MagellanTM 800i On Counter Presentation Omnidirectional Bar Code Reader Quick Reference Guide
Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”).
DATALOGIC SCANNING, INC. MAGELLANTM END USER LICENSE AGREEMENT Notice to End User: The Datalogic Product you have acquired contains embedded Software, which is integral to the product's operation. This Software is being provided to you under license, subject to the terms and conditions of this Agreement. If you use the Datalogic Product, you will be deemed to have accepted the terms and conditions of this Agreement.
2.2 Agreement does not convey ownership of the Software to End User. Title to the Software shall be and remain with Datalogic or the third party from whom Datalogic has obtained a licensed right. As used in this Agreement, the term "purchase" or its equivalents when applied to the Software shall mean "acquire under license." End User is not entitled to receipt or use of the source code to any Software.
6.2 notice, Datalogic will use commercially reasonable efforts to remedy nonconformities verified by Datalogic. End User agrees to supply Datalogic with all reasonably requested information and assistance necessary to help Datalogic in remedying such nonconformities.
DAMAGES, EVEN IF DATALOGIC HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. 9. Government Restricted Rights; International Use. 9.1 9.2 Use, duplication, or disclosure of the Software by the U.S. Government is subject to the restrictions for computer software developed at private expense as set forth in the U.S. Federal Acquisition Regulations at FAR 52.227-14(g), or 52.227-19 or in the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013(c)(1)(ii), whichever is applicable.
Quick Reference Use the Quick Reference Guide (QRG) to find easy connection, scanning and troubleshooting instructions. For more details, including programming information, reference the Product Reference Guide (PRG), which is available for download, viewing and printing from the Datalogic website listed on the back cover of this manual. Installation Route the interface cable from the terminal or host.
The Magellan 800i utilizes illumix™ intelligent illumination technology to optimize light levels for a variety of bar code scanner functions including automatic reading of bar codes from printed surfaces, mobile devices and image capture in variable contrast environments. Mounting the Scanner (Optional) The scanner can be permanently attached to a wall or countertop as follows: 1.
Power Supply Models require1 an external Listed power supply marked Limited Power Source or LPS or class 2. For the safety certification to be valid, power supply must meet UL 60950-1/CAN/CSA-C22.2 No. 60950-1 or UL 1310/ CAN/CSA-C22.2 No. 223 for North America and IEC/EN 60950-1 for rest of world. Input: 100 - 240 VAC Max. Current: 2.5 A System Input Voltage Input: 5 VDC +/- 10% Output: 5 VDC Max. Power: 12.5 W Max. Power: 2.
Cell Phone Mode Cell phone mode is when the scanner is enabled to read barcodes on a cell phone display. To enable this feature, scan the START/END bar code, then scan the ENABLE AUTO CELL PHONE MODE bar code, then scan the START/END bar code a second time to exit Programming Mode.
Troubleshooting If the scanner is not operating properly, the following checks should be performed: 1. If the scanner uses an external power supply and the external power supply has failed, the scanner will not operate. Exchange the power supply with a known good power supply and retest operation. 2. Verify the interface cable is securely attached to the host. Consult your technical support personnel or refer to your host system manual to verify the proper connection for the scanner. 3.
Compliance Statement This device complies with Part 15 rules. Operation is subject to the following conditions: 1. This device may not cause harmful interference; and 2. This device must accept any interference received, including interference that may cause undesired operation. This Equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
FCC Caution Statement The user is cautioned that changes or modifications not expressly approved by the part responsible for compliance could void the user's authority to operate the equipment. This Class B digital apparatus complies with Canadian ICES -003. Cet appareil numérique de la classe B est confrome à la norme NMB-003 du Canada. Regulatory label located on bottom plate This illustration shows label placement ONLY.
DECLARATION OF CONFORMITY 11 EC-66 Rev.: 0 Pag.: 1 di 1 Datalogic Scanning, Inc. 959 Terry St.
Figure 1.
Australia Japan Datalogic Scanning Pty Ltd Telephone: [61] (2) 9870 3200 australia.scanning@datalogic.com Datalogic Scanning KK Telephone: 81 (0)3 3491 6761 japan.scanning@datalogic.com France and Benelux Latin America Datalogic Scanning SAS Telephone: [33].01.64.86.71.00 france.scanning@datalogic.com Datalogic Scanning, Inc Telephone: (305) 742-2206 latinamerica.scanning@datalogic.com Germany Singapore Datalogic Scanning GmbH Telephone: 49 (0) 61 51/93 58-0 germany.scanning@datalogic.