Specifications

Enter Configuration Exit and Save Configuration
ik
ik
CODE SELECTION
i k
i k
63
DEFINE EAN 128 SEPARATOR CHARACTER
Code EAN 128 uses a special character to separate a variable length code field from the next
code field. The standard value of this character (from code EAN 128 specifications) is ASCII
<GS> which is not useful for the Wedge and RS232 interface.
For this reason it can be modified by the user:
GS substitution character
i&1 k
i&1 k
i&1 k
After selecting the code, read one character from the HEX table.
Valid range of characters for RS232 Interface = 00-7F
Valid range of characters for WEDGE Interface = 00-9B
NOTE
For Enhanced Architecture readers refer to the Character Replacement
parameter in Data Format to manage the GS separator character.
EAN 128 SEPARATOR CHARACTER
GS substitution character disabled
i"Bk
i"Bk
i"Bk
GS substitution character enabled
i"Bk
i"Bk
i"Bk
NOTE
For Enhanced Architecture readers refer to the Character Replacement
parameter in Data Format to manage the GS separator character.