label ID Character(s) 62 Gryphon™ I GFS4400
Data Format Enter/Exit Programming Mode No Read Message This feature Enables/Disables the No Read Message feature. When Disabled, nothing is sent if the trigger is pressed and released when no code has been decoded during a reading phase. Otherwise, the No Read String is sent.
Enter/Exit Programming Mode Data Format CODE VERIFIER This feature allows the scanner to verify that all codes read and decoded match a defined string saved in its memory. It is valid when in On Line, Serial On Line, Automatic and Automatic (Object Sense) Operating Modes. If the code read matches the code verifier Match String, then it is sent to the host through the configured port.
Data Format Enter/Exit Programming Mode Match String This feature allows you to define the string to be used as the match code for Code Verification. The Match String must be configured to include start/stop characters and check digits if their transmission is enabled. See "Match String" on page 265 in References for more information. It is possible to define the Match string by inserting: • all printable characters • non printable ASCII characters No wild card characters are supported.
Enter/Exit Programming Mode Data Format Label Transmit Mode Specifies whether the decoded label must be transmitted to the host as it has been decoded or after the reading phase has been deactivated (Phase Off). $CLFTX00\r Phase Off $CLFTX01\r DEFAULT On Decode Advanced Formatting: User Label Edit Advanced formatting is available to create user label edit scripts. See the Datalogic Aladdin configuration application or contact Technical Support.
Data Format Enter/Exit Programming Mode Case Conversion This feature allows conversion of the case of all alphabetic characters to upper or lower case. Case conversion affects ONLY scanned bar code data, and does not affect Label ID, Prefix, Suffix, or other appended data.
Enter/Exit Programming Mode Data Format NOTES 68 Gryphon™ I GFS4400
DIGITAL OUTPUT Digital Output only pertains to the GFS4450-9 RS232 interface. ACTIVATION EVENT on page 70 DEACTIVATION EVENT on page 71 DEACTIVATION TIMEOUT on page 71 ACTIVATION STATE on page 72 See “References” starting on page 256 for more information about Digital Output. Use the programming barcodes in this chapter to select options for Digital Outputs. Reference Appendix C, for a listing of standard factory settings.
Enter/Exit Programming Mode Digital Output Activation Event Defines the event activating the output.
Digital Output Enter/Exit Programming Mode Deactivation Event Defines the event deactivating the output. See "Wrong Code String" on page 266 in “References” for more information about this feature. $COUD100\r DEFAULT Disable $COUD101\r Timeout $COUD102\r Reading Phase Active Deactivation Timeout When Timeout is the selected Deactivation Event, this specifies the maximum duration of the output pulse.
Enter/Exit Programming Mode Digital Output Activation State Determines the active state of the output.
READING PARAMETERS DOUBLE READ TIMEOUT on page 74 GOOD READ BEEP FREQUENCY on page 76 LED AND BEEPER INDICATORS on page 75 GOOD READ BEEP LENGTH on page 77 POWER ON ALERT on page 75 GOOD READ BEEP VOLUME on page 78 GOOD READ: WHEN TO INDICATE on page 75 GOOD READ LED DURATION on page 79 GOOD READ BEEP TYPE on page 76 SCANNING FEATURES OPERATING MODE on page 80 AIMING POINTER on page 86 PHASE OFF EVENT on page 81 AIMING DURATION TIMER on page 87 PHASE OFF TIMEOUT on page 81 GREEN SPOT DURATION on
Enter/Exit Programming Mode Reading Parameters Double Read Timeout Double Read Timeout specifies the minimum time between consecutive good reads of labels of the same symbology and data. This prevents a double read of the same label. If the unit reads a label and sees the same label again within the specified timeout, the second read is ignored. Double Read Timeout does not apply to scan modes that require a trigger pull for each label read.
Reading Parameters Enter/Exit Programming Mode LED AND BEEPER INDICATORS Power On Alert Disables or enables the indication (from the Beeper) that the reader is receiving power. $CBPPU00(CR) Power On Alert = Disable (No Audible Indication) $CBPPU01(CR) DEFAULT Power On Alert = Power-up Beep Good Read: When to Indicate This feature specifies when the reader will provide indication (beep and/or flash its green LED) upon successfully reading a bar code.
Enter/Exit Programming Mode Reading Parameters Good Read Beep Type Specifies whether the good read beep has a mono or bitonal beep sound. $CBPTY00(CR) DEFAULT Good Read Beep Type = Mono $CBPTY01(CR) Good Read Beep Type = Bitonal Good Read Beep Frequency Adjusts the good read beep to sound at a selectable low, medium or high frequency, selectable from the list below. (Controls the beeper’s pitch/tone.
Reading Parameters Enter/Exit Programming Mode Good Read Beep Length $CBPLE06(CR) Good Read Beep Length = 60 msec $CBPLE08(CR) DEFAULT Good Read Beep Length = 80 msec $CBPLE0A(CR) Good Read Beep Length = 100 msec $CBPLE0C(CR) Good Read Beep Length = 120 msec $CBPLE0E(CR) Good Read Beep Length = 140 msec $CBPLE10(CR) Good Read Beep Length = 160 msec $CBPLE12(CR) Good Read Beep Length = 180 msec $CBPLE14(CR) Good Read Beep Length = 200 msec Product Reference Guide 77
Enter/Exit Programming Mode Reading Parameters Good Read Beep Volume Selects the beeper volume (loudness) upon a good read beep. There are three selectable volume levels.
Reading Parameters Enter/Exit Programming Mode Good Read LED Duration This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 100 milliseconds to 25,500 milliseconds (0.1 to 25.5 seconds) in 100ms increments. A setting of 00 keeps the LED on until the next trigger push. See page 269 in “References” for detailed instructions and examples for setting this feature.
Enter/Exit Programming Mode Reading Parameters SCANNING FEATURES Operating Mode Selects the reader’s scan operating mode. See page 270 in “References” for descriptions.
Reading Parameters Enter/Exit Programming Mode Phase Off Event $CSPTO00\r DEFAULT Trigger Stop $CSPTO01\r Timeout $CSPTO02\r Trigger Stop - Timeout Phase Off Timeout Timeout can be set within a range of 1second to 255 seconds in 1 second intervals. $CSNET Scanning Active Time Make a mistake? Scan the CANCEL barcode to abort and not save the entry string. You can then start again at the beginning.
Enter/Exit Programming Mode Reading Parameters Serial Start Character See page 270 in “References” for more information. To configure this feature scan the ENTER/EXIT PROGRAMMING MODE barcode above, then the barcode at left, followed by the digits (in hex) from the Alphanumeric characters in Appendix E, Keypad representing your desired character(s). End by scanning the ENTER/EXIT barcode again.
Reading Parameters Enter/Exit Programming Mode Presentation Mode Indication This operation is useful for indicating when the reader is in Automatic/Triggered Object Sense Operating Mode. If enabled, the blue indicator will blink when Presentation Mode scanning is active. $CSMFL00(CR) DEFAULT Presentation Mode Indication = Disable $CSMFL01(CR) Presentation Mode Indication = Enable Manual Trigger Control This feature is available in Serial On Line mode only.
Enter/Exit Programming Mode Reading Parameters Central Code Only Specifies the ability of the reader to decode labels only when they are close to the center of the aiming pattern. This allows the reader to accurately target labels when they are placed close together, such as on a pick sheet. See Appendix B, Aimer Calibration starting on page 287 for information about setting the aiming coordinates. This feature is not compatible with Multiple Labels Reading in a Volume.
Reading Parameters Enter/Exit Programming Mode Illumination On Time Defines the amount of time illumination is kept ON after a label is decoded. If an object is detected before Illumination ON expires, the timer is refreshed with the Object Gone timeout value. Range is 0 millisecond to 25.5 milliseconds in 100 millisecond intervals. This configuration is available in Automatic (Object Sense) only.
Enter/Exit Programming Mode Reading Parameters Presentation Illumination Control Controls the illumination status while the reading mode is Automatic Trigger Object Sense Operating Mode and the reader is attempting to detect objects. $CSMIL00(CR) DEFAULT Illumination Control = OFF $CSMIL01(CR) Illumination Control = ON $CSMIL02(CR) Illumination Control = Dim Aiming Pointer Enables/disables the aiming pointer for all symbologies.
Reading Parameters Enter/Exit Programming Mode Aiming Duration Timer Specifies the frame of time the aiming pointer remains on after decoding a label, when in On Line or Serial On Line mode.The range for this setting is from 1 to 255 seconds in 1-second increments. See page 273 in “References” for a description of this feature. LSTM00 DEFAULT Aiming Off After Decoding LSTM Set Aiming Duration Timer Make a mistake? Scan the CANCEL bar code to abort and not save the entry string.
Enter/Exit Programming Mode Reading Parameters Mobile Phone Mode This mode is useful for scanning bar codes displayed on a mobile phone. Other options for this feature can be configured using the Datalogic Aladdin application. $CSNPE00(CR) Mobile Phone Mode = Disable $CSNPE01(CR) DEFAULT Mobile Phone Mode = Enable Mobile Bias This variable mode alters scan module operation, optimizing barcode scanning for reading from mobile device displays rather than standard labels.
Reading Parameters Enter/Exit Programming Mode Partial Label Reading Control Enable/Disable the option to ignore partial labels to be read within the boundary of the field of view. IPPL00 Partial Label Reading Control = Disable IPPL01 DEFAULT Partial Label Reading Control = Enable Mirror Reading Mode Enable/Disable the ability to decode the mirror image of a bar code label. This feature pertains mainly to 2D barcodes: Data Matrix, Maxicode, QR Code Aztec and PDF-417.
Enter/Exit Programming Mode Reading Parameters Decode Negative Image Enable/Disable the ability to decode a negative image for all symbologies. When this feature is enabled, you will be unable to read normally-printed labels or programming labels in this manual. Scan the “Disable” bar code below to return the scanner to its default for this feature. To set the reader to decode only 2D codes, go to "2D Normal/Inverse Symbol Control" on page 187.
Reading Parameters MULTIPLE LABEL READING When the reader’s aiming system is activated by a trigger push or other method (depending on the mode), it then acquires and processes each image in the area in front of it (the Volume). In this case, the scanner stops processing the image once it decodes a label. If several labels are present in the volume, only the first label encountered is decoded and sent.
Reading Parameters Multiple Labels Ordering by Code Symbology This feature allows you to specify the order multiple labels are transmitted by symbology type, when Multiple Labels per Frame is enabled. See page 274 in “References” for detailed information on setting this feature. $CSNMS Select Symbologies for Multiple Labels Ordering Make a mistake? Scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning.
SYMBOLOGIES 1D Code Selection The reader supports the following 1D symbologies (bar code types). See "2D Symbologies" starting on page 185 for 2D bar codes. Symbology-dependent options are included in each chapter.
Enter/Exit Programming Mode Symbologies DISABLE ALL SYMBOLOGIES Use this feature to disable all symbologies. 1. Scan the ENTER/EXIT PROGRAMMING Mode bar code. 2. Scan the Disable All Symbologies bar code. 3. Complete the programming sequence by scanning the ENTER/EXIT PROGRAMMING bar code. $AD(CR) Disable All Symbologies This does not disable the reading of programming labels.
Symbologies Enter/Exit Programming Mode CODE EAN/UPC Coupon Control This feature is used to control the reader’s method of processing coupon labels.
Enter/Exit Programming Mode Symbologies UPC-A The following options apply to the UPC-A symbology. UPC-A Enable/Disable When disabled, the reader will not read UPC-A bar codes. $CABEN00(CR) UPC-A = Disable $CABEN01(CR) DEFAULT UPC-A = Enable UPC-A Check Character Transmission Enable this option to transmit the check character along with UPC-A bar code data.
Symbologies Enter/Exit Programming Mode Expand UPC-A to EAN-13 Expands UPC-A data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. $CAB3B00(CR) DEFAULT UPC-A to EAN-13 = Don’t Expand $CAB3B01(CR) UPC-A to EAN-13 = Expand UPC-A Number System Character Transmission This feature enables/disables transmission of the UPC-A number system character.
Enter/Exit Programming Mode Symbologies UPC-A 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label of this symbology is decoded. $CAB2D00(CR) DEFAULT EAN-13 2D Component = Disable (2D component not required) $CAB2D01(CR) EAN-13 2D Component = 2D component must be decoded UPC-E The following options apply to the UPC-E symbology. UPC-E Enable/Disable When disabled, the reader will not read UPC-E bar codes.
Symbologies Enter/Exit Programming Mode UPC-E Check Character Transmission Enable this option to transmit the check character along with UPC-E bar code data. $CEBCT00(CR) UPC-E Check Character Transmission = Don’t Send $CEBCT01(CR) DEFAULT UPC-E Check Character Transmission = Send UPC-E 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label for this symbology is decoded.
Enter/Exit Programming Mode Symbologies Expand UPC-E to EAN-13 Expands UPC-E data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. $CEB3B00(CR) DEFAULT UPC-E to EAN-13 = Don’t Expand $CEB3B01(CR) UPC-E to EAN-13 = Expand Expand UPC-E to UPC-A Expands UPC-E data to the UPC-A data format.
Symbologies Enter/Exit Programming Mode UPC-E Number System Character Transmission This feature enables/disables transmission of the UPC-E system number character. $CEBNS00(CR) UPC-E Number System Character = Do not transmit $CEBNS01(CR) DEFAULT UPC-E Number System Character = Transmit GTIN FORMATTING This feature enables/disables the ability to convert UPC-E, UPC-A, EAN 8, and EAN 13 labels into the GTIN 14-character format.
Enter/Exit Programming Mode Symbologies EAN 13 (JAN 13) The following options apply to the EAN 13 (Jan 13) symbology. EAN 13 Enable/Disable When disabled, the reader will not read EAN 13/JAN 13 bar codes. $C3BEN00(CR) EAN 13 = Disable $C3BEN01(CR) DEFAULT EAN 13 = Enable EAN 13 Check Character Transmission Enable this option to transmit the check character along with EAN 13 bar code data.
Symbologies Enter/Exit Programming Mode EAN-13 Flag 1 Character Enables/disables transmission of an EAN/JAN13 Flag1 character. The Flag 1 character is the first character of the label. $C3BF100(CR) EAN-13 Flag 1 Char= Don’t transmit $C3BF101(CR) DEFAULT EAN-13 Flag 1 Char= Transmit EAN-13 ISBN Conversion This option enables/disables conversion of EAN 13/JAN 13 Bookland labels starting with 978 to ISBN labels.
Enter/Exit Programming Mode Symbologies EAN-13 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label of this symbology is decoded. $C3B2D00(CR) DEFAULT EAN-13 2D Component = Disable (2D component not required) $C3B2D01(CR) EAN-13 2D Component = 2D component must be decoded ISSN The following options apply to the ISSN symbology. ISSN Enable/Disable Enables/disables conversion of EAN/JAN13 Bookland labels starting with 977 to ISSN labels.
Symbologies Enter/Exit Programming Mode EAN 8 (JAN 8) The following options apply to the EAN 8 (Jan 8) symbology. EAN 8 Enable/Disable When disabled, the reader will not read EAN 8/JAN 8 bar codes. $C8BEN00(CR) EAN 8 = Disable $C8BEN01(CR) DEFAULT EAN 8 = Enable EAN 8 Check Character Transmission Enable this option to transmit the check character along with EAN 8 bar code data.
Enter/Exit Programming Mode Symbologies Expand EAN 8 to EAN 13 Enable this option to expand EAN 8/JAN 8 labels to EAN 13/JAN 13. $C8B3B00(CR) DEFAULT Expand EAN 8 to EAN 13 = Disable $C8B3B01(CR) Expand EAN 8 to EAN 13 = Enable EAN 8 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label for this symbology is decoded.
Symbologies Enter/Exit Programming Mode UPC/EAN GLOBAL SETTINGS This section provides configuration settings for UPC-A, UPC-E, EAN 13 and EAN 8 symbologies, and affects all of these unless otherwise marked for each feature description. UPC/EAN Price Weight Check This feature enables/disables calculation and verification of price/weight check digits.
Enter/Exit Programming Mode Symbologies UPC/EAN Quiet Zones This feature specifies the number of quiet zones for UPC/EAN labels. Quiet zones are blank areas at the ends of a bar code, typically 10 times the width of the narrowest bar or space in the label. The property applies to all EAN-UPC symbologies globally and to the ADDONs.
Symbologies Enter/Exit Programming Mode ADD-ONS Contact Customer Support for advanced programming of optional and conditional add-ons. Optional Add-ons The reader can be enabled to optionally read the following add-ons (supplementals): If a UPC/EAN base label and an add-on are both decoded, the reader will transmit the base label and add-on. If a UPC/EAN base label is decoded without an add-on, the base label will be transmitted without an add-on.
Enter/Exit Programming Mode Symbologies Optional Add-On Timer This option sets the time the reader will look for an add-on when an add-on fragment has been seen and optional add-ons are enabled. (Also see "Optional GS1-128 Add-On Timer" on page 113.
Symbologies Enter/Exit Programming Mode Optional Add-On Timer — cont.
Enter/Exit Programming Mode Symbologies Optional Add-On Timer — cont.
Symbologies Enter/Exit Programming Mode Optional GS1-128 Add-On Timer This option sets the timer expiration value to read the added part after reading the linear EAN/ UPC part. For UPC/EAN add-ons other than those of that type, see "Optional Add-On Timer" on page 110.
Enter/Exit Programming Mode Symbologies Optional GS1-128 Add-On Timer — cont.
Symbologies Enter/Exit Programming Mode Optional GS1-128 Add-On Timer — cont.
Enter/Exit Programming Mode Symbologies CODE 39 The following options apply to the Code 39 symbology. Code 39 Enable/Disable $CC3EN00(CR) Code 39 = Disable $CC3EN01(CR) DEFAULT Code 39 = Enable Code 39 Check Character Calculation Enable this option to enables/disables calculation and verification of an optional Code 39 check character.
Symbologies Enter/Exit Programming Mode Code 39 Check Character Calculation — cont. $CC3CC04(CR) Code 39 Check Character Calculation = Enable Italian Post Check $CC3CC08(CR) Code 39 Check Character Calculation = Enable Daimler Chrysler Check Code 39 Check Character Transmission Enable this option to transmit the check character along with Code 39 bar code data.
Enter/Exit Programming Mode Symbologies Code 39 Start/Stop Character Transmission Enable this option to enable/disable transmission of Code 39 start and stop characters. $CC3SS00(CR) DEFAULT Code 39 Start/Stop Character Transmission = Don’t Transmit $CC3SS01(CR) Code 39 Start/Stop Character Transmission = Transmit Code 39 Full ASCII Enables/disables the translation of Code 39 characters to Code 39 full-ASCII characters.
Symbologies Enter/Exit Programming Mode Code 39 Quiet Zones This feature specifies the number of quiet zones for Code 39 labels. Quiet zones are blank areas at the ends of a bar code, typically 10 times the width of the narrowest bar or space in the label.
Enter/Exit Programming Mode Symbologies Code 39 Set Length 1 This feature specifies one of the bar code lengths for Code 39 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only. The length can be set from 0 to 50 characters. Table 3 provides examples for setting Length 1. See page 255 for detailed instructions on setting this feature. Table 3.
Symbologies Enter/Exit Programming Mode Code 39 Set Length 2 This feature specifies one of the bar code lengths for Code 39 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. Table 4 provides examples for setting Length 2. See page 255 for detailed instructions on setting this feature. Table 4.
Enter/Exit Programming Mode Symbologies TRIOPTIC CODE The following options apply to the Trioptic symbology. Trioptic Code Enable/Disable $CCTEN00(CR) DEFAULT Trioptic Code = Disable $CCTEN01(CR) Trioptic Code = Enable CODE 32 (ITAL PHARMACEUTICAL CODE) The following options apply to the Code 32 (Italian Pharmaceutical Code) symbology. Code 32 Enable/Disable When disabled, the reader will not read Code 32 bar codes.
Symbologies Enter/Exit Programming Mode Code 32 Feature Setting Exceptions The following features are set for Code 32 by using these Code 39 settings: "Code 39 Quiet Zones" on page 119 "Code 39 Length Control" on page 119 "Trioptic Code" on page 122 Code 32 Check Char Transmission Enable this option to transmit the check character along with Code 32 bar code data.
Enter/Exit Programming Mode Symbologies CODE 39 CIP (FRENCH PHARMACEUTICAL) The following options apply to the Code 39 CIP symbology. Code 39 CIP Enable/Disable Enables/Disables ability of the reader to decode Code 39 CIP labels. $CCCEN00(CR) DEFAULT Code 39 CIP = Disable $CCCEN01(CR) Code 39 CIP = Enable CODE 39 DANISH PPT The following options apply to the Code 39 Danish PPT symbology. Code 39 Danish PPT Enable/Disable Enables/Disables AIM ID for Code 39 Danish PPT Codes.
Symbologies Enter/Exit Programming Mode CODE 39 LAPOSTE The following options apply to the Code 39 LaPoste symbology. Code 39 LaPoste Enable/Disable Enables/disables the ability of the scanner to decode Code39 La Poste labels. $CLPEN00(CR) DEFAULT Code 39 LaPoste = Disable $CLPEN01(CR) Code 39 LaPoste = Enable CODE 39 PZN The following options apply to the Code 39 PZN symbology. Code 39 PZN Enable/Disable Enables/disables the ability of the scanner to decode Code39 PZN labels.
Enter/Exit Programming Mode Symbologies CODE 128 The following options apply to the Code 128 symbology. Code 128 Enable/Disable When disabled, the reader will not read Code 128 bar codes. $CC8EN00(CR) Code 128 = Disable $CC8EN01(CR) DEFAULT Code 128 = Enable Expand Code 128 to Code 39 This feature enables/disables expansion of Code 128 labels to Code 39 labels.
Symbologies Enter/Exit Programming Mode Code 128 Check Character Transmission Enable this option to transmit the check character along with Code 128 bar code data. $CC8CT00(CR) DEFAULT Code 128 Check Character Transmission = Don’t Send $CC8CT01(CR) Code 128 Check Character Transmission = Send Code 128 Function Character Transmission Enables/disables transmission of Code128 function characters 1, 2, 3, and 4.
Enter/Exit Programming Mode Symbologies Code 128 Sub-Code Exchange Transmission Enables/disables the transmission of “Sub-Code Exchange” characters (NOT transmitted by standard decoding). $CC8SC00(CR) DEFAULT Code 128 Sub-Code Exchange Transmission = Disable $CC8SC01(CR) Code 128 Sub-Code Exchange Transmission = Enable Code 128 Quiet Zones This feature specifies the number of quiet zones for Code 128 labels.
Symbologies Enter/Exit Programming Mode Code 128 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 128 symbology. See page 255 for more information.
Enter/Exit Programming Mode Symbologies Code 128 Set Length 1 Specifies one of the bar code lengths for Code 128 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only. The length can be set from 1 to 80 characters. Table 5 provides some examples for setting Length 1. See page 255 for detailed instructions on setting this feature. Table 5.
Symbologies Enter/Exit Programming Mode Code 128 Set Length 2 This feature specifies one of the bar code lengths for Code 128 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only. The length can be set from 1 to 80 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 6 provides examples for setting Length 2.
Enter/Exit Programming Mode Symbologies GS1-128 The following options apply to the GS1-128 symbology. (Also known as USS-128, GS1-128, GTIN-128, UCC-128, EAN-128.) GS1-128 Enable This option enables/disables the ability of the reader to translate GS1-128 labels to the GS1-128 data format. Options are: • Transmit GS1-128 labels in Code 128 data format. • Transmit GS1-128 labels in GS1-128 data format. • Do not transmit GS1-128 labels.
Symbologies Enter/Exit Programming Mode CODE ISBT 128 The following options apply to the ISBT 128 symbology. ISBT 128 Concatenation Use this option to enable/disable ISBT128 concatenation of 2 labels. $CI8CE00(CR) DEFAULT ISBN 128 Concatenation = Disable $CI8CE01(CR) ISBN 128 Concatenation = Enable ISBT 128 Force Concatenation When enabled, this feature forces concatenation for ISBT. This option is only valid when ISBT 128 Concatenation is enabled.
Enter/Exit Programming Mode Symbologies ISBT 128 Concatenation Mode Specifies the concatenation mode between Static and Dynamic. This option is only valid when ISBT 128 Concatenation is enabled (see "ISBT 128 Concatenation" on page 133).
Symbologies Enter/Exit Programming Mode ISBT 128 Dynamic Concatenation Timeout Specifies the timeout used by the ISBT 128 Dynamic Concatenation Mode.
Enter/Exit Programming Mode Symbologies INTERLEAVED 2 OF 5 (I 2 OF 5) The following options apply to the I 2 of 5 symbology. I 2 of 5 Enable/Disable When disabled, the reader will not read I 2 of 5 bar codes.
Symbologies Enter/Exit Programming Mode I 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional I 2 of 5 check character. Combinations of these settings are possible via the Aladdin configuration utility, or contact Technical Support.
Enter/Exit Programming Mode Symbologies I 2 of 5 Check Character Transmission Enable this option to transmit the check character along with I 2 of 5 bar code data. $CI2CT00(CR) I 2 of 5 Check Character Transmission = Don’t Send $CI2CT01(CR) DEFAULT I 2 of 5 Check Character Transmission = Send I 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the I 2 of 5 symbology.
Symbologies Enter/Exit Programming Mode I 2 of 5 Set Length 1 This feature specifies one of the bar code lengths for I 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. The length includes the bar code’s check and data characters. The length can be set from 2 to 50 characters in increments of two. Table 7 provides some examples for setting Length 1. See page 255 for detailed instructions on setting this feature.
Enter/Exit Programming Mode Symbologies I 2 of 5 Set Length 2 This feature specifies one of the bar code lengths for I 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The length includes the bar code’s check and data characters. The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 8 provides examples for setting Length 2.
Symbologies Enter/Exit Programming Mode INTERLEAVED 2 OF 5 CIP HR The following options apply to the Interleaved 2 of 5 CIP HR symbology. Interleaved 2 of 5 CIP HR Enable/Disable Enables/Disables ability of reader to decode Interleaved 2 of 5 CIP HR labels. $CCHEN00(CR) DEFAULT Interleaved 2 of 5 CIP HR = Disable $CCHEN01(CR) Interleaved 2 of 5 CIP HR = Enable FOLLETT 2 OF 5 The following options apply to the Follett 2 of 5 symbology.
Enter/Exit Programming Mode Symbologies STANDARD 2 OF 5 The following options apply to the Standard 2 of 5 symbology. Standard 2 of 5 Enable/Disable When disabled, the reader will not read Standard 2 of 5 bar codes. $C2SEN00(CR) DEFAULT Standard 2 of 5 = Disable $C2SEN01(CR) Standard 2 of 5 = Enable Standard 2 of 5 Check Character Calculation This option enables/disables calculation and verification of an optional Standard 2 of 5 check character.
Symbologies Enter/Exit Programming Mode Standard 2 of 5 Check Character Transmission This feature enables/disables transmission of an optional Standard 2 of 5 check character. $CS2CT00(CR) Standard 2 of 5 Check Character Transmission = Don’t Send $CS2CT01(CR) DEFAULT Standard 2 of 5 Check Character Transmission = Send Standard 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Standard 2 of 5 symbology.
Enter/Exit Programming Mode Symbologies Standard 2 of 5 Set Length 1 This feature specifies one of the bar code lengths for Standard 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s check and data characters. The length can be set from 1 to 50 characters. Table 9 provides some examples for setting Length 1. See page 255 if you want detailed instructions on setting this feature. Table 9.
Symbologies Enter/Exit Programming Mode Standard 2 of 5 Set Length 2 This feature specifies one of the bar code lengths for Standard 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check and data characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 10 provides examples for setting Length 2.
Enter/Exit Programming Mode Symbologies INDUSTRIAL 2 OF 5 The following options apply to the Industrial 2 of 5 symbology. Industrial 2 of 5 Enable/Disable Enables/Disables ability of reader to decode Industrial 2 of 5 labels. $CU2EN00(CR) DEFAULT Industrial 2 of 5 = Disable $CU2EN01(CR) Industrial 2 of 5 = Enable Industrial 2 of 5 Check Character Calculation Enables/Disables calculation and verification of an optional Industrial 2 of 5 check character.
Symbologies Enter/Exit Programming Mode Industrial 2 of 5 Check Character Transmission Enables/disables transmission of an Industrial 2 of 5 check character. $CU2CT00(CR) Industrial 2 of 5 Check Character Transmission = Disable $CU2CT01(CR) DEFAULT Industrial 2 of 5 Check Character Transmission = Enable Industrial 2 of 5 Length Control This feature specifies either variable length decoding or fixed length decoding for the Industrial 2 of 5 symbology.
Enter/Exit Programming Mode Symbologies Industrial 2 of 5 Set Length 1 This feature specifies one of the bar code lengths for Industrial 2 of 5 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only. The length can be set from 0 to 50 characters. Table 11 provides some examples for setting Length 1. See page 255 if you want detailed instructions on setting this feature.
Symbologies Enter/Exit Programming Mode Industrial 2 of 5 Set Length 2 This feature specifies one of the bar code lengths for Industrial 2 of 5 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters.
Enter/Exit Programming Mode Symbologies CODE IATA The following options apply to the IATA symbology. IATA Enable/Disable Enables/Disables the ability of the reader to decode IATA labels. $CIAEN00(CR) DEFAULT IATA = Disable $CIAEN01(CR) IATA = Enable IATA Check Character Transmission Enables/Disables calculation and verification of an optional Industrial 2 of 5 check character.
Symbologies Enter/Exit Programming Mode CODABAR The following options apply to the Codabar symbology. Codabar Enable/Disable When disabled, the reader will not read Codabar bar codes. $CCBEN00(CR) DEFAULT Codabar = Disable $CCBEN01(CR) Codabar = Enable Codabar Check Character Calculation Enable this option to enables/disables calculation and verification of an optional Codabar check character.
Enter/Exit Programming Mode Symbologies Codabar Check Character Transmission Enable this option to transmit the check character along with Codabar bar code data. $CCBCT00(CR) Codabar Check Character Transmission = Don’t Send $CCBCT01(CR) DEFAULT Codabar Check Character Transmission = Send Codabar Start/Stop Character Transmission Enable this option to enable/disable transmission of Codabar start and stop characters.
Symbologies Enter/Exit Programming Mode Codabar Start/Stop Character Set This option specifies the format of transmitted Codabar start/stop characters. $CCBSC00(CR) Codabar Check Character Set = ABCD/TN*E $CCBSC01(CR) Codabar Check Character Set = ABCD/ABCD $CCBSC02(CR) Codabar Check Character Set = abcd/tn*e $CCBSC03(CR) DEFAULT Codabar Check Character Set = abcd/abcd Codabar Start/Stop Character Match When enabled, this option requires that start and stop characters match.
Enter/Exit Programming Mode Symbologies Codabar Quiet Zones Specifies the number of quiet zones for Codabar labels. Quiet zones are blank areas at the ends of a bar code and are typically 10 times the width of the narrowest bar or space in the label.
Symbologies Enter/Exit Programming Mode Codabar Set Length 1 This feature specifies one of the bar code lengths for Codabar Length ControlCodabar Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s start, stop, check and data characters. The length must include at least one data character. The length can be set from 3 to 50 characters. Table 13 provides some examples for setting Length 1.
Enter/Exit Programming Mode Symbologies Codabar Set Length 2 This feature specifies one of the bar code lengths for Codabar Length ControlCodabar Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. The length includes the bar code’s start, stop, check and data characters. The length must include at least one data character. The length can be set from 3 to 50 characters.
Symbologies Enter/Exit Programming Mode ABC CODABAR The following options apply to the ABC Codabar symbology. ABC Codabar Enable/Disable Enables/Disables ability of reader to decode ABC Codabar labels. $CCBAB00(CR) DEFAULT ABC Codabar = Disable $CCBAB01(CR) ABC Codabar = Enable ABC Codabar Concatenation Mode Specifies the concatenation mode between Static and Dynamic.
Enter/Exit Programming Mode Symbologies ABC Codabar Dynamic Concatenation Timeout Specifies the timeout in 10-millisecond ticks used by the ABC Codabar Dynamic Concatenation Mode.
Symbologies Enter/Exit Programming Mode ABC Codabar Force Concatenation Forces labels starting or ending with D to be concatenated.
Enter/Exit Programming Mode Symbologies CODE 11 The following options apply to the Code 11 symbology. Code 11 Enable/Disable When disabled, the reader will not read Code 11 bar codes. $CC1EN00(CR) DEFAULT Code 11 = Disable $CC1EN01(CR) Code 11 = Enable Code 11 Check Character Calculation This option enables/disables calculation and verification of optional Code 11 check character.
Symbologies Enter/Exit Programming Mode Code 11 Check Character Transmission This feature enables/disables transmission of an optional Code 11 check character. $CC1CT00(CR) Code 11 Check Character Transmission = Don’t Send $CC1CT01(CR) DEFAULT Code 11 Check Character Transmission = Send Code 11 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 11 symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set.
Enter/Exit Programming Mode Symbologies Code 11 Set Length 1 This feature specifies one of the bar code lengths for Code 11 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s check and data characters. The length can be set from 2 to 50 characters. Table 15 provides some examples for setting Length 1. See page 255 for detailed instructions on setting this feature. Table 15.
Symbologies Enter/Exit Programming Mode Code 11 Set Length 2 This feature specifies one of the bar code lengths for Code 11 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check and data characters. The length can be set from 2 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 16 provides examples for setting Length 2.
Enter/Exit Programming Mode Symbologies GS1 DATABAR™ OMNIDIRECTIONAL The following options apply to the GS1 DataBar™ Omnidirectional (formerly RSS-14) symbology. GS1 DataBar™ Omnidirectional Enable/Disable When disabled, the reader will not read GS1 DataBar™ Omnidirectional bar codes.
Symbologies Enter/Exit Programming Mode GS1 DataBar™ Omnidirectional 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label for this symbology is decoded.
Enter/Exit Programming Mode Symbologies GS1 DataBar™ Expanded GS1-128 Emulation When enabled, GS1 DataBar™ Expanded bar codes will be translated to the GS1-128 label data format. $CXBU800(CR) DEFAULT GS1 DataBar™ Expanded GS1-128 Emulation = Disable $CXBU801(CR) GS1 DataBar™ Expanded GS1-128 Emulation = Enable GS1 DataBar™ Expanded 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label of this symbology is decoded.
Symbologies Enter/Exit Programming Mode GS1 DataBar™ Expanded Length Control This feature specifies either variable length decoding or fixed length decoding for the GS1 DataBar™ Expanded symbology. Variable Length: For variable-length decoding, a minimum length may be set. Fixed Length: For fixed-length decoding, two different lengths may be set.
Enter/Exit Programming Mode Symbologies GS1 DataBar™ Expanded Set Length 1 This feature specifies one of the bar code lengths for GS1 DataBar™ Expanded Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only. The length can be set from 1 to 74 characters. Table 17 provides some examples for setting Length 1. See page 255 for detailed instructions on setting this feature.
Symbologies Enter/Exit Programming Mode GS1 DataBar™ Expanded Set Length 2 This feature specifies one of the bar code lengths for GS1 DataBar™ Expanded Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only. The length can be set from 1 to 74 characters. A setting of 0 specifies to ignore this length (only one fixed length). Table 18 provides examples for setting Length 2.
Enter/Exit Programming Mode Symbologies GS1 DATABAR™ LIMITED The following options apply to the GS1 DataBar™ Limited (formerly RSS Limited) symbology. GS1 DataBar™ Limited Enable/Disable When disabled, the reader will not read GS1 DataBar™ Limited bar codes. $CLBEN00(CR) DEFAULT GS1 DataBar™ Limited = Disable $CLBEN01(CR) GS1 DataBar™ Limited = Enable GS1 DataBar™ Limited GS1-128 Emulation When enabled, GS1 DataBar™ Limited bar codes will be translated to the GS1-128 label data format.
Symbologies Enter/Exit Programming Mode GS1 DataBar™ Limited 2D Component This feature enables/disables a requirement that a 2D label component be decoded when a base label of this symbology is decoded. $CLB2D00(CR) DEFAULT GS1 DataBar™ Limited 2D Component = Disable (2D component not required) $CLB2D01(CR) GS1 DataBar™ Limited 2D Component = 2D component must be decoded CODE 93 The following options apply to the Code 93 symbology.
Enter/Exit Programming Mode Symbologies Code 93 Check Character Calculation Enables/disables calculation and verification of an optional Code 93 check character.
Symbologies Enter/Exit Programming Mode Code 93 Length Control This feature specifies either variable length decoding or fixed length decoding for the Code 93 symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set.
Enter/Exit Programming Mode Symbologies Code 93 Set Length 1 Specifies one of the bar code lengths for Code 93 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only. The length can be set from 01 to 50 characters. Table 19 provides some examples for setting Length 1. See page 255 for detailed instructions on setting this feature. Table 19.
Symbologies Enter/Exit Programming Mode Code 93 Set Length 2 This feature specifies one of the bar code lengths for Code 93 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
Enter/Exit Programming Mode Symbologies Code 93 Quiet Zones Enables/disables quiet zones for Code 93. $CC9LO02(CR) Code 93 Quiet Zones = Quiet Zones on two sides $CC9LO03(CR) DEFAULT Code 93 Quiet Zones = Small Quiet Zones on two sides MSI The following options apply to the MSI symbology. MSI Enable/Disable Enables/Disables ability of reader to decode MSI labels.
Symbologies Enter/Exit Programming Mode MSI Check Character Calculation Enables/Disables calculation and verification of an optional MSI check character. $CMSCC00(CR) MSI Check Character Calculation = Disable $CMSCC01(CR) DEFAULT MSI Check Character Calculation = Enable Mod10 $CMSCC02(CR) MSI Check Character Calculation = Enable Mod11/10 $CMSCC03(CR) MSI Check Character Calculation = Enable Mod10/10 MSI Check Character Transmission Enables/disables transmission of an MSI check character.
Enter/Exit Programming Mode Symbologies MSI Length Control This feature specifies either variable length decoding or fixed length decoding for the MSI symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set.
Symbologies Enter/Exit Programming Mode MSI Set Length 1 This feature specifies one of the bar code lengths for MSI Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only. The length can be set from 01 to 50 characters. Table 21 provides some examples for setting Length 1. See page 255 for detailed instructions on setting this feature. Table 21.
Enter/Exit Programming Mode Symbologies MSI Set Length 2 This feature specifies one of the bar code lengths for MSI Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
Symbologies Enter/Exit Programming Mode PLESSEY The following options apply to the Plessey symbology. Plessey Enable/Disable Enables/Disables ability of reader to decode Plessey labels. $CPLEN00CR) DEFAULT Plessey = Disable $CPLEN01CR) Plessey = Enable Plessey Check Character Calculation Enables/Disables calculation and verification of an optional Plessey check character.
Enter/Exit Programming Mode Symbologies Plessey Check Character Transmission Enables/disables transmission of an MSI check character. $CPLCT00(CR) Plessey Check Character Transmission = Disable $CPLCT01(CR) DEFAULT Plessey Check Character Transmission = Enable Plessey Length Control This feature specifies either variable length decoding or fixed length decoding for the Plessey symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set.
Symbologies Enter/Exit Programming Mode Plessey Set Length 1 This feature specifies one of the bar code lengths for Plessey Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only. The length can be set from 01 to 50 characters. Table 23 provides some examples for setting Length 1. See page 255 for detailed instructions on setting this feature. Table 23.
Enter/Exit Programming Mode Symbologies Plessey Set Length 2 This feature specifies one of the bar code lengths for Plessey Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore this length (only one fixed length).
2D SYMBOLOGIES • • 2D Global Features 2D Maximum Decoding Time on page • 2D Normal/Inverse Symbol Control on 186 page 187 2D Structured Append on page 187 2D Symbologies The reader supports the following 2D symbologies (bar code types). Symbology-dependent options for each symbology are included in this chapter. See "1D Code Selection" starting on page 93 for configuration of 1D bar codes.
Enter/Exit Programming Mode 2D Symbologies 2D Maximum Decoding Time This feature specifies the maximum amount of time the software will spend attempting to decode a 2D label. The selectable range is 10 milliseconds to 2.55 milliseconds.
2D Symbologies Enter/Exit Programming Mode 2D Structured Append Enables/disables ability of reader to append multiple 2D Codes labels in a structured format.
Enter/Exit Programming Mode 2D Symbologies Aztec Code Aztec Code Enable / Disable Enables/disables the ability of the reader to decode Aztec Code labels. $CAZEN00(CR) Aztec Code = Disable $CAZEN01(CR) DEFAULT Aztec Code = Enable Aztec Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set.
2D Symbologies Enter/Exit Programming Mode Aztec Code Set Length 1 Specifies one of the bar code lengths for Aztec Code Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Characters can be set from 0001 to 3,832 characters in increments of 0001 (pad with zeroes). See page 255 for detailed instructions on setting this feature.
Enter/Exit Programming Mode 2D Symbologies Aztec Code Set Length 2 This feature specifies one of the bar code lengths for Aztec Code Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 3,832 characters in increments of 0001 (pad with zeroes). See page 255 for detailed instructions on setting this feature.
2D Symbologies Enter/Exit Programming Mode China Sensible Code China Sensible Code Enable / Disable Enables/disables the ability of the reader to decode China Sensible Code labels. $CCSEN00(CR) DEFAULT China Sensible Code = Disable $CCSEN01(CR) China Sensible Code = Enable China Sensible Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set.
Enter/Exit Programming Mode 2D Symbologies China Sensible Code Set Length 1 Specifies one of the bar code lengths for China Sensible Code Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Characters can be set from 0001 to 7,827 characters in increments of 0001 (pad with zeroes). See page 255 for detailed instructions on setting this feature.
2D Symbologies Enter/Exit Programming Mode China Sensible Code Set Length 2 This feature specifies one of the bar code lengths for China Sensible Code Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 7,827 characters in increments of 0001 (pad with zeroes). See page 255 for detailed instructions on setting this feature.
Enter/Exit Programming Mode 2D Symbologies Data Matrix Data Matrix Enable / Disable Enables/disables ability of reader to decode Data Matrix labels. $CDMEN00(CR) Data Matrix = Disable $CDMEN01(CR) DEFAULT Data Matrix = Enable Data Matrix Square/Rectangular Style Specifies the options available when reading Data Matrix with different form factors.
2D Symbologies Enter/Exit Programming Mode Data Matrix Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set.
Enter/Exit Programming Mode 2D Symbologies Data Matrix Set Length 2 This feature specifies one of the bar code lengths for Data Matrix Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 3,116 characters in increments of 0001 (pad with zeroes). See page 255 for detailed instructions on setting this feature.
2D Symbologies Enter/Exit Programming Mode Maxicode Maxicode Enable / Disable Enables/disables ability of reader to decode Maxicode labels. $CMXEN00(CR) DEFAULT Maxicode = Disable $CMXEN01(CR) Maxicode = Enable Maxicode Primary Message Transmission Enables/disables the transmission of only the Primary Message when the Secondary Message is not readable.
Enter/Exit Programming Mode 2D Symbologies Maxicode Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set.
2D Symbologies Enter/Exit Programming Mode Maxicode Set Length 2 This feature specifies one of the bar code lengths for Maxicode Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 0145 characters in increments of 0001 (pad with zeroes). See page 255 for detailed instructions on setting this feature.
Enter/Exit Programming Mode 2D Symbologies PDF417 PDF417 Enable / Disable Enables/disables the ability of the reader to decode PDF417 labels. $CP4EN00(CR) PDF417 = Disable $CP4EN01(CR) DEFAULT PDF417 = Enable PDF417 Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set.
2D Symbologies Enter/Exit Programming Mode PDF417 Set Length 1 Specifies one of the bar code lengths for PDF417 Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Length includes the bar code’s data characters only. Characters can be set from 0001 to 2,710 characters (pad with zeroes) in increments of 01. Any value greater than 2,710 will be considered to be 2,710.
Enter/Exit Programming Mode 2D Symbologies PDF417 Set Length 2 This feature specifies one of the bar code lengths for PDF417 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Length includes the bar code’s check, data, and full-ASCII shift characters. The length does not include start/stop characters. Characters can be set from 01 to 2,710 characters (pad with zeroes) in increments of 01.
2D Symbologies Enter/Exit Programming Mode Micro PDF417 Micro PDF417 Enable / Disable Enables/disables the ability of the reader to decode Micro PDF417 labels. $CMIEN00(CR) DEFAULT Micro PDF417 = Disable $CMIEN01(CR) Micro PDF417 = Enable Micro PDF417 Code 128 GS1-128 Emulation Specifies which AIM ID to use for MicroPDF labels when doing Code 128 or GS1-128 emulation.
Enter/Exit Programming Mode 2D Symbologies Micro PDF417 Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set.
2D Symbologies Enter/Exit Programming Mode Micro PDF417 Set Length 2 This feature specifies one of the bar code lengths for Micro PDF417 Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length includes the bar code’s data characters only. Characters can be set from 0001 to 0366 characters (pad with zeroes) in increments of 01. Any value greater than 0366 will be considered to be 0366.
Enter/Exit Programming Mode 2D Symbologies QR Code QR Code Enable / Disable Enables/disables the ability of the reader to decode QR Code labels. $CQREN00(CR) QR Code = Disable $CQREN01(CR) DEFAULT QR Code = Enable QR Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set.
2D Symbologies Enter/Exit Programming Mode QR Code Set Length 1 Specifies one of the bar code lengths for QR Code Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Characters can be set from 0001 to 7,089 characters in increments of 0001 (pad with zeroes). See page 255 for detailed instructions on setting this feature.
Enter/Exit Programming Mode 2D Symbologies QR Code Set Length 2 This feature specifies one of the bar code lengths for QR Code Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 7,089 characters in increments of 0001 (pad with zeroes). See page 255 for detailed instructions on setting this feature.
2D Symbologies Enter/Exit Programming Mode Micro QR Code Micro QR Code Enable/Disable Enables/disables the ability of the reader to decode Micro QR Code labels. MQEN00 DEFAULT Micro QR Code = Disable MQEN01 Micro QR Code = Enable Micro QR Code Length Control This feature specifies either variable length decoding or fixed length decoding for this symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set.
Enter/Exit Programming Mode 2D Symbologies Micro QR Code Set Length 1 Specifies one of the bar code lengths for Micro QR Code Length Control. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed length if in Fixed Length Mode. Characters can be set from 0001 to 0035 characters in increments of 0001 (pad with zeroes). See page 255 for detailed instructions on setting this feature.
2D Symbologies Enter/Exit Programming Mode Micro QR Code Set Length 2 This feature specifies one of the bar code lengths for Micro QR Code Length Control. Length 2 is the maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length Mode. Characters can be set from 0001 to 0035 characters in increments of 0001 (pad with zeroes). See page 255 for detailed instructions on setting this feature.
Enter/Exit Programming Mode 2D Symbologies UCC Composite UCC Composite Enable / Disable Enables/disables the ability of the reader to decode the stacked part of a UCC Composite label. This feature is not effective when Global AIM IDs are enabled (see "Global AIM ID" on page 53).
2D Symbologies Enter/Exit Programming Mode UCC Optional Composite Timer Specifies the amount of time the system will wait for the stacked part of a UCC Composite label before transmitting the linear label without an add-on.
Enter/Exit Programming Mode 2D Symbologies Postal Code Selection Enables/disables the ability of the scanner to decode labels of a specific postal symbology.
2D Symbologies Enter/Exit Programming Mode Postal Code Selection — cont. $CPOEN06(CR) Postal Code Selection = Enable Japan Post $CPOEN07(CR) Postal Code Selection = Enable IMB $CPOEN08(CR) Postal Code Selection = Enable Sweden Post $CPOEN09(CR) Postal Code Selection = Enable Portugal Post Postnet BB Control Controls the ability of the scanner to decode B and B' fields of Postnet labels.
2D Symbologies NOTES 216 Gryphon™ I GFS4400
Chapter 4 Software Configuration Strings RS-232 models (as well as USB models with the USB-COM Interface selected) can be configured using the serial strings contained in this chapter. To configure RS-232 models by using the configuration strings: 1. Connect your reader to a PC RS-232 port according to the information in Attaching Reader to Host, starting on page 14. Set the PC serial port to the default RS-232 communication parameters (see , starting on page 291).
Software Configuration Strings Command Syntax 1. Enter Service (Serial String Programming) Mode $S This command automatically sets the reader communication to 115200 baud rate. Before continuing, please set the baud rate of the Terminal Emulation Program to 115200. 2.
Software Configuration Strings Example 1: 1. $S Enter Service Mode. 2. $CLFCA02 Write command "Convert to Lower Case" to current configuration. 3. $Ar Apply and Save Configuration to FLASH (permanent memory) and Exit Service Mode. Each configuration parameter setting removes the condition previously active for that parameter. Example 2: 1. $S Enter Service Mode. 2. $HA05 Select RS232 Interface. 3. $Ar Apply and Save Configuration to FLASH (permanent memory) and Exit Service Mode.
Software Configuration Strings SERIAL CONFIGURATION STRINGS ENTER/EXIT CONFIGURATION COMMANDS Description Command Enter Service Mode (configuration) fixed 115200 Baud rate S Exit Service Mode (configuration) return to programmed Baud rate s Apply Configuration to RAM (temporary memory) and Exit Service Mode r01 Apply and Save Configuration to FLASH (permanent memory) and Exit Service Mode Ar To configure the reader using configuration strings, it must be placed into Service Mode, which automatica
Software Configuration Strings INTERFACE SELECTION COMMANDS Description Command Restore Current Interface (Custom) Default Configuration HA00 RS232-STD HA05 USB-COM HA47 RS232-Wincor-Nixdorf HA12 USB-KBD HA35 USB-KBD-ALT HA2B USB KBD-APPLE HA2C To read a particular parameter setting from the reader, send the read parameter command without any value. The reader will respond with its currently configured value.
Software Configuration Strings RS-232/USB-COM PARAMETERS Description Parameter Value Intercharacter Delay No delay or from 10 to 990 ms R2IC a Disable Character Host command character which disables the reader R2DC b Enable Character Host command character which enables the reader R2EC b ACK/NAK Options Disable R2AE 00 Enable for label transmission 01 Enable for host command acknowledge 02 Enable for label transmission and host command acknowledge 03 ACK Character Selects character
Software Configuration Strings USB-KBD / USB-KBD-ALT / USB-KBD-APPLE PARAMETERS Description Keyboard Country Mode Send Control Characters USB Keyboard Speed *US Parameter Value KBCO 00 *Belgium 01 *Britain 02 Croatia 11 Czechoslovakia 0E Denmark 03 *France 04 *Germany 05 Hungary 0D *Italy 06 Japanese (106 key) 0C Norway 07 Poland 12 Portugal 08 Romania 10 Slovakia 0F *Spain 09 *Sweden 0A Switzerland 0B CTRL + KEY KBSC 00 CTRL + SHIFT + KEY 01 Special Function
Software Configuration Strings READING PARAMETERS Description Double Read Timeout 20 to 2,550 milliseconds (2.55 seconds) in 10ms increments Illumination Mode Disabled Operating Modes Phase Off Event Parameter Value SNDR f SPIL 00 Triggered 01 Enabled 02 On Line SNRM 00 Serial On Line 01 Automatic 02 Automatic (Object Sense) 03 Trigger Stop SPTO 00 Timeout 01 Trigger Stop-Timeout 02 Timeout (Scan Active Time) 1 to 255 seconds in 1 second intervals.
Software Configuration Strings DATA FORMAT Description Data Transmission On Decode Parameter Value LFTX 01 After Phase Off Code Verifier Mode Disabled 00 LFCV 00 Transmit Wrong String 01 Transmit Wrong Code 02 Match String Any string of characters (max 20) between 00-FE COVS k Wrong Code String Any string of characters (max 20) between 00-FE WCVS k Case Conversion Disable LFCA 00 Upper Case 01 Lower Case 02 Global Prefix (Header) Any string of characters (max 20) between 00-F
Software Configuration Strings Custom Code Identifiers Any string of characters (max 3) between 00-FE UPC-A ABID k UPC-E EBID k EAN-8 8BID k EAN-13 3BID k UPC-A/P2 A2ID k UPC-A/P5 A5ID k UPC-E/P2 E2ID k UPC-E/P5 E5ID k EAN-8/P2 82ID k EAN-8/P5 85ID k EAN-13/P2 32ID k EAN-13/P5 35ID k ISBN ISID k ISSN INID k GTIN for EAN/UPC w/o Add-On GBID k GTIN for EAN/UPC w P2 G2ID k GTIN for EAN/UPC w P5 G5ID k Code 39 C3ID k Code 32 P3ID k Code 128 C8ID k G
Software Configuration Strings Custom Code Identifiers Any string of characters (max 3) between 00-FE Code 93 C9ID k MSI MSID k Plessey PLID k Parameter Value OUA1 00 k = Hex value from 00 to FE representing the ASCII character DIGITAL OUTPUT Description OUTPUT Activation Event Deactivation Event Disable Good Read 01 No Read 02 Wrong Code 03 Disable OUD1 00 Timeout 01 Reading Phase Active 02 Deactivation Timeout 100 to 25500 ms OUT1 n Active Level Closed OUL1 00 Open
Software Configuration Strings LED AND BEEPER INDICATORS Description Power On Alert Disable Parameter Value BPPU 00 Enable Indicate Good Read On Decode 01 BPIN After Transmit Good Read Beep Disable 00 01 BPVO Enable 00 01 Good Read Beep Length Time length from 10 to 2550 ms BPLE o Good Read Led Duration Time length from 0 to 25,500 ms LAGL f Green Spot Duration Disable LSSP 00 Led Indication Short 300ms 01 Medium 500ms 02 Long 800ms 03 On Decode BPIN After Transmit 00 0
Software Configuration Strings CODE SELECTION Description Parameter Value ABEN 00 UPC-A UPC-A Disable 01 Enable Check Character Tx Disable ABCT 01 Enable Expand to EAN-13 Disable AB3B Disable ABNS Coupon Control One Read 00 01 Enable Minimum Reads 00 01 Enable Number System Tx 00 ABMR 01 Two Reads 02 Three Reads 03 Four Reads 04 Allow all coupon barcodes to be decoded CPCL 00 Enable only UPC-A coupon decoding 01 Enable only GS1 Databar coupon decoding 02 UPC-E UPC-E
Software Configuration Strings CODE SELECTION Description Parameter Value 01 3BIN 00 Enable ISSN Conversion Disable 01 Enable Flag 1 Character Disable 3BF1 01 Enable Minimum Reads Coupon Control One Read 00 3BMR 01 Two Reads 02 Three Reads 03 Four Reads 04 Allow all coupon barcodes to be decoded CPCL 00 Enable only UPC-A coupon decoding 01 Enable only GS1 Databar coupon decoding 02 EAN-8 EAN-8 Disable 8BEN 01 Enable Check Character Tx Disable 8BCT Disable 8B3B One Rea
Software Configuration Strings CODE SELECTION Description Parameter Value GBEN 00 EAN/UPC Global Settings GTIN Format Disable 01 Enable Decoding Level Character Correlation UNDL Disable Level 1 01 Level 2 02 Level 3 03 Level 4 04 Level 5 05 UNCO Disable 00 01 Enable In-Store Minimum Reads 00 INMR One Read 01 Two Reads 02 Three Reads 03 Four Reads 04 Code 39 Code 39 C3EN Disable 01 Enable Code 39 Full ASCII C3FA Disable C3LC Variable Code 32 (Italian Pharma) Length
Software Configuration Strings CODE SELECTION Description Code 39 Check Tx Parameter C3CT Disable 01 Enable Code 39 Start/Stop Tx Value 00 C3SS Disable 00 01 Enable Decoding Options Minimum Reads Decoding Level One Read C3MR 01 Two Reads 02 Three Reads 03 Four Reads 04 Disable C3DL 00 Level 1 01 Level 2 02 Level 3 03 Level 4 04 Level 5 05 Interdigit Ratio Any ratio or 1 to 10 C3IR r Character Correlation Disable C3CO 00 01 Enable Quiet Zones Stitching Quiet Zone on
Software Configuration Strings CODE SELECTION Description Expand to Code 39 Parameter C8C3 Disable Value 00 01 Enable Check Options Check Tx C8CT Disable 01 Enable Function Character Tx C8TF Disable 00 01 Enable Sub-Code Change Tx 00 C8SC Disable 00 01 Enable Decoding Options Minimum Reads Decoding Level Character Correlation One Read C8MR Two Reads 02 Three Reads 03 Four Reads 04 Disable C8DL Stitching 00 Level 1 01 Level 2 02 Level 3 03 Level 4 04 Level 5 05 Disab
Software Configuration Strings CODE SELECTION Description Parameter Value I2EN 00 Interleaved 2 of 5 (I 2 of 5) I 2 of 5 Disable 01 Enable Code Length Control Variable I2LC 01 Fixed Set Length Length 1 (or Min Length) from 2 to 50 characters (only even numbers) Length 2 (or Max Length) from 0 or from 2 to 50 characters (only even numbers) Check Options Check Calculation Check Tx Disable 00 I2L1 v I2L2 v I2CC 00 Enable Standard(Mod 10) 01 Enable German Parcel 02 Enable DHL 04 En
Software Configuration Strings CODE SELECTION Description Parameter Value S2EN 00 Standard 2 of 5 Standard 2 of 5 Disable 01 Enable Code Length Control S2LC Variable 01 Fixed Set Length Check Calculation Length 1 (or Min Length) from 1 to 50 characters S2L1 v Length 2 (or Max Length) 0 or from 1 to 50 characters Check Options S2L2 v Disable S2CC 00 01 Enable Check Tx 00 S2CT Disable 00 01 Enable Decoding Options Minimum Reads Decoding Level Character Correlation One Read S2MR
Software Configuration Strings CODE SELECTION Description Check Tx Parameter U2CT Disable Value 00 01 Enable Decoding Options Minimum Reads Character Correlation U2MR One Read Two Reads 02 Three Reads 03 Four Reads 04 U2CO Disable 00 01 Enable Stitching 01 U2ST Disable 00 01 Enable IATA IATA IAEN Disable 01 Enable Check Tx 00 IACT Disable 00 01 Enable Datalogic 2 of 5 Datalogic 2 of 5 D2EN Disable 01 Enable Code Length Control D2LC Variable Check Calculation Length 1 (or
Software Configuration Strings CODE SELECTION Description Character Correlation Parameter Level 4 Value 04 Level 5 05 D2CO Disable 01 Enable Stitching 00 D2ST Disable 00 01 Enable Codabar Codabar CBEN Disable 01 Enable Code Length Control CBLC Variable 00 01 Fixed Set Length 00 Length 1 (or Min Length) from 3 to 50 characters CBL1 v Length 2 (or Max Length) 0 or from 3 to 50 characters CBL2 v Disable CBAB 00 ABC Codabar ABC Codabar 01 Enable Concatenation Mode CBCM Static
Software Configuration Strings CODE SELECTION Description Decoding Level Character Correlation Parameter Three Reads Value 03 Four Reads 04 Disable CBDL 00 Level 1 01 Level 2 02 Level 3 03 Level 4 04 Level 5 05 Disable CBCO 00 01 Enable Interdigit Ratio Any ratio or 1 to 10 CBIR r Quiet Zones Quiet Zone on One Side CBLO 01 Stitching Quiet Zones on Two Sides 02 Auto 03 Virtual Quiet Zones on Two Sides 04 Small Quiet Zones on Two Sides 05 Disable CBST 00 01 Enable GS
Software Configuration Strings CODE SELECTION Description Set Length Minimum Reads Coupon Control Parameter XBL1 Value w Length 2 (or Max Length) 0 or from 1 to 74 characters Expanded Decoding Options XBL2 w One Read XBMR 01 Length 1 (or Min Length) from 1 to 74 characters Two Reads 02 Three Reads 03 Four Reads 04 Allow all coupon barcodes to be decoded CPCL 00 Enable only UPC-A coupon decoding 01 Enable only GS1 Databar coupon decoding 02 GS1 Databar Limited GS1 Databar Limited LB
Software Configuration Strings CODE SELECTION Description Decoding Level Character Correlation Parameter Two Reads Value 02 Three Reads 03 Four Reads 04 C9DL Disable Level 1 01 Level 2 02 Level 3 03 Level 4 04 Level 5 05 C9CO Disable Stitching 00 01 Enable Quiet Zones 00 C9LO No Quiet Zones 00 Quiet Zone on One Side 01 Quiet Zones on Two Sides 02 Auto 03 Virtual Quiet Zones on Two Sides 04 C9ST Disable 00 01 Enable MSI MSI MSEN Disable 01 Enable Code Length Control
Software Configuration Strings CODE SELECTION Description Decoding Level Stitching Parameter MSDL Disable Value 00 Level 1 01 Level 2 02 Level 3 03 Level 4 04 Level 5 05 MSST Disable 00 01 Enable Plessey Plessey PLEN Disable 01 Enable Code Length Control PLLC Variable Check Calculation Check Tx 00 01 Fixed Set Length 00 Length 1 (or Min Length) from 1 to 50 characters PLL1 v Length 2 (or Max Length) 0 or from 1 to 50 characters Check Options PLL2 v Disable PLCC 00 Stand
Software Configuration Strings 2D Codes 2D GLOBAL FEATURES Description Parameter Value 2D Max Decoding Time 10-2550 ms in 10ms intervals DETM h 2D Structured Append Disabled DESA 00 Enabled 01 2D Normal/Inverse Symbol Normal Control IPNR 00 Inverse 01 Both Normal & Inverse 02 2D CODE SELECTION Aztec Code Aztec Code Disabled AZEN Enabled Code Length Control Variable 01 AZLC Fixed Set Length 00 00 01 Length1 (Min for Variable) 1 AZL1 q Length2 (Max for Variable) 3832 AZL2 q
Software Configuration Strings Set Length Length1 (Min for Variable) 1 DML1 t Length2 (Max for Variable) 3116 DML2 t Disabled MXEN 00 Maxicode Maxicode Enabled Primary Message TX Disabled 01 MXPT Enabled Code Length Control Variable 01 MXLC Fixed Set Length 00 00 01 Length1 (Min for Variable) 1 MXL1 u Length2 (Max for Variable) 145 MXL2 u Disabled P4EN 00 PDF417 PDF417 Enabled Code Length Control Variable 01 P4LC Fixed Set Length 00 01 Length1 (Min for Variable) 1 P4L1 v
Software Configuration Strings Set Length Length1 (Min for Variable) 1 QRL1 x Length2 (Max for Variable) 7089 QRL2 x Disabled MQEN 00 Micro QR Code Micro QR Code Enabled Code Length Control Variable 01 MQLC Fixed Set Length 00 01 Length1 (Min for Variable) 1 MQL1 y Length2 (Max for Variable) 35 MQL2 y Disabled CMEN 00 UCC Composite UCC Composite Enabled Optional Composite Timer Variable: 00 = disabled, 100-3000 ms in 100ms intervals 01 CMOT i POEN 00 POBB 00 Postal Codes Po
Chapter 5 References This section contains explanations and examples of selected bar code features. See Configuration Using Bar Codes, starting on page 21 for the actual bar code labels used to configure the reader. RS-232 Parameters............................................................................................................... RS-232 Only........................................................................................................... RS-232/USB COM Parameters......................
References RS-232 Parameters RS-232 Parameters RS-232 Only Baud Rate Baud rate is the number of bits of data transmitted per second. Set the reader's baud rate to match the baud rate setting of the host device. With an improper baud rate setting, data may not reach the host correctly. Stop Bits The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream.
RS-232 Parameters References RS-232/USB COM Parameters Intercharacter Delay This parameter specifies the intercharacter delay between the end of one character and the beginning of the next. The delay can be set within a range of zero (0) to 990 milliseconds in 10ms increments. A setting of zero specifies no delay. To set the delay: 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 10 (setting is in 10ms increments). Pad the result with leading zeroes to yield two digits.
References RS-232 Parameters ACK NAK Options This enables/disables the ability of the reader to support the RS-232 ACK/NAK protocol. When configured, the reader and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error. Options are: • Disable • Enable for label transmission — The reader expects an ACK/NAK response from the host when a label is sent. • Enable for host-command acknowledge — The reader will respond with ACK/NAK when the host sends a command.
RS-232 Parameters References NAK Character This setting specifies an ASCII character or hex value to be used as the NAK character. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8bit data is not recognized when the option Data Bits has been set as 7 Data Bits. To set this feature: 1. Determine the desired character or value. 2.
References RS-232 Parameters ACK NAK Timeout Value This option specifies the amount of time the reader waits for an ACK character from the host following label transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A selection of 0 disables the timeout. To set this value: 1. Determine the desired setting in milliseconds. 2. Divide the desired setting by 200 (setting is in 200ms increments). Pad the result with leading zeroes to yield two digits.
RS-232 Parameters References ACK NAK Retry Count This feature specifies the number of times the reader retries a label transmission due to a retry condition. The selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies unlimited retries. To set this feature: 1. Determine the desired setting. 2. Pad the number with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 3.
References RS-232 Parameters Disable Character Specifies the value of the RS-232 host command used to disable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8bit data is not recognized when the option Data Bits has been set as 7 Data Bits. To set the value: 1. Determine the desired character or value.
RS-232 Parameters References Enable Character Specifies the value of the RS-232 host command used to enable the reader. ASCII characters or any hex value from 0 to 0xFF can be selected. Setting to previously defined characters such as XON, XOFF, or host commands conflicts with normal operation of these characters. 8bit data is not recognized when the option Data Bits has been set as 7 Data Bits. To set this feature: Determine the desired character or value.
References RS-232 Parameters USB Intercode Delay Specifies the delay between labels transmitted to the host for this interface. The selectable range for this feature is from 0 to 99 seconds. Follow these instructions to set this feature: 1. Determine the desired setting. 2. Pad the number with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05, 20 = 20, etc 3. Go to page 43 and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Programming Mode. 4.
Symbologies References Symbologies Set Length Length Control allows you to select either variable length decoding or fixed length decoding for the specified symbology. Variable Length: For variable length decoding, a minimum and maximum length may be set. Fixed Length: For fixed length decoding, two different lengths may be set. Set Length 1 This feature specifies one of the bar code lengths for Length Control.
References Data Editing 3. Scan the bar code to SELECT LENGTH 2 SETTING for your selected symbology. 4. Scan the appropriate two digits from the keypad in Appendix E, Keypad that represent the length setting which was determined in the steps above. You will hear a two-beep indication after the last character. If you make a mistake, before the last character scan the CANCEL bar code to abort and not save the entry string. You can then start again at the beginning. 5.
Data Editing References • • • A prefix or suffix may be applied only to a specified symbology (reference 1D Code Selection, starting on page 93) or across all symbologies (set via the Global features in this chapter). You can add any character from the ASCII Chart (from 00-FF) on the inside back cover of this manual as a prefix, suffix or Label ID. Enter prefixes and suffixes in the order in which you want them to appear on the output.
References Data Editing Global AIM ID This feature enables/disables addition of AIM IDs for all symbology types. AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned bar code data. AIM label identifiers consist of three characters as follows: • A close brace character (ASCII ‘]’), followed by... • A code character (see the table below), followed by... • A modifier character (the modifier character is symbol dependent).
Data Editing References Label ID A Label ID is a customizable code of up to three ASCII characters (each can be one of hex 0x010xFF), used to identify a bar code (symbology) type. It can be appended previous to or following the transmitted bar code data depending upon how this option is enabled.
References Data Editing USA Label ID set Symbology EU Label ID set Default Character Default ASCII Default Character Default ASCII DATABAR 14 COMPOSITE R4 523400 c 523400 DATABAR EXPANDED RX 525800 t 740000 DATABAR EXPANDED COMPOSITE RX 525800 d 525800 DATABAR LIMITED RL 524C00 v 760000 DATABAR LIMITED COMPOSITE RL 524C00 i 524C00 DATA MATRIX Dm 446D00 w 770000 EAN128 000000 k 6B0000 EAN128 COMPOSITE 000000 $E 244500 EAN13 F 460000 B 420000 EAN13 P2 F 4600
Data Editing References USA Label ID set Symbology EU Label ID set Default Character Default ASCII Default Character Default ASCII MSI @ 400000 Z 5A0000 PDF417 P 500000 r 720000 PLESSEY a 610000 a 610000 POSTAL AUSTRALIAN $K 244B00 $K 244B00 POSTAL IMB $V 245600 $V 245600 POSTAL JAPANESE $R 245200 $R 245200 POSTAL KIX $U 245500 $U 245500 POSTAL PLANET $W 245700 $W 245700 POSTAL PORTUGAL $P 245000 $P 245000 POSTAL POSTNET BB $L 244C00 $L 244C00 POSTAL
References Data Editing Label ID: Set Individually Per Symbology To configure a Label ID individually for a single symbology: 1. Go to page 57 and scan the ENTER/EXIT bar code. 2. Select Label ID position as either BEFORE (Enable as Prefix) or AFTER (Enable as suffix) by scanning the appropriate bar code in the section "Label ID Control" on page 57. Reference Figure 6 for Label ID positioning options if multiple identification features are enabled. 3.
Data Editing References Table 34. Label ID Examples STEP ACTION EXAMPLES 1. Scan the ENTER/EXIT bar code (Scanner enters Programming Mode) 2. Determine placement of the Label ID characters BEFORE or AFTER with regard to scanned Enable as Prefix data using Label ID Enable as Suffix Enable as Prefix Enable as Suffix Code 39 Interleaved 2 of 5 Code 32 Control, starting on page 57 3.
References Data Editing Character Conversion Character conversion is an eight byte configuration item. The eight bytes are 4 character pairs represented in hexadecimal ASCII values. The first character in the pair is the character that will be converted. The second character in the pair is the character to convert to. If the character to convert in a pair is FF, then no conversion is done.
Data Editing References Scanner Data Formatting Control No Read String This feature allows the transmission of a programmable character or string when no code has been decoded (No read) during a reading phase (On Line Mode only). To set this feature: 1. Determine the desired character string (maximum 20). 2. Reference the ASCII Chart on the inside back cover of this manual to find the hex value assigned to the desired character. 3.
References Data Editing No wild card characters are supported. To set this feature: 1. Determine the desired character string (max 32). 2. Reference the ASCII Chart on the inside back cover of this manual to find the hex value assigned to the desired character. 3. Go to "Match String" on page 65 and scan ENTER/EXIT PROGRAMMING MODE to enter Programming Mode. 4. Scan the barcode: SELECT MATCH STRING. 5.
Digital Output References Digital Output Output Activation: Digital Output can set to be Activated/Deactivated when specified events occur. Line State: Selects whether the line is Active Low or Active High. Activation Event: Selects the event the line is activated on. Selectable events: Disabled, Good Read, No Read, Right Code, Wrong Code. Right Code and Wrong Code are available only if Code Verifier functionality is enabled. Deactivation Event: Selects the event the line is deactivated on.
References Reading Parameters Reading Parameters Double Read Timeout Double Read Timeout prevents a double read of the same label by setting the minimum time allowed between reads of labels of the same symbology and data. If the unit reads a label and sees the same label again within the specified timeout, the second read is ignored. Double Read Timeout does not apply to scan modes that require a trigger pull for each label read. Follow these instructions to set this feature: 1.
Reading Parameters References Good Read LED Duration This feature specifies the amount of time that the Good Read LED remains on following a good read. The good read LED on time can be set within a range of 10 milliseconds to 2,550 milliseconds (0.001 to 2.55 seconds) in 100ms increments. Follow these instructions to set this feature: 1. Determine the desired setting in milliseconds. A setting of 0 means that the good read LED stays on until the next time the trigger is pulled. 2.
References Scanning Features Scanning Features Operating Mode The following Operating Modes (Reading Modes) are supported: On Line In On Line mode, the reading phase is defined as the time between the Phase ON and Phase OFF events. The Phase events can be generated by an external input (trigger) or by the Trigger button. While in this mode the scanner activates reading only during a reading phase.
Scanning Features References Phase Off Event: Specifies whether the reading phase is closed on a timeout or phase off event. The following selections are available: • Trigger Stop: the reading phase ends when the serial stop character (or string) is received. Timeout is disabled. • Timeout: the reading phase ends when the timeout is expired. Serial stop character (or string) is ignored. • Trigger Stop - Timeout: the reading phase ends when the first event occured.
References Scanning Features Scanning Active Time This setting specifies the amount of time that the reader stays in scan ON state once the state is entered. It controls the Timeout within On Line & Serial On Line read modes Phase Off Event. The range for this setting is from 1 to 255 seconds in 1-second increments. Follow these instructions to set this feature: 1. Determine the desired setting. 2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 3.
Scanning Features References Aiming Duration Time Specifies the frame of time the aiming pointer remains on after decoding a label, when in On Line or Serial On Line mode. The range for this setting is from 1 to 255 seconds in 1-second increments. Follow these instructions to set this feature: 1. Determine the desired setting. 2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 = 005, 20 = 020, etc. 3.
References Scanning Features Multiple Labels Ordering by Code Symbology This feature Specifies the transmission ordering by symbology type, when Multiple Labels per Frame is enabled.Up to six symbologies can be selected. Zeroes must be added to pad the string to 12 characters if not using all six symbologies. The labels are ordered first as specified in the output mask.
Scanning Features References Table 40.
References Scanning Features NOTES 276 Gryphon™ I GFS4400
Appendix A Technical Specifications Table 41 contains Physical and Performance Characteristics, User Environment and Regulatory information. Table 41. Technical Specifications Item Description Physical Characteristics Color Grey Dimensions Height 1.54" / 39mm Length 2.24" / 57mm Width 2.28" / 58 mm Weight (with cable, without bracket) USB version - Approximately 6.3 ounces/170 g RS-232 version - Approximately 7.
Technical Specifications Item Description Current & Power Consumption Input current at 5V in Automatic (Object Sense) Reading Mode Operating (typical) 180 mA Operating (max) 250 mA Idle/standby (typical) 65 mA (On Line & Serial On Line Modes) 115 mA (Automatic Object Sense Mode) No idle in Automatic Mode Performance Characteristics Nominal Frame Rate 53 frames/second Light Source Dual Red LEDs Roll (Tilt) Tolerance Up to ± 180° Pitch Tolerance ± 70° * Skew (Yaw) Tolerance ± 80° * Print Con
Technical Specifications DataMatrix 10mil DataMatrix 15mil 2.7 1.2 17.1 24.6 1.1 0.5 6.7 9.7 QR Code 10mil QR Code 15mil 3.5 0.5 16.0 24.3 1.4 0.2 6.3 9.
Technical Specifications NOTE: The Scanner can also decode mirrored images of 2D matrix codes Datamatrix, QR Code and Maxicode. GFS4450-9 version: RS-232 Standard GFS4470 version:USB-COM, USB-Keyboard, USB-OEM Interfaces Supported User Environment Operating Temperature -4° to 122° F (-20° to 50° C) Storage Temperature -4° to 158° F (-20° to 70° C) Humidity Operating: 5% to 90% relative humidity, non condensing Drop specifications 5 drops from 30 inches (0.76 mt.
Technical Specifications Figure 7. Output Connection Output Connection Vext 14Vdc max GFS4450-9 USER INTERFACE c 9 OUT 5 GND DB9 Figure 8. Using GFS4450-9 Power Input Trigger Using GFS4450-9 Power GFS4450-9 EXT TRIGGER 6 VCC 1 TRIGGER 5 GND DB9 Figure 9.
Technical Specifications Imager Labeling The sample labels shown below are for illustrative purposes only. Please view the labels on your product for actual details, as they may vary. . LASER LIGHT - DO NOT STARE INTO BEAM. CLASS 2 LASER PRODUCT. OUTPUT RADIATION 1 mW AVG. EMITTED WAVE LENGTH 650nm IEC60825 - 1:2007 CAUTION - CLASS 2 LASER LIGHT WHEN OPEN. AVOID EXPOSURE 239045 Scanner Labels Aiming System The Gryphon™ aiming system meets the Class 2 requirements for laser safety.
Technical Specifications LED and Beeper Indications Button and LED Status The top of the product has a button and three indicator LEDs: ON = Power ON POWER (yellow LED) OFF = Power OFF or standby (only USB version) ON = Good Read GOOD (green LED) Blinks = USB enumeration or interface inactive or waiting for change of configuration ON = External trigger or button pressed or phase active TRIGGER (blue LED) Button Blinks = During transfer of captured image, during Flash memory updates, or as Presenta
Technical Specifications Indicator Description LED Beeper Limited Scanning Label Read Indicates that a host connection is not established. N/A Reader 'chirps' six times at the highest frequency and current volume. Reader Active Mode The reader is active and ready to scan. The LED is lit steadilya N/A Reader Disabled The reader has been disabled by the host.
Technical Specifications Programming Mode - The following indications ONLY occur when the reader is in Programming Mode. Indicator Description Label Programming Mode Entry A valid programming label has been scanned. Label Programming Mode Rejection of Label A label has been rejected. Label Programming Mode Acceptance of Partial Label In cases where multiple labels must be scanned to program one feature, this indication acknowledges each portion as it is successfully scanned.
Technical Specifications NOTES 286 Gryphon™ I GFS4400
Appendix B Aimer Calibration The Scan Modules in the GFS4400 series contain a laser-based aiming system consisting of four corner dots and a center crosshair pattern that helps define the reading volume. The center cross location in the imager's Field Of View (FOV) is recorded and logged in the system's nonvolatile memory (calibration process), and facilitates the Central Code Only operation.
Aimer Calibration FA - Aiming Write Coordinates. Writes specified coordinates into the factory non-volatile memory area. Use this command if you wish to override any other previously written; factory, user or custom calibration or setting. Examples shown use the terminal window tool provided within Datalogic Aladdin configuration utility (available from the Datalogic website), or any other serial terminal utility.
Auto Calibration To Auto Calibrate the scanner, do the following: 1. Position and steady the reader in front of a plain flat sheet of paper or surface at a Depth of Field (distance) that is most appropriate for the application. 2. Send the command $Fx. The reader will turn the aimer on for an instant, then beep.
Aimer Calibration NOTES 290 Gryphon™ I GFS4400
Appendix C Standard Defaults The most common configuration settings are listed in the “Default” column of the table below. Page references are also provided for feature descriptions and programming bar codes for each parameter. A column has also been provided for recording of your preferred default settings for these same configurable features. Table 42.
Standard Defaults Parameter Enable Character Default Your Setting Page Number ‘E’ 36 U.S.
Standard Defaults Parameter Default Your Setting Page Number DIGITAL OUTPUT Activation Event Disable 70 Deactivation Event Disable 71 005 = 500 msec 71 Closed 72 1 Second 73 Power-up Beep 75 After Decode 75 Good Read Beep Type Mono 76 Good Read Beep Frequency High 76 Good Read Beep Length 80 ms 77 Good Read Beep Volume High 78 Good Read LED Duration 300 ms 79 Operating Mode On Line 80 Phase Off Event Trigger Stop 81 5 = Timeout set for 5 seconds 81 Serial Start Cha
Standard Defaults Parameter Default Your Setting Page Number Aiming Off After Decoding 87 Green Spot Duration 300 ms 87 Mobile Phone Mode Enable 88 No Mobile Bias 88 Partial Label Reading Control Enable 89 Mirror Reading Mode Disable 89 Decode Negative Image Disable 90 Disable 91 Random Order 92 Disable 92 Enable only UPCA coupon decoding 95 Enable 96 Send 96 Don’t Expand 97 Transmit 97 2D Component Not Required 98 Enable 98 Send 99 2D Component Not Required 99
Standard Defaults Parameter GTIN Formatting Default Your Setting Page Number Disable 101 Enable 102 Send 102 EAN-13 Flag 1 Character Transmit 103 EAN-13 ISBN Conversion Disable 103 EAN-13 2D Component 2D Component Not Required 104 Disable 104 Enable 105 Send 105 Disable 106 2D Component Not Required 106 Disable 107 Two Modules 108 Disable P2, P5 and P8 109 70 ms 110 Disable 113 Enable 116 Calculate Std Check 116 Send 117 Don’t Transmit 118 Disable 118 Small Q
Standard Defaults Parameter Default Your Setting Page Number Code 39 Set Length 1 2 120 Code 39 Set Length 2 50 121 Disable 122 Disable 122 Don’t Send 123 Don’t Transmit 123 Disable 124 Code 39 Danish PPT Enable/Disable Disable 124 Code 39 LaPoste Enable/Disable Disable 125 Code 39 PZN Enable/Disable Disable 125 Enable 126 Don’t Expand 126 Code 128 Check Character Transmission Don’t Send 127 Code 128 Function Character Transmission Don’t Send 127 Code 128 Sub-Code Exch
Standard Defaults Parameter Default Your Setting Page Number ISBT 128 Force Concatenation Disable 133 ISBT 128 Concatenation Mode Static 134 200 msec 135 I 2 of 5 Enable/Disable Disable 136 I 2 of 5 Check Character Calculation Disable 137 Send 138 Variable 138 I 2 of 5 Set Length 1 6 139 I 2 of 5 Set Length 2 50 140 Disable 141 Disable 141 Standard 2 of 5 Enable/Disable Disable 142 Standard 2 of 5 Check Character Calculation Disable 142 Send 143 Variable 143 Standar
Standard Defaults Parameter IATA Check Character Transmission Default Your Setting Page Number Enable 150 Disable 151 Don’t Calculate 151 Send 152 Transmit 152 abcd/abcd 153 Codabar Start/Stop Character Match Don’t Require Match 153 Codabar Quiet Zones Small Quiet Zones on two sides 154 Variable 154 Codabar Set Length 1 3 155 Codabar Set Length 2 50 156 Disable 157 Disable 157 Static 157 200 msec 158 Disable 159 Disable 160 Check C and K 160 Send 161 Variable 1
Standard Defaults Parameter Default Your Setting Page Number GS1 DataBar™ Expanded GS1 DataBar™ Expanded Enable/Disable Disable 165 GS1 DataBar™ Expanded GS1-128 Emulation Disable 166 GS1 DataBar™ Expanded 2D Component 2D component not required 166 GS1 DataBar™ Expanded Length Control Variable 167 GS1 DataBar™ Expanded Set Length 1 1 168 GS1 DataBar™ Expanded Set Length 2 74 169 GS1 DataBar™ Limited Enable/Disable Disable 170 GS1 DataBar™ Limited GS1-128 Emulation Disable 170 2D
Standard Defaults Parameter Default Your Setting Page Number Enable Plessey std. check char.
Standard Defaults Parameter Default Your Setting Page Number PDF417 Set Length 1 1 201 PDF417 Set Length 2 2,710 202 Disable 203 Micro PDF AIM ID and label type 203 Variable 204 Micro PDF417 Set Length 1 1 204 Micro PDF417 Set Length 2 0366 205 QR Code Enable / Disable Enable 206 QR Code Length Control Variable 206 QR Code Set Length 1 1 207 QR Code Set Length 2 7,089 208 Micro QR Code Enable/Disable Disable 209 Micro QR Code Length Control Variable 209 Micro QR Code
Standard Defaults NOTES 302 Gryphon™ I GFS4400
Appendix D Sample Bar Codes The sample bar codes in this appendix are typical representations for their symbology types.
Sample Bar Codes 1D Bar Codes — continued Code 32 Codabar Code 93 Code 11 304 Gryphon™ I GFS4400
Sample Bar Codes GS1 DataBar™ GS1 DataBar™ variants must be enabled to read the bar codes below (see GS1 DataBar™ Omnidi- rectional on page 164).
Sample Bar Codes 2D Bar Codes Aztec Datamatrix ABCabc ABCabc China Sensible Code MaxiCode ABCabc PDF 417 Micro PDF 417 12345678 ABCabc QR Code Micro QR Code ABCabc ABCDEF Composite Codes DataBar™ Expanded Stacked Composite GS1-128 Composite 306 Gryphon™ I GFS4400
Appendix E Keypad Use the bar codes in this appendix to enter numbers as you would select digits/characters from a keypad.
Keypad 308 A B C D E F Gryphon™ I GFS4400
Appendix F Reserved Characters Reserved Characters Hex Value [SOH] 0x01 [BEL] 0x07 # 0x23 $ 0x24 0 0x30 3 0x33 B 0X42 D 0X44 E 0X45 F 0X46 R 0X52 S 0X53 h 0x68 i 0x69 s 0x73 t 0x74 [FF] 0xFF Notes Reserved Strings C[CR] 0x43 0x0D 01[CR] 0x30 0x31 0x0D 34[CR] 0x33 0x34 0x0D Product Reference Guide C can be used without [CR] or inside a string (not the first character) 309
NOTES 310 Gryphon™ I GFS4400
Appendix G Scancode Tables Control Character Emulation Control character emulation selects from different scancode tables as listed in this appendix. Each of the control character sets below are detailed by interface type in the tables. These apply to USB Keyboard platforms. Control Character 00 : Characters from 00 to 0x1F are sent as control character Ctrl+Keys, special keys are located from 0x80 to 0xA1.
Interface Type PC AT PS/2, USB-Keyboard or USB-Keyboard for APPLE Table 43.
Interface Type PC AT PS/2, USB-Keyboard or USB-Keyboard for APPLE — cont. Table 44. Scancode Set When Control Character is 02 0x x0 x1 x2 x3 x4 x5 X6 x7 x8 x9 xA xB Ar↓ Ar↑ Al↓ Al ↑ Cl ↓ Cl ↑ Cr ↓ Cr ↑ BS Tab S+ Tab Home F1 F2 F3 F5 ESC F7 xE xF Enter Ins Pg Up Pg Dwn 2x Space ! “ # $ % & ‘ ( ) * + , - .
Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode Table 45.
Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode — cont. Table 46.
Digital Interface Table 47.
IBM31xx 102-key Table 49.
IBM XT Table 51. Scancode Set When Control Character is 00 or 01 0x 1x X0 NULL C+@ DLE C(S)+P x1 SOH C(S)+A DC1 C(S)+Q x2 STX C(S)+B DC2 C(S)+R x3 ETX C(S)+C DC3 C(S)+S x4 EOT C+D DC4 C(S)+T x5 ENQ C(S)+E NAK C(S)+U x6 ACK C(S)+F SYN C(S)+V x7 BEL C(S)+G ETB C(S)+W x8 BS C(S)+H CAN C(S)+X x9 HT TAB EM C(S)+Y xA LF C(S)+J SUB C(S)+Z xB VT C(S)+K ESC Esc xC FF C(S)+L FS C(S)+\ xD CR Enter GS C+] xE SO C(S)+N RS C(S)+^ xF SI C(S)+O US C(S)+_ 2x Space ! “ # $ % & ‘ ( ) * + , - .
Microsoft Windows Codepage 1252 Windows-1252 is a character encoding of the Latin alphabet, used by default in the legacy components of Microsoft Windows in English and some other Western languages.
NOTES 320 Gryphon™ I GFS4400
ASCII Chart ASCII Char. Hex No. ASCII Char. Hex No. ASCII Char. Hex No. ASCII Char. Hex No. NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US 00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F SP ! “ # $ % & ’ ( ) * + , .