User's Manual

USE AND FUNCTIONING
75
3
3.16 FIRMWARE UPDATE
The Datalogic JOYA™ X2 is equipped with a tool that implements a firmware
update service.
This tool, called Datalogic Updater (DLUpdater), is compatible with all
hardware versions of the Datalogic WindowsCE 6.0 models:
An update can be explicitly invoked by running the application DLUpdater.exe,
provided together with the update file DLUpdate.zip. The update must be
contained in the root.
It is advisable, even if not binding, to connect the terminal to
an external power source before starting the update
process. This prevents the terminal from turning off while
running and avoids a corruption of flash content.
CAUTION
After the update process, all the data stored in the backup
folder could be irreparably lost, as well as the device
configuration (even that one stored in persistent memory).
Therefore, before starting a firmware update it is advisable
to run a backup copy of the data you want to preserve on
PC (e.g. using ActiveSync or Windows Mobile Device
Center Connection).
CAUTION
3.16.1 Retrieving a Firmware Image Update
The following instructions use Internet Explorer to retrieve the most current
firmware image.
1. Launch Internet Explorer on your PC and navigate to
http://www.adc.datalogic.com..
2. Navigate the Downloads section of the web site.
3. Select the product, desired language, and software updates. Click Go!
4. Select the file you want to download, then click Save and navigate to the
location where you want to save the firmware files.
5. Click Save again to begin copying the files to your local machine (or local
network location).