Operation Manual
Table Of Contents
- Introduction
- Setup
- Configuration Using Bar Codes
- Configuration Parameters
- Global Interface Features
- RS-232 Interface
- RS-232/USB-Com Interfaces
- Keyboard Settings
- USB-OEM Interface
- IBM 46XX Interface
- Wand Emulation Interface
- Data Format
- Reading Parameters
- Double Read Timeout
- LED and Beeper Indicators
- Scanning Features
- Scan Mode
- Stand Mode Indication
- Stand Operation
- Pick Mode
- Stand Mode Sensitivity
- Stand Mode Illumination Off Time
- Scanning Active Time
- Stand Illumination Control
- Motion Still Timeout
- Flash On Time
- Flash Off Time
- Aiming Pointer
- Aiming Duration Timer
- Green Spot Duration
- Mobile Phone Mode
- Partial Label Reading Control
- Decode Negative Image
- Image Capture
- Corded Only Features
- Multiple Label Reading
- 1D Symbologies
- 1D Code Selection
- Disable All Symbologies
- Code EAN/UPC
- UPC-E
- GTIN Formatting
- EAN 13 (Jan 13)
- ISSN
- EAN 8 (Jan 8)
- UPC/EAN Global Settings
- Add-Ons
- Code 39
- Trioptic Code
- Code 32 (Ital Pharmaceutical Code)
- Code 39 CIP (French Pharmaceutical)
- Code 39 Danish PPT
- Code 39 LaPoste
- Code 39 PZN
- Code 128
- GS1-128
- Code ISBT 128
- Interleaved 2 of 5 (I 2 of 5)
- Interleaved 2 of 5 CIP HR
- Follett 2 of 5
- Standard 2 of 5
- Industrial 2 of 5
- Code IATA
- Codabar
- ABC Codabar
- Code 11
- GS1 DataBar™ Omnidirectional
- GS1 DataBar™ Expanded
- GS1 DataBar™ Limited
- Code 93
- MSI
- Plessey
- 2D Symbologies
- WIRELESS FEATURES
- Bluetooth-Only Features
- FEATURES FOR STAR MODELS ONLY
- Motion Features
- References
- Message Formatting
- Technical Specifications
- Standard Defaults
- Sample Bar Codes
- Keypad
- Scancode Tables
Setup Customizing Configuration Settings
34
Gryphon™ I GD44XX
/
GBT4400/GM440X
Resetting the Product Configuration to Defaults
Restore Custom Defaults
If you aren’t sure what programming options are in your imager, or you’ve changed some
options and want to restore the Custom Default Configuration that may have been saved in the
scanner, scan the Restore Custom Default Configuration bar code below. This will restore the
custom configuration for the currently active interface.
Restore Custom Default Configuration
$P,HA00,P(CR)
Custom defaults are based on the interface type. Configure the imager
for the correct interface before scanning this label.
Restore Factory Configuration
If you want to restore the Factory Configuration for your imager, scan either the Restore USA
Factory Configuration bar code or the Restore EU Factory Configuration bar code below. Both
labels restore the scanner configuration to the factory settings, including the interface type. The
USA label restores Label IDs to those historically used in the USA. The EU label restores Label
IDs to those historically used in Europe. The Label ID sets for USA and EU are shown in the
“Label ID Control” section on page 81
of this manual.
$P,AE,P(CR)
Restore USA Factory Configuration
$P,Ae,P(CR)
Restore EU Factory Configuration
The programming items listed in the following sections show the factory default settings for
each of the menu commands.