Operation Manual
Table Of Contents
- Introduction
- Setup
- Configuration Using Bar Codes
- Configuration Parameters
- Global Interface Features
- RS-232 Interface
- RS-232/USB-Com Interfaces
- Keyboard Settings
- USB-OEM Interface
- IBM 46XX Interface
- Wand Emulation Interface
- Data Format
- Reading Parameters
- Double Read Timeout
- LED and Beeper Indicators
- Scanning Features
- Scan Mode
- Stand Mode Indication
- Stand Operation
- Pick Mode
- Stand Mode Sensitivity
- Stand Mode Illumination Off Time
- Scanning Active Time
- Stand Illumination Control
- Motion Still Timeout
- Flash On Time
- Flash Off Time
- Aiming Pointer
- Aiming Duration Timer
- Green Spot Duration
- Mobile Phone Mode
- Partial Label Reading Control
- Decode Negative Image
- Image Capture
- Corded Only Features
- Multiple Label Reading
- 1D Symbologies
- 1D Code Selection
- Disable All Symbologies
- Code EAN/UPC
- UPC-E
- GTIN Formatting
- EAN 13 (Jan 13)
- ISSN
- EAN 8 (Jan 8)
- UPC/EAN Global Settings
- Add-Ons
- Code 39
- Trioptic Code
- Code 32 (Ital Pharmaceutical Code)
- Code 39 CIP (French Pharmaceutical)
- Code 39 Danish PPT
- Code 39 LaPoste
- Code 39 PZN
- Code 128
- GS1-128
- Code ISBT 128
- Interleaved 2 of 5 (I 2 of 5)
- Interleaved 2 of 5 CIP HR
- Follett 2 of 5
- Standard 2 of 5
- Industrial 2 of 5
- Code IATA
- Codabar
- ABC Codabar
- Code 11
- GS1 DataBar™ Omnidirectional
- GS1 DataBar™ Expanded
- GS1 DataBar™ Limited
- Code 93
- MSI
- Plessey
- 2D Symbologies
- WIRELESS FEATURES
- Bluetooth-Only Features
- FEATURES FOR STAR MODELS ONLY
- Motion Features
- References
- Message Formatting
- Technical Specifications
- Standard Defaults
- Sample Bar Codes
- Keypad
- Scancode Tables
Code 93 Enter/Exit Programming Mode
Product Reference Guide
193
Code 93 Set Length 2
This feature specifies one of the bar code lengths for Code 93 Length Control. Length 2 is the
maximum label length if in Variable Length Mode, or the second fixed length if in Fixed Length
Mode. Length includes the bar code’s check, data, and full-ASCII shift charac
ters. The length
does not include start/stop characters. The length can be set from 1 to 50 characters. A setting of
0 specifies to ignore this length (only one fixed length).
Table 20 provides examples for setting Length 2. See page 267 for detailed instructions on
setting this feature.
Table 20. CODE 93 Length 2 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
00 (Ignore This
Len
gth)
07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT CODE 93 LENGTH 2 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘0’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
$CC9L2
Select Code 93 Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
50 = Length 2 is 50 Characters