Operation Manual

Table Of Contents
Enter/Exit Programming Mode Reading Parameters
102
Gryphon™ I GD44XX
/
GBT4400/GM440X
Stand Illumination Control
Controls the illumination status while the reading mode is stand mode and the reader is
attempting to detect objects.
DEFAULT
$CSMIL00(CR)
Stand Illumination Control = OFF
$CSMIL01(CR)
Stand Illumination Control = ON
$CSMIL02(CR)
Stand Illumination Control = Dim
Motion Still Timeout
Motion Still Timeout specifies the waiting time after which no motions is detected. When no
motion is detected for period of time longer than the set Motion Still Timeout period, the
scanner assumes it is in a motionless condition. The selectable setting are from 500 to 25,500
milliseconds in 100 millisecond increments. The default is 2 seconds. This option relates to
such features and the Aimer On timing and Stand Mode Object Sense scanning with respect to
motion. See page 289 in "References" for detailed information on setting this feature.
$CMOTO/r
Select Motion Still Timeout Setting
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code
at
left followed by the digits from the Alphanumeric
characters in
Appendix D, Keypad representing your
desired character(s). End by scanning the ENTER/EXIT
bar c
ode again.
Make a mistake? Scan the CANCEL bar code to abort
and not sa
ve the entry string. You can then start again at
the beginning.
~
CANCEL
DEFAULT
14 = Motion Still Timeout for 2 seconds