RS-232 Parameters
Product Reference Guide
263
Enable Character
Specifies the value of the RS-232 host command used to enable the reader.
ASCII characters or any hex value from 0 to
0xFF can be selected.
Setting to previously defined characters such as XON, XOFF, or host
commands conflicts with normal operation of these characters. 8-
bit data is not recognized when the option
Data Bits
has been set
as 7 Data Bits.
To set this feature:
Determine the desired character or value. A setting of
0xFF indicates the Enable Character is
not used (not available).
1. Determine the desired character or v
alue.
2. Use the ASCII Chart on the inside back cover of this manual to find the hex equivalent
for the desired character/value.
3. Go to page 53 and scan the ENTER/EXIT PROGRAMMING MODE bar code to enter
Programming Mode.
4. Scan the bar code: SELECT ENABLE CHARACTER SETTING.
5. Scan the appropriate two alphanumeric
characters
from the keypad in Appendix D, Key-
pad, that represent the desired character/value in step 2 above. The second character will
cause a two-beep indication.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming
Mod
e.
This completes the procedure. See Tabl e 31 for some examples of how to set this feature.
Table 31. Enable Character Setting Examples
STEP ACTION EXAMPLES
1 Desired character/value
‘e ‘}’ ‘E’
Enable Command
Not Used
2
Hex equivalent from
ASCII
Chart
0x65 0x7D 0x45 0xFF
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT ENABLE CHARACTER VALUE SETTING
5
Scan Two Characters From
Appendix D, Keypad
‘6’ and ‘5’ ‘7’ and ‘D’ ‘4’ and ‘5’ ‘F’ AND ‘F’
6 Scan ENTER/EXIT PROGRAMMING MODE