Operation Manual
Table Of Contents
- Introduction
- Setup
- Configuration Using Bar Codes
- Configuration Parameters
- Global Interface Features
- RS-232 Interface
- RS-232/USB-Com Interfaces
- Keyboard Settings
- USB-OEM Interface
- IBM 46XX Interface
- Wand Emulation Interface
- Data Format
- Reading Parameters
- Double Read Timeout
- LED and Beeper Indicators
- Scanning Features
- Scan Mode
- Stand Mode Indication
- Stand Operation
- Pick Mode
- Stand Mode Sensitivity
- Stand Mode Illumination Off Time
- Scanning Active Time
- Stand Illumination Control
- Motion Still Timeout
- Flash On Time
- Flash Off Time
- Aiming Pointer
- Aiming Duration Timer
- Green Spot Duration
- Mobile Phone Mode
- Partial Label Reading Control
- Decode Negative Image
- Image Capture
- Corded Only Features
- Multiple Label Reading
- 1D Symbologies
- 1D Code Selection
- Disable All Symbologies
- Code EAN/UPC
- UPC-E
- GTIN Formatting
- EAN 13 (Jan 13)
- ISSN
- EAN 8 (Jan 8)
- UPC/EAN Global Settings
- Add-Ons
- Code 39
- Trioptic Code
- Code 32 (Ital Pharmaceutical Code)
- Code 39 CIP (French Pharmaceutical)
- Code 39 Danish PPT
- Code 39 LaPoste
- Code 39 PZN
- Code 128
- GS1-128
- Code ISBT 128
- Interleaved 2 of 5 (I 2 of 5)
- Interleaved 2 of 5 CIP HR
- Follett 2 of 5
- Standard 2 of 5
- Industrial 2 of 5
- Code IATA
- Codabar
- ABC Codabar
- Code 11
- GS1 DataBar™ Omnidirectional
- GS1 DataBar™ Expanded
- GS1 DataBar™ Limited
- Code 93
- MSI
- Plessey
- 2D Symbologies
- WIRELESS FEATURES
- Bluetooth-Only Features
- FEATURES FOR STAR MODELS ONLY
- Motion Features
- References
- Message Formatting
- Technical Specifications
- Standard Defaults
- Sample Bar Codes
- Keypad
- Scancode Tables
Product Reference Guide
301
Table 52
Programming Mode - The following indications ONLY occur when the reader is in Programming Mode.
Label Program-
ming Mode Entry
A valid programming label has
been scanned.
LED blinks continuously
Reader sounds four low fre-
quency beeps.
Label Program-
ming Mode
Reject
ion of Label
A label has been rejected.
N/A
Reader sounds three times at
lowest frequency & current vol-
ume.
Label Program-
ming Mode
A
c
ceptance of
Partial Label
In cases where multiple labels
must be scanned t
o program one
feature, this indication acknowl-
edges each portion as it is suc-
cessfully scanned.
N/A
Reader sounds one short beep
at highest fr
equency & current
volume.
Label Program-
ming Mode
Ac
ceptance of
Programming
Configuration option(s) have
been successfully pr
ogrammed
via labels and the reader has
exited Programming Mode.
N/A
Reader sounds one high fre-
quency beep and 4 low fre-
quency beeps followed by reset
beep
s.
Label Program-
ming Mode Can-
cel Item Entry
Cancel label has been scanned.
N/A
Reader sounds two times at low
frequency and current volume.
. Programming Mode Indications
Error Codes
Upon startup, if the reader sounds a long tone, this means the reader has not passed its
automatic Selftest and has entered FRU (Field Replaceable Unit) isolation mode. If the reader is
reset, the sequence will be repeated. The following table describes the LED flashes/beep codes
associated with an error found.
NUMBER OF LED
FLASHES/BEEPS
ERROR
All Mode
ls:
GD44XX, GBT4400, GM44XX
CORRECTIVE ACTION
1 Configuration
Contact Helpdesk for assis-
tance
2 Interface PCB
6 Digital PCB
12 Imager
15 Accelerometer