ACK NAK Timeout Value
This option specifies the amount of time the reader waits for an ACK character from the host following label
transmission. The selectable timeout range is 200 milliseconds to 15,000ms (15 seconds) in 200ms increments. A
selection of 0 disables the timeout.
See page 260 for more information on setting this feature.
$CR2AT
Select ACK NAK Timeout Value Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the
bar code at left followed by the digits from the
Alphanumeric characters in Appendix D, Keypad
representing your desired character(s). End by
scanning the ENTER/EXIT
bar code again.
Make a mistake? Scan the CANCEL bar code to
abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
01 ACK NAK Timeout value is 200ms
ACK NAK Retry Count
This feature specifies the number of times the reader retries a label transmission due to a retry condition. The
selectable range is from 1 to 254 retries. A selection of 0 disables the count, and a selection of 255 specifies
unlimited retries. See page 261 for more information.
$CR2AR
Select ACK NAK Retry Count Setting
To configure this feature, scan the ENTER/EXIT
PROGRAMMING MODE bar code above, then the
bar code at left followed by the digits from the
Alphanumeric characters in Appendix D, Keypad
representing your desired character(s). End by
scanning the ENTER/EXIT
bar code again.
Make a mistake? Scan the CANCEL bar code to
abort and
not save the entry string. You can then start again at the
beginning.
~
CANCEL
DEFAULT
003 = 3 Retries