Operation Manual
Table Of Contents
- Introduction
- Setup
- Configuration Using Bar Codes
- Configuration Parameters
- Global Interface Features
- RS-232 Interface
- RS-232/USB-Com Interfaces
- Keyboard Settings
- USB-OEM Interface
- IBM 46XX Interface
- Wand Emulation Interface
- Data Format
- Reading Parameters
- Double Read Timeout
- LED and Beeper Indicators
- Scanning Features
- Scan Mode
- Stand Mode Indication
- Stand Operation
- Pick Mode
- Stand Mode Sensitivity
- Stand Mode Illumination Off Time
- Scanning Active Time
- Stand Illumination Control
- Motion Still Timeout
- Flash On Time
- Flash Off Time
- Aiming Pointer
- Aiming Duration Timer
- Green Spot Duration
- Mobile Phone Mode
- Partial Label Reading Control
- Decode Negative Image
- Image Capture
- Corded Only Features
- Multiple Label Reading
- 1D Symbologies
- 1D Code Selection
- Disable All Symbologies
- Code EAN/UPC
- UPC-E
- GTIN Formatting
- EAN 13 (Jan 13)
- ISSN
- EAN 8 (Jan 8)
- UPC/EAN Global Settings
- Add-Ons
- Code 39
- Trioptic Code
- Code 32 (Ital Pharmaceutical Code)
- Code 39 CIP (French Pharmaceutical)
- Code 39 Danish PPT
- Code 39 LaPoste
- Code 39 PZN
- Code 128
- GS1-128
- Code ISBT 128
- Interleaved 2 of 5 (I 2 of 5)
- Interleaved 2 of 5 CIP HR
- Follett 2 of 5
- Standard 2 of 5
- Industrial 2 of 5
- Code IATA
- Codabar
- ABC Codabar
- Code 11
- GS1 DataBar™ Omnidirectional
- GS1 DataBar™ Expanded
- GS1 DataBar™ Limited
- Code 93
- MSI
- Plessey
- 2D Symbologies
- WIRELESS FEATURES
- Bluetooth-Only Features
- FEATURES FOR STAR MODELS ONLY
- Motion Features
- References
- Message Formatting
- Technical Specifications
- Standard Defaults
- Sample Bar Codes
- Keypad
- Scancode Tables
Enter/Exit Programming Mode Motion Features
254
Gryphon™ I GD44XX
/
GBT4400/GM440X
Motion Sensitivity
Defines discrete set of levels for scanner motion sensitivity when in handheld use.
$CMOSY00(CR)
Motion Sensitivity = Low
$CMOSY01(CR)
Motion Sensitivity = Medium
DEFAULT
$CMOSY02(CR)
Motion Sensitivity = High
Motionless Timeout
Specifies the waiting time in 100 millisecond ticks to assume that the reader is in a motionless
condition. The selectable range is 500 msec to 25.5 Seconds. When no motion event is detected
for a period of time longer than this timeout, the software assumes the reader is in a motionless
condition. This normally results in returning the scanner to Stand Mode. This option relates to
such features as Aimer On and Stand Mode Object Sense scanning with respect to motion. See
"Motionless Timeout" on page 289 in References.
$CMOTO
Select Motionless Timeout Setting
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code
at
left followed by three digits from the Alphanumeric
characters in
Appendix D Keypad representing your
desired character(s). End by scanning the ENTER/EXIT
bar c
ode again.
Make a mistake? Scan the CANCEL bar code to abort
and not sa
ve the entry string. You can then start again at
the beginning.
~
CANCEL
DEFAULT
020 = Motionless Timeout = 2 seconds