China Sensible Code Enter/Exit Programming Mode
Product Reference Guide
209
China Sensible Code
China Sensible Code Enable / Disable
Enables/disables the ability of the reader to decode China Sensible Code labels.
DEFAULT
$CCSEN00(CR)
China Sensible Code = Disable
$CCSEN01(CR)
China Sensible Code = Enable
China Sensible Code Length Control
This feature specifies either variable length decoding or fixed length decoding for this
symbology.
Variable Length:
For variable length decoding, a minimum and maximum length may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
DEFAULT
$CCSLC00(CR)
China Sensible Code Length Control = Variable Length
$CCSLC01(CR)
China Sensible Code Length Control = Fixed Length