Kyman-NET™ User’s Manual
Kyman-NET™ USER'S MANUAL
DATALOGIC S.p.A. Via Candini 2 40012 - Lippo di Calderara di Reno Bologna - Italy Kyman-NET™ - User's Manual Ed.: 12/2006 ALL RIGHTS RESERVED Datalogic reserves the right to make modifications and improvements without prior notification. Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or consequential damages resulting from the use of this material.
CONTENTS DATALOGIC END USER LICENSE AGREEMENT..................................... v REFERENCES ........................................................................................... vii Conventions .................................................................................................vii Reference Documentation ...........................................................................vii Services and Support...................................................................................
3.5 3.5.1 3.5.2 3.6 3.6.1 3.6.2 3.7 3.7.1 3.7.2 3.7.3 3.7.4 3.7.5 3.8 3.8.1 3.8.2 3.8.3 3.9 Status Indicators ......................................................................................... 24 LED Status.................................................................................................. 24 Taskbar ....................................................................................................... 25 Data Capture Configuration ......................................................
DATALOGIC END USER LICENSE AGREEMENT BY DOWNLOADING OR INSTALLING THE SOFTWARE, OR BY USING DATALOGIC EQUIPMENT THAT INCLUDES THIS SOFTWARE, YOU ARE CONSENTING TO BE BOUND BY THIS AGREEMENT. IF YOU DO NOT AGREE TO ALL OF THE TERMS OF THIS AGREEMENT, THEN DO NOT DOWNLOAD, INSTALL, USE THE SOFTWARE NOR DATALOGIC EQUIPMENT.
6. Limited Warranty. If Customer obtained the Software directly from Datalogic, then Datalogic warrants that during the Warranty Period (as defined below): (i) the media on which the Software is furnished will be free of defects in materials and workmanship under normal use; and (ii) the Software will substantially conform to its published specifications.
REFERENCES CONVENTIONS This manual uses the following conventions: “User” refers to anyone using a Kyman-NET™ mobile computer. “Mobile computer” and "Kyman-NET™" refer to Kyman-NET™ mobile computer. “You” refers to the System Administrator or Technical Support person using this manual to install, configure, operate, maintain or troubleshoot a Kyman-NET™ mobile computer. REFERENCE DOCUMENTATION For further information regarding Kyman-NET™ refer to the SDK Help on-Line.
SAFETY REGULATIONS NOTE Read this manual carefully before performing any type of connection to the Kyman-NET™ mobile computer. The user is responsible for any damages caused by incorrect use of the equipment or by inobservance of the indication supplied in this manual. GENERAL SAFETY RULES − Use only the components supplied by the manufacturer for the specific Kyman-NET™ being used.
LASER SAFETY The laser light is visible to the human eye and is emitted from the window indicated in the figure. This information applies to both laser models and the Kyman-NET™ Imager Aiming System. Laser output window This product complies with 21 CFR Subchapter J AVOID EXPOSURE LASER LIGHT IS EMITTED FROM THIS APERTURE LASER LIGHT - DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT MAX. OUTPUT RADIATION 1.
ENGLISH The following information is provided to comply with the rules imposed by international authorities and refers to the correct use of your mobile computer. STANDARD LASER SAFETY REGULATIONS This product conforms to the applicable requirements of both CDRH 21 CFR 1040 and EN 60825-1 at the date of manufacture. For installation, use and maintenance, it is not necessary to open the device.
DEUTSCH Die folgenden Informationen stimmen mit den Sicherheitshinweisen überein, die von internationalen Behörden auferlegt wurden, und sie beziehen sich auf den korrekten Gebrauch vom Terminal. NORM FÜR DIE LASERSICHERHEIT Dies Produkt entspricht am Tag der Herstellung den gültigen EN 60825-1 und CDRH 21 CFR 1040 Normen für die Lasersicherheit. Es ist nicht notwendig, das Gerät wegen Betrieb oder Installations-, und Wartungsarbeiten zu öffnen.
ESPAÑOL Las informaciones siguientes son presentadas en conformidad con las disposiciones de las autoridades internacionales y se refieren al uso correcto del terminal. NORMATIVAS ESTÁNDAR PARA LA SEGURIDAD LÁSER Este aparato resulta conforme a las normativas vigentes de seguridad láser a la fecha de producción: CDRH 21 CFR 1040 y EN 60825-1. No es necesario abrir el aparato para la instalación, la utilización o la manutención.
RADIO COMPLIANCE In radio systems configured with mobile computers and access points, the frequencies to be used must be allowed by the spectrum authorities of the specific country in which the installation takes place. Be absolutely sure that the system frequencies are correctly set to be compliant with the spectrum requirements of the country. The Radio modules used in this product automatically adapt to the frequencies set by the system and do not require any parameter settings.
ESPAÑOL Contacta la autoridad competente para la gestión de los dispositivos de radio frecuencia de tu país, para verificar cualesquiera restricciones o licencias posibles requerida. Además se puede encontrar mas información en el sitio web: http://europa.eu.int/comm/enterprise/rtte/spectr.htm. FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment. This device complies with PART 15 of the FCC Rules.
GENERAL VIEW B D E C I A J K F G L H A) B) C) D) E) F) Backlit display G) User programmable LED H) Speaker I) Good read LED J) Charging status and battery low K) warning LED Scan key L) Keyboard Microphone Laser safety label Product label Adjustable elastic strap with stylus holders Battery pack N M M) Data capture/Laser Output window N) Communication/Charger/Headset connector xv
xvi
INTRODUCTION 1 1.1 1 INTRODUCTION KYMAN-NET™ DESCRIPTION The Datalogic Kyman-NET™ rugged mobile computer is one of the key elements of Datalogic’s mobile@work™ product family for logistic solutions. Kyman-NET™, thanks to the lightest weight of its category combined with one of the best ergonomics ever seen on the market, reduces the operators fatigue with no compromises in terms of reliability and robustness.
KYMAN-NET™ 1 1.2 AVAILABLE MODELS The brand new Kyman-NET™ is available in different models depending on the options it is equipped with. All options are listed below: • • • data capture options: laser, imager, RfId, laser + RfId, laser extra-long range communication options: Wi-Fi 802.11b, GSM/GPRS, Bluetooth® data entry options: alphanumeric keyboard, numeric keyboard For further details about the Kyman-NET™ models refer to the web site: http://www.datalogic.com. 1.
INTRODUCTION 1 Rechargeable battery packs are not initially charged. Therefore the first operation to perform is to charge them. See paragraph 4.1. NOTE 1.3.1 Using the Belt Clip To use the belt clip, proceed as follows: 1. Remove the elastic strap and unscrew the strap pivot. 2. Release the belt clip pivot by pressing the belt clip unlock button.
1 KYMAN-NET™ 3. Screw the belt clip pivot on the terminal by using the fixing screw. 4. Insert the terminal in the belt clip by sliding the belt clip pivot into the belt clip until it clicks into place. 5. To release the terminal, press the belt clip unlock button.
INTRODUCTION 1.4 1 ACCESSORIES Cradles 94A151101 Kyman-NET™ Single Cradle Desk (includes slot for spare battery pack recharge; RS232 and USB communications) 94A151107 Kyman-NET™ Vehicle Cradle Charger 94A151102 Kyman-NET™ Multi-Battery Pack Charger (4 slots) Batteries 94ACC1302 Kyman-NET™ Standard Battery Pack (Li-Ion battery pack 2200 mAh@7.
KYMAN-NET™ 2 2 CONNECTIONS 2.1 CONNECTION TO THE HOST COMPUTER 2.1.1 RS232/USB Direct Connection You can use a cable to connect the Kyman-NET™ to a host computer to transfer data. Key: A B Host computer Kyman-NET™ C RS232 cable or USB cable Host computer Kyman-NET™ C D RS232 cable or USB cable Power Supply* Key: A B * Recommended Power Supply: FPS18 AC/DC Power Supply (94ACC4595). CAUTION 6 USB communication may not be completely guaranteed while batteries are simultaneously in charge.
CONNECTIONS 2.1.2 2 WLAN Connection Kyman-NET™ Wi-Fi models can communicate with the host using the on-board radio frequency module and an Access Point connected to the host computer. A B C Key: A) Kyman-NET™ B) Access point C) Host – Application Server NOTE In order to avoid wasting power, the Wi-Fi module is off by default. If you need to have the Wi-Fi module working, the module must be powered on using the Wireless Communications applet (see par. 3.7.4).
KYMAN-NET™ 2 2.1.3 WPAN Connections Kyman-NET™ mobile computers can communicate with a Bluetooth® device, such as ® a printer, within a range of 10 m, using the on-board Bluetooth module. A B Key: A) Kyman-NET™ ® B) Bluetooth printer NOTE 8 In order to avoid wasting power, the Bluetooth® module is off by default. If you need to have Bluetooth® working, the module must be powered on using the Wireless Communications applet (see par. 3.7.4), and perform the Discovery procedure (see par. 3.8.2).
CONNECTIONS 2.1.4 2 WWAN Connections Kyman-NET™ GSM/GPRS models enhance your connectivity solutions giving you an opening to an international wireless infrastructure that is the standard in Europe and Asia. GSM (Global System for Mobile communications), is a digital mobile phone system based on TDMA; it utilizes the 900, 1800 and 1900 MHz bands. GPRS supports IP (Internet Protocol) and allows accessing Internet and Intranet services, such as sending and receiving e-mail or Web browsing.
KYMAN-NET™ 2 Installing the SIM Card SIM Protection Cover Battery Contacts To correctly insert the SIM Card, proceed as follows: 1- Turn off the Kyman-NET™ mobile computer. 2- Pull the battery latch down as indicated in the next figure and remove the battery pack. 3- Open the Sim Card slot by unscrewing the two protection cover screws (A, B). A B SIM Card Slot 4- Position the SIM Card with its contacts downwards, place the protection cover on the slot and close it with the two fixing screws.
CONNECTIONS 2.2 2 CONNECTION CABLES The following cables are listed with their order number.
KYMAN-NET™ 2 RS232 Direct Connection: 94A051014 WIN-NET SERIAL PWR CABLE (HRS 3500-16P-CV) Kyman-NET™ side 16-pin RX TX 5 6 TX 3 RX HOST/PC side 9-pin (female) 2 CTS 7 RTS CD DSR DSR DTR CTS 1 8 9 10 8 GND 1 4 13 5 VALIM 2 3 6 GND GND GND POWER CONNECTOR USB Direct Connection: 94A051015 WIN-NET USB PWR CABLE (HRS 3500-16P-CV) SHIELD HOUSING 14 V+ 16 D(-) 15 D(+) HOUSING 1 2 3 3 GND 4 4 13 1 2 POWER VALIM Power Supply Polarity: VEXT GND 12
USE AND FUNCTIONING 3 3 USE AND FUNCTIONING The use of the Kyman-NET™ depends on the application software loaded. However there are several parameters that can be set and utilities that can be used to perform some basic functions such as data capture, communications, file management, etc. 3.1 STARTUP The Kyman-NET™ turns on when the battery pack or the external supply is inserted. After the battery pack is installed, use the [ON/OFF] key to turn the mobile computer on and off.
KYMAN-NET™ 3 The mobile computer goes into power-off (low power with display and keyboard backlight off), when it is no longer used for more than a programmable timeout, which is defined in the POWER applet of the Control Panel. In this mode it can be awakened (resuming operation) by the [ON/OFF] key. The mobile computer can also be awakened or turned off by the application program. NOTE 3.2 USING THE STYLUS The stylus selects items and enters information. The stylus functions like a mouse.
USE AND FUNCTIONING 3.3 3 DATA CAPTURE To configure and enable data capture parameters refer to par. 3.6. 3.3.1 Laser Data Capture To scan barcodes, point the Kyman-NET™ laser model onto the code from a distance within the reading range while pressing the SCAN key. See the reading diagrams in par. 5.2 for the reading range of your model. The lighted band emitted by the laser must completely intercept the barcode as shown in the figure below.
KYMAN-NET™ 3 3.3.2 Imager Data Capture To read a 1D or 2D code, simply point the Kyman-NET™ Imager model onto the code from a distance within the reading range (See par. 5.1, section Kyman-NET™ Imager Optical Features) and press the SCAN key.
USE AND FUNCTIONING 3 A red beam illuminates the code, which is captured and decoded. You will get a good read. Linear barcode 2D Matrix symbol ÌBX3ÉÎ Relative Size and Location of Aiming System Pattern The field of view changes its size as you move the reader closer or farther away from the code. The field of view indicated by the aiming system pattern will be smaller when the Kyman-NET™ Imager is closer to the code and larger when it is farther from the code.
KYMAN-NET™ 3 3.4 DESCRIPTION OF THE KEYS The Kyman-NET™ provides two different keyboards, an alphanumeric keyboard and a numeric keyboard, having a total of respectively 53 and 36 keys. 3.4.1 Alphanumeric Keyboard (53-key Model) The following image shows the Alhanumeric keyboard.
USE AND FUNCTIONING 3 Main Keys Function KEY FUNCTION It starts data capture. They let you move forwards, backwards, upwards or downwards within text fields, scroll through a Menu list or browse among folder files. After a yellow modifier key press, they let you scroll the pages up and down. After a blue modifier key press, the blue arrows allow moving forwards or backwards within the Internet Explorer browser pages.
KYMAN-NET™ 3 Special Function Icons ICON FUNCTION After a yellow modifier key press, it opens the Start menu. After a yellow modifier key press, it opens the file manager. After a yellow modifier key press, it switches ON/OFF the keyboard backlight. After a yellow modifier key press, it locks and unlocks the keyboard. Hardware and Software Reset By pressing these keys simultaneously, a system hardware reset is performed. By pressing these keys simultaneously, a system software reset is performed.
USE AND FUNCTIONING 3.4.2 3 Numeric Keyboard (36-key Model) Main Keys Function KEY FUNCTION It starts data capture. They let you move forwards, backwards, upwards or downwards within text fields, scroll through a Menu list or browse among folder files.
KYMAN-NET™ 3 After a yellow modifier key press, they let you scroll the pages up and down. After a blue modifier key press, the blue arrows allow moving forwards or backwards within the Internet Explorer browser pages. Yellow modifier: when pressed before a standard key, it enables the function printed in yellow above the key. Blue modifier: when pressed before a standard key, it enables the function printed in blue above the key. When pressed, it toggles the alphanumeric/numeric modes.
USE AND FUNCTIONING 3 Keys from 1 to 9 share the following behavior scheme: B A A. B. Function of the key when directly pressed Function of the key when in Alpha mode. When in Alpha mode press the key until the desired letter is shown. The letter is entered if you wait for a short timeout or if you press a different key. Special Function Icons ICON FUNCTION It opens the file manager. It switches ON/OFF the keyboard backlight.
KYMAN-NET™ 3 3.5 3.5.1 STATUS INDICATORS LED Status The Kyman-NET™ provides three different LEDs signaling the mobile computer status. LED STATUS General Purpose (left-side) Green/Red This LED is available to the application program. Charging Status and Green constant Battery Low Warning It is constant once the charging process has been completed.
USE AND FUNCTIONING 3.5.2 3 Taskbar The Taskbar provides information about the time, the battery level, the keyboard function, and the decoding status. ICONS DESCRIPTION Time and Battery Icons It displays the time. They are representative of five different icons indicating the battery level. The icon is partially green when the power left is >20% and partially red colored when the power left is <20%. It indicates that the battery is charging.
KYMAN-NET™ 3 3.6 DATA CAPTURE CONFIGURATION From the Taskbar, tap the "Data Capture" icon to open a drop–down menu. Data Capture can also be accessed from the Control Panel. By selecting the Info item from this drop-down menu you can access information about the Scanner and the Software; the Configure item opens the configuration applet (Data Capture Configuration Window), while Capture accesses the data capture applet (Data Capture Window), which enables code reading.
USE AND FUNCTIONING 3 Data Capture Configuration Window The screen format shows two columns where the left column indicates branches or parameters. Branches have three dots in the right column (...). You can navigate through the tree structure using the stylus or keyboard arrows directly on the item field or from the menu. Parameters have their corresponding current values in the right column. You can edit parameter values using the stylus or keyboard arrows directly on the item field or from the menu.
3 KYMAN-NET™ Reader Parameters The barcode reading parameters and values are dependent upon the type of scanner module mounted in your mobile computer. For a detailed list of parameters and of their configuration procedures, please refer to the SDK Help file on the CD. Scan Parameters The Scan Parameters are common to all scanner modules and allow control of the scanning device.
USE AND FUNCTIONING 3 Default Settings The following tables contain the default values for the major barcode setup parameters, according to the type of scan engine mounted on the mobile computer. For a complete list of parameters and of their configuration procedures, please refer to the SDK Help file on the CD.
KYMAN-NET™ 3 BARCODE SYMBOLOGY SPECIFIC READER PARAMETERS MSI Plessey Code 93 Code 11 PDF - 417 Data Matrix QR POSTNET PLANET Japan Post Australia Post KIX Code Royal Mail Code (RM4SCC) * Laser Models (XXX-1XX, XXX-4XX) Enabled Disabled Disabled Disabled Imager Models (XXX-7XX) Disabled Enabled Enabled Enabled Enabled Disabled* These codes may be enabled individually but are disabled as a group. 3.6.2 Capture The Data Capture applet (Capture) enables code reading.
USE AND FUNCTIONING 3 Data Capture can also be enabled through the Configuration applet by selecting File ->Scanner from the main menu, or by enabling the parameter Scan Always On in the Scan Parameters branch. Enabling the Data Capture 3.7 CONTROL PANEL From the Desktop, double tap on the "Control Panel" icon to open the Windows CE .NET control panel main window. The Control Panel can also be launched from Start ->Settings ->Control Panel.
KYMAN-NET™ 3 3.7.1 Buttons The BUTTONS Applet allows assigning desired applications to be launched by one of the function keys (F1, F2, F3, F4). 3.7.2 Registry The REGISTRY ADMIN applet provides management of Windows CE .NET registry. Select the REGISTRY ADMIN applet by double tapping the Registry Admin icon. The Registry Administration Main window appears.
USE AND FUNCTIONING 3.7.3 3 Files Admin The FILES ADMIN applet enables control of the permanence of files in the System Folder. Two functions are available on the Files Admin Main window by means of two buttons: Files Admin Main Window Save Session: with this button all files will be permanently saved in the \Windows directory in non-volatile memory.
KYMAN-NET™ 3 Safe Setup First Mask Then select \Windows or a relevant sub-directory in the path box. Then, Safe Setup will recognize the new files and directories present in the \Windows directory, and will copy them to the \Backup\Windows directory. At the next hardware reset, these files will be restored (see par. 3.8.3). - Simply skip the first mask either by closing it or by pressing the ESC key.
USE AND FUNCTIONING 3.7.4 3 Wireless Communications The WIRELESS COMMUNICATIONS applet provides management of the Wi-Fi ® Card and of the Bluetooth and GSM/GPRS modules. Select the WIRELESS COMMUNICATIONS applet by double tapping the Wireless Communications icon. The following window will appear: Wireless Communications Window In order to avoid wasting power, all modules are off by default.
KYMAN-NET™ 3 3.7.5 Volume Settings The Volume Settings applet allows managing the audio features and appears as follows: Volume Settings Window The window is divided into three tabs: - Output tab: allows setting the volume for each audio profile; - Input tab: allows setting the microphone recording volume; Cradle tab: allows selecting the cradle type and managing the vehicle cradle headset functioning.
USE AND FUNCTIONING 3 Output Tab It allows setting the volume for each audio profile: The “Master Volume” slider allows setting the volume used by all audio profiles. In addition, it is possible to attenuate the volume for each single profile through the dedicated slider.
KYMAN-NET™ 3 Two radio buttons allow selecting the type of cradle to be used. Check the “Cradle desk, AC plug or none” radio button, if using a cradle different from the vehicle cradle or an AC adapter plug. If using a vehicle cradle, check the related radio button. NOTE By inserting the mobile computer into the cradle when the “Cradle vehicle” radio button is checked, the mobile computer speaker is deactivated and audio will be reproduced through the vehicle cradle speaker or headset.
USE AND FUNCTIONING 3.8 3 WINDOWS CONNECTIONS To connect Kyman-NET™ to another device (i.e. Host PC) from Windows, several programs are available in the "Connections" folder on the Kyman-NET™ Desktop. These programs require specific electrical connections in order to function properly. From the Desktop, double tap on the "Connections" folder to open the following window: Windows Connections 3.8.
KYMAN-NET™ 3 It is possible to constantly synchronize while connected to a desktop computer or, alternatively, synchronization can be performed only when the synchronize command is chosen. You can select which information types are synchronized and control how much data is synchronized. NOTE By default, ActiveSync® does not automatically synchronize all types of information. Use ActiveSync® options to turn synchronization on and off for specific information types.
USE AND FUNCTIONING 3.8.2 3 Bluetooth® Manager Device Setup In order to enable a Bluetooth® device for communication with the Kyman-NET™ you must perform the discovery procedure and enable the device as follows: 1. ® Place the Bluetooth device within the range of the Kyman-NET™ (10 meters). 2. From the “Connections” folder double tap on the “Bluetooth” applet to open the Bluetooth® Manager Device window: 3.
3 4. KYMAN-NET™ Tap on the “Discovery” button to enter the related window; then, tap on the “Scan” button to run the Discovery procedure. Once the Discovery procedure has been completed, select the desired Bluetooth® device from the list. It is also possible to digit ® (12 hexadecimal digits) the Bluetooth address of the desired device by tapping on the “Add” button. The “Clear” button deletes all discovered devices from the list. 5.
USE AND FUNCTIONING 3.8.3 3 FTP Server Setup The Kyman-NET™ Operating System includes a sample File Transfer Protocol (FTP) server. FTP is used for copying files to and from remote computer systems over a network using TCP/IP. You can establish a connection to your Kyman-NET™ using its FTP Server through the following interfaces: WLAN using the WiFi radio Proceed as follows: 1. Create a registry file (extension .reg) to setup and enable FTP Server communication.
KYMAN-NET™ 3 3.9 BACKUP DIRECTORY FILE MANAGEMENT All of the Windows CE .NET system files reside in RAM (volatile memory) except for the Backup directory, which resides in FLASH (non-volatile memory). Therefore the contents of the Backup directory are persistent even if the mobile computer is rebooted or the battery pack is changed. You can save your more important files that you don't want to lose due to mobile computer re-boot, in the Backup directory or create a sub-directory within Backup.
MAINTENANCE 4 4 MAINTENANCE Rechargeable battery packs are not initially charged. Therefore the first operation to perform is to charge them. See below. NOTE 4.1 CHARGING THE BATTERY PACK The battery pack autonomy varies according to factors, such as the frequency of barcode scanning, RF usage, etc. When the battery pack is low, the LED positioned at the right side of the display blinks orange.
KYMAN-NET™ 4 4.2 REPLACING THE BATTERY PACK To correctly replace the battery pack, proceed as follows. 1. Turn off the Kyman-NET™. 2. Pull the battery latch down as indicated in the figure below. 3. Remove the battery pack. Battery Contacts 4.
MAINTENANCE 5. 4 Press it back until the battery latch is automatically closed. WARNING NOTE 4.3 Do not incinerate, disassemble, short terminals or expose to high temperature. Risk of fire, explosion. Use specified charger only. Risk of explosion if the battery is replaced by an incorrect type. Dispose of the batteries as required by the relevant laws in force. In order to guarantee an adequate operating autonomy, when replacing the battery pack the mobile computer checks the battery energy level.
KYMAN-NET™ 5 5 TECHNICAL FEATURES 5.1 TECHNICAL DATA Kyman-NET™ Common Features Electrical Features Power DC supply Battery pack Internal backup battery 14 V ± 5% 2 cell Li-Ion 2200 mAh@ 7.4 V (nominal) Rechargeable Li-Ion 30 mAh Communication Features Serial interface Windows CE.NET COM Port RS232 USB 1.1 COM1 COM6 Wireless Features WLAN WPAN WWAN IEEE 802.11b DSSS Bluetooth® IEEE 802.15, Class 2, Version 1.
TECHNICAL FEATURES 5 Programming Features Operating system Windows CE .NET 4.
KYMAN-NET™ 5 Kyman-NET™ Imager Optical Features (XXX-7XX models) Imager Optical Features Max. resolution 1D Codes 2D Codes Skew angle Pitch angle Depth of field* 0.10 mm / 4 mils 0.17 mm / 6.6 mils ± 40 ° ± 35° 1D (linear): X-dimension mm (mils) Symbol size cm (in) 0.13 (5) 1.2 (0.47) 8.0 to 15.0 (3.15 to 5.90) 0.50 (20) 3.2 (1.26) 8.0 to 33.0 (3.15 to 12.99) 0.33 (13) 3.1 (1.22) 7.5 to 24.5 (2.95 to 9.
TECHNICAL FEATURES 5.2 5 READING DIAGRAMS Kyman-NET™ HP Laser (XXX-1XX models) Reading Zones (10° skew angle) 1.00 mm (40 mils) 300 0.50 mm (20 mils) 0.38 mm (15 mils) 200 0.25 mm (10 mils) 0.13 mm (5 mils) 100 0.19 mm (7.5 mils) 0 100 EAN 0.33 mm (13 mils) 200 300 mm 100 200 300 500 400 600 700 800 mm Kyman-NET™ RFID +Laser (XXX-4XX models) Reading Zones (10° skew angle) 300 1.00 mm (40 mils) 0.38 mm (15 mils) 200 0.19 mm (7.5 mils) 100 0.50 mm (20 mils) 0.25 mm (10 mils) 0.
KYMAN-NET™ 5 Kyman-NET™ XLR (XXX-6XX models) Reading Zones (10° skew angle) 0.
TEST CODES 6 6 TEST CODES High Density Codes 0.
KYMAN-NET™ 6 Medium Density Codes 0.
TEST CODES 6 Low Density Codes 0.
GLOSSARY Access Point A device that provides transparent access between Ethernet wired networks and IEEE 802.11 interoperable radio-equipped mobile units. Hand-held mobile computers, PDAs or other devices equipped with radio cards, communicate with wired networks using Access Points (AP). The mobile unit (mobile computer) may roam among the APs in the same subnet while maintaining a continuous, seamless connection to the wired network.
Flash Disk Non-volatile memory for storing application and configuration files. GPRS General Packet Radio Service. GPRS is a wireless packet-based communication service based on GSM. Its data transfer is rated between 56 Kbps to 114 Kbps. It makes very efficient use of available radio spectrum, and users pay only for the volume of data sent and received. GSM Global System for Mobile communication. It is a standard for digital cellular communications, currently used in the 900 MHz and 1800 MHz bands.
INDEX A Accessories; 5 Alphanumeric Keyboard; 18 Available Models; 2 B Backup Directory File Management; 44 Bluetooth® Approval; viii Bluetooth® Manager Device Setup; 41 Buttons; 32 C Charging the Batteries; 45 Cleaning the Mobile Computer; 47 Connection Cables; 11 RS232 Direct Connection; 11 RS232 Power Connection; 12 USB Direct Connection; 11 USB Power Connection; 12 Connections; 6 RS232/USB Direct Connection; 6 WLAN Connection; 7 WPAN Connections; 8 WWAN Connections; 9 Control Panel; 31 Conventions; vii
FCC Compliance; xiv Laser Safety; ix Radio Compliance; xiii SAR Compliance; xiv WEEE Compliance; xiv Save Session; 33 Scan Parameters; 28 Services and Support; vii SIM Card; 10 Startup; 13 Status Indicators; 24 T Test Codes; 53 U Using the Stylus; 14 V Vocal Communication; 36 Volume Settings; 36 W Wireless Communication; 35 Technical Features; 48 59
DATALOGIC S.p.A.
ETSI EN 300 328 v1.6.1, November 2004: ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); WIDEBAND TRANSMISSION SYSTEMS; DATA TRANSMISSION EQUIPMENT OPERATING IN THE 2,4 GHZ ISM BAND AND USING WIDE BAND MODULATION TECHNIQUES; HARMONIZED EN COVERING ESSENTIAL REQUIREMENTS UNDER ARTICLE 3.2 OF THE R&TTE DIRECTIVE ETSI EN 300 330-2 v1.1.