Operation Manual

Table Of Contents
Enter/Exit Programming Mode IBM 46XX Interface
70
Gryphon™ I GD44XX
/
GBT4400/GM440X
Transmit Labels in Code 39 Format
This feature enable/disables translation to Code 39 before transmitting label data to an IBM-
46XX or a USB-OEM host. Only the symbology identifier is modified for the translation. The
data is not converted to Code 39 or verified to be valid for Code 39.
Options are:
IBM Standard Format:
Send labels in standard IBM format.
Code 39 Format:
Translate the following symbologies to Code 39:
USB-OEM: Code128, Code 93, and Codabar
IBM-Port 5B: Code 128, Code 93, and Codabar
IBM-Port 9B: Code 93 and Codabar
DEFAULT
$CIBC300(CR)
Transmit Labels in Code 39 Format =
IBM Standard Format
$CIBC301(CR)
Transmit Labels in Code 39 Format = Code 39 Format
Interface Options
$CIFO101(CR)
Obey Scanner Configuration Host Commands
$CIFO102(CR)
Ignore Scanner Configuration Host Commands
DEFAULT
This feature provides for an interface-specific control mechanism.