Specifications

HOST CONFIGURATION STRINGS
115
A
CODE SELECTION (continued)
DESCRIPTION STRING
Codabar disable Codabar family
AD0
Standard no start/stop character equality control
nor transmission
AD111
no start/stop character equality control
but transmission
AD112
start/stop character equality control
but no transmission
AD121
start/stop character equality control
and transmission
AD122
ABC Codabar no start/stop character equality control
but transmission
AD212
Codabar ABC forced concatenation
AD232
code length
AD*xxxx
start/stop character case in
transmission
lower case
ADA0
upper case
ADA1
Code 128 disable Code 128 family
AI0
enable Code 128 - control without transmission of check digit
AI11
enable EAN 128 - control without transmission of check digit
AI21
ISBT 128 enable ISBT 128
AI31
define EAN 128 separator character
EPx
EAN 128 separator character disable
Aa0
enable
Aa1
add first GS in EAN 128 disable
EQ0
enable
EQ1
Code 93 disable Code 93 family
AK0
enable Code 93 - control without transmission of check digit
AK1
Codablock-A disable
AO0
enable
AO1
Codablock-F disable the family
AN0
enable Standard
AN1
enable EAN
AN2
x = for RS232: Hex value from 00 to 7F
x = for WEDGE: Hex value from 00 to 9B
xxxx = ASCII numbers that define the code length where:
First 2 digits = minimum acceptable code length.
Second 2 digits = maximum acceptable code length.
The minimum code length must always be less than or equal to the maximum. The maximum
code lengths are 99 characters.
Examples:
0132 = variable length from 1 to 32 digits in the code.
1010 = 10 digit code length only.