MagellanTM 8300/8400 Product Reference Guide Datalogic Scanning, Inc.
959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”).
Table of Contents Chapter 1. Introduction .................................................................................... 1-1 Manual Overview ..........................................................................................................1-1 How to Use This Manual ..........................................................................................1-2 Technical Support .........................................................................................................
Operational Verification .........................................................................................2-23 Diagnostic Modes ..................................................................................................2-26 Cables & Connections ............................................................................................2-27 Remote Scale Display Placement/Installation ..................................................................2-29 Lighting Considerations ................
Calibration Verification (Kilograms) ............................................................................... 5-11 Increasing-Load Test (Phase 1) .............................................................................. 5-11 Shift Test (Metric) ................................................................................................. 5-12 Increasing- Load Test (Phase 2) ............................................................................. 5-13 Blanking Test .......................
Number of Host Transmission Buffers ......................................................................6-76 AIM ID ................................................................................................................6-77 Label ID Control ...................................................................................................6-79 Global Prefix ........................................................................................................6-82 Global Suffix ...................
Keyboard Wedge/USB Keyboard Features .................................................................... 6-144 Keyboard Interface — Keyboard Layout ................................................................. 6-144 Keyboard Interface Quiet Interval ......................................................................... 6-153 Keyboard Interface Caps Lock State ...................................................................... 6-154 Keyboard Interface — Keyboard Simulation ........................
EAN-8 Minimum Segment Length .......................................................................... 6-211 Other UPC/EAN Options ............................................................................................. 6-217 Price Weight Check ............................................................................................. 6-218 In-Store Label Minimum Reads ............................................................................. 6-221 Enable EAN Two Label ...........................
Code 128 Transmit Function Characters ................................................................. 6-286 Convert Code 128 to Code 39 ............................................................................... 6-287 Code 128 Label ID .............................................................................................. 6-288 Code 128 Length Control ..................................................................................... 6-289 Code 128 Length 1 ...................................
Code 93 Minimum Reads ..................................................................................... 6-343 MSI/Plessey Enable ................................................................................................... 6-345 MSI/Plessey Check Character Calculation ............................................................... 6-346 MSI/Plessey Number of Check Characters .............................................................. 6-347 MSI/Plessey Check Character Transmission ..............
Datalogic Handheld Data Format Requirements ......................................................... G-2 AIM Formats .......................................................................................................
NOTES x MagellanTM 8300/8400
DATALOGIC SCANNING, INC. MAGELLANTM END USER LICENSE AGREEMENT Notice to End User: The Datalogic Product you have acquired contains embedded Software, which is integral to the product's operation. This Software is being provided to you under license, subject to the terms and conditions of this Agreement. If you use the Datalogic Product, you will be deemed to have accepted the terms and conditions of this Agreement.
6.2 ing to Datalogic's standard assistance practices. Datalogic does not warrant that the product will meet End User's requirements or that use of the product will be uninterrupted or error free, or that Datalogic's remedial efforts will correct any nonconformance.
Chapter 1 Introduction This Product Reference Guide contains comprehensive instructions on scanner or scanner/scale installation. Either model may be termed “scanner” for the purpose of simplicity in this manual. Also included are feature configuration using special programming feature bar code labels and advanced user information as described in the following chapter descriptions.
Chapter 6, Programming, highlights the function(s) of each programmable feature and provides a dedicated set of bar codes for configuring scanner and scanner/scale features. This chapter is organized by the categories: General Features, Interface Related Features and Symbology Related Features. Appendix A, LED/Beeper Indications & Controls, contains tables describ- ing the various functions and indications of the scanner/scale control panel features.
Manual Overview Manual Conventions ‘NOTE’ blocks contain information that is helpful and recommended. They provide information that is critical to operations and/or procedures described in this manual. LEGAL NOTE ‘LEGAL NOTE’ blocks indicate procedures or activities which may be regulated under law by governmental agencies. It is your responsibility to ensure compliance with the regulations that govern installation of weighing devices.
Technical Support Datalogic Website Support The Datalogic website (www.scanning.datalogic.com) is the complete source for technical support and information for Datalogic products. The site offers the Datalogic TekForum, product support, product registration, warranty information, product manuals, product tech notes, software updates, demos, and instructions for returning products for repair.
Scanner and Scanner/Scale Nomenclature Scanner and Scanner/Scale Nomenclature Controls, indicators and other nomenclature are shown in Figure 1-1. Figure 1-1.
Connections Two connector panels are located on either side of the scanner as shown in Figure 1-2. The appearance of these panels will vary depending upon the factory options purchased with your model. Additionally, a service “pigtail” extends from the scanner’s base to connect the control panel cable from the Bonnet area. Figure 1-2. Connectors Control Panel Service Loop Scanner Right Profile Scanner Left Profile 0.00 EAS Port EAS PORT Aux.
Physical Parameters Physical Parameters This chapter provides specifications for performance, environmental and electrical parameters. Reference Chapter 2, Site Preparation and Installation, for physical measurements of all models and some accessories. Scanning The scanner has a scan zone between the two windows where the scanner projects laser light in order to scan items.
Weighing Specifications for scale capacity, settling time, minimum and maximum static weight, zeroing, and warm-up time are given below. For more information regarding the topic: Proper Weighing Technique, refer to Chapter 3, Operation and Maintenance in this manual. Rated Weight Capacity The scale’s operational weight capacity is: • 30.00 pounds, displayed in 0.01 increments OR • 15.000 kilograms, displayed in 0.005 increments.
Physical Parameters Warm-Up Time There are two pertinent warm-up times that apply to the scanner or scanner/scale: The two warm-up periods can be performed concurrently, thereby reducing the total required warm-up time to 60 minutes. NOTE Thermal Equilibrium When the unit is moved from a cooler temperature (such as a storage area) to a warmer environment (such as a checkstand location), 60 minutes must be allowed to acclimate the unit to ambient conditions prior to calibration or operation.
Figure 1-3.
Electrical Specifications Power Supply Power Off the Terminal (P.O.T) Certain units can receive power directly from the terminal (P.O.T.). A USB adapter “brick” connects the scanner to IBM-USB 12V ports. Power supplied from the terminal does not include auxiliary power for alternative scales. NOTE AC Adapter Units which do not receive power directly from the terminal will use either a Listed Class 2 or Listed LPS power source which supplies power directly to the unit.
Laser and Product Safety Laser safety requirements are based on IEC Standard Publication 60825-1 (2007) and CDRH 21CFR, Chapter 1, Subchapter J and (CDRH) Laser Product Performance Standard, User information [1040.10(h)1]: • User Maintenance. No user maintenance of the laser system other than cleaning of the scan windows is required. • Radiant Energy. The scanner is an IEC Class 1 and CDRH IIa laser product. The system uses two embedded Class 3A Visible Laser Diodes (VLDs) operating at 650.
Laser and Product Safety Safety precautions to be taken: No adjustments or alteration of the scanner or scanner/scale housing are to be attempted by the user. CAUTION WARNING The failure of the facet wheel motor while the unit is continuing to emit a laser beam causes the emission levels to exceed those for inherently safe operation. The unit has safeguards to prevent this occurrence.
Labeling Regulatory, reference and safety labeling is shown in Figure 1-4. Figure 1-4.
Agency Compliances Agency Compliances The scanner and scanner/scale meets or exceeds the requirements for its device type as set forth by the following agencies and regulations: COUNTRY COMPLIANCE COMMENTS Electrical United States UL 60950 State of California Energy Efficiency Standard Canada CAN/CSA 60950 Europe TÜV EN 60950 Mexico NOM Korea K-Mark Argentina IRAM Taiwan BSMI China CCC Japan PSE Australia/New Zealand AS/NZ 60950 Emisions United States 47CFR Part 15J FCC Class B
COUNTRY ROW COMPLIANCE CISPR 22 COMMENTS Class B Laser Safety United States CDRH, 21CFR Part 1040 CDRH Class IIa laser device Europe IEC 60825-1:2007 EN 60825-1:2007 Class 1 Class 1 Weights & Measures United States NIST Handbook 44 Canada Measurement Canada (Dept.
Bar Codes Supported Bar Codes Supported The scanner can read/decode the following bar code types (symbologies): Retail Codes • UPC Versions A & E with full expansion E to A, plus A and E to 13 capability • UPC Supplementals and Add-ons (Bookland & Coupon code, UPC two character supplemental encodation and UPC five character supplemental encodation and supplemental C128) with support for conditional add-ons • DataBar Omnidirectional (formerly RSS-14) • DataBar Expanded (formerly RSS Expanded) maximu
Dual Bar Codes for Japan (2 label read) NOTE 1-18 The following qualifications apply to Dual Bar Codes for Japan: • Two label combined transmission • Two label global midamble (see Chapter 6, Programming, for more details) • Two label flag is set by selecting any 4 digits as the flag MagellanTM 8300/8400
Chapter 2 Site Preparation and Installation This chapter provides a reference for preparing most checkstands to receive the scanner or scanner/scale. Included are physical parameters and instructions for checkstand preparation, power and ventilation considerations, cable routing information and unit installation. Site Preparation lists all procedures necessary to prepare the checkstand.
Models Scanner and scanner/scale models (reference Figure 2-1) are available in different lengths, allowing them to fit with little or no modification into openings cut for previously installed scanners such as Datalogic® Magellan® scanners, or NCR® scanner models 7820/24 and 7870. Other models are designed for applications with smaller footprint requirements. Figure 2-1 provides simplified illustrations of short, medium and long models. The appearance of your unit may vary.
Pre-Installation Considerations Figure 2-3. Produce Bar and Produce Rail Produce Bar Option Produce Rail Option Pre-Installation Considerations It should be noted that the scope of this manual does not encompass all factors related to worker safety and checkstand design. It does, however, offer a list of considerations that may be helpful in ensuring greater safety and productivity. Careful planning using these general guidelines should result in a more efficient, comfortable work environment. The U.S.
Checkstand Design 1. Select a design which allows load-sharing by several muscle groups (for example designs which allow the cashier to use both hands for scanning and bagging). 2. Select checkstands which deliver products to the cashier on an input belt and do not require the unloading of items from a cart. These designs put less stress on the cashiers’ shoulders and back. 3. Minimize the distance between the input and take-away conveyors (i.e., the distance the cashier has to reach to move the products).
Scanner Installation Scanner Installation 1. Mount the horizontal surface of the scanner flush with the countertop to encourage slide scanning rather than lifting. 2. Position the centerline of the scanner read area 8 - 10 inches (20.3 25.4 cm) from the edge of the checkstand (cashier side). Scanner Maintenance 1. Keep scanner windows clean. This will improve productivity and reduce rescans. 2. Replace scanner glass when excessive scratches are evident.
• Develop a smooth fluid motion during scanning, sharing work equally between hands. • Use the entire hand for grasping and lifting items. • Since the scanner reads labels on all four sides plus the top and bottom, there is no need to turn a bar code toward either of the scanner windows. • Develop efficient scanning motions, not necessarily faster hand movements. Simply slide the item across the scanner’s horizontal window with as little orientation motion as necessary.
Site Preparation Overview Recommended Power Installation — Since the typical grocery envi- ronment includes conveyor belts and electric motors, care should be taken to ensure that the scanner has a supply of “clean” power (power without excessive electrical noise). A wiring diagram shows the recommended wiring that will provide the scanner with a “clean” source of power. Refer to Figure 2-6.
unavoidable, an alternate method of platter removal using two coins may be employed, however a minimum vertical clearance of 1.5” (3.8 cm) MUST be provided (reference Figure 2-4). Another consideration is that the scan zone must be kept free of obstructions such as enclosures, keyboard mounts, etc. Figure 2-4. Vertical Clearance DO NOT Obstruct L-Platter Removal (Keyboard Mount) DO NOT Obstruct Scan Zone Allow a minimum clearance of 1.5" (3.
Ventilation and Spacing • A source of air that provides adequate cooling by convective air flow. DO NOT place the scanner in a close-fitting, fully enclosed checkstand. Provide a MINIMUM of 16 square inches (103.2 square centimeters) of air intake from below the installation for sufficient convective cooling. NOTE If motors, conveyor belts, or other heat producing equipment are located near the scanner, forced air ventilation may be required. In most installations, a 30 cfm (.
Service Access The scanner and scanner/scale have been engineered to allow performance of all routine service and maintenance (such as “zeroing” and calibration) without removing the scanner from the checkstand. Additionally all cable connections made at the scanner can be connected and removed while the unit is sitting on the countertop. The installer should provide service access to all remaining cable connectors as well as the AC/DC Power Supply (if installed).
Power Installation Power Installation Reference the wiring diagram in Figure 2-6 for the recommended fusing arrangement. Grounding The AC/DC Power Supply should have an AC outlet with a clean earth ground. If you are not sure how to verify the amount of electrical noise (interference) on the power line, ask a qualified electrician to measure the input line voltage. Figure 2-6.
Checkstand Preparation Reference Figure 2-7. When performing a first time installation into a new checkstand, verify before cutting that room will be allowed for cabling, the AC/DC Power Supply, and any EAS peripheral equipment (such as controller boxes, etc.). When making the opening, take extra care to accurately cut to the correct dimensions. Mounting may require installation of support(s), countertop routing, or other such devices.
Counter Cutout Liquid Spills and Moisture Select a checkstand design which allows fluids to flow through, and directs liquids away from any electronic equipment or storage areas. Counter Cutout The most important consideration when planning the counter opening for the scanner is the operator’s comfortable reaching distance. The ideal, ergonomically sound installation allows items to be directed within easy reach, and a scanning area requiring no lifting or special orientation of items.
3. Install the AC/DC Power Supply, the Remote Scale Display cable (if Remote Display is used) and the interface cable(s) observing the following: Interface cables (and display cable, if applicable) should be routed away from all highly inductive electrical devices, like motors and conveyor belts, and even away from the unit’s power cable if possible. Cables should be easy to remove in the event that replacement is required. A little planning now will save a lot of frustration later. 4.
Counter Cutout Figure 2-8. Typical Checkstand Design & Cutout Location Remote Display Conveyor POS Terminal & Printer Optional Item Diverter Deadplate 6.3" (16.
Figure 2-9. Short Shelf Model 8301/8401 Cutout Dimensions Model 8301/8401 (Short) Minimum Cutout Dimensions Model 8301/8401 (Short) Supports Max. Radius = 0.25" (0.635cm) 4x 14.00" (35.6cm) min. 11.625" (29.53cm) min. 4.08" (10.36cm) Liquid Drainage Liquid Drainage Support Rails Figure 2-10. Short Shelf Model 8301/8401 Scanner Reference Dimensions Model 8301/8401 (Short) Scanner Reference Dimensions 11.5" (29.21cm ± 0.1cm) 4.59" (11.7cm) 5.19" (13.2cm) 5.6" (14.22cm) 9.27" (23.6cm ± 0.2cm) 4.
Counter Cutout Figure 2-11. Medium Shelf Models 8302/8304/8402/8404 Cutout Dimensions Models 8302/8304/8402/8404 (Medium Shelf) Minimum Cutout Dimensions Max. Radius = 0.25" (0.635cm) Optional Leveling Feet 4x 15.825" (40.2cm) min. 11.625" (29.53cm) min. 1.76" (4.47cm) Leveling Feet 6.89" (17.5cm) Models 8302/8304/8402/8404 (Medium Shelf) Supports 4.08" (103.6mm) Shelf/ Support Rails 10.83" (27.5cm) Liquid Drainage Liquid Drainage Support Rails Figure 2-12.
Figure 2-13. Medium Flanged Models 8302/8304/8402/8404 Cutout Dimensions Models 8302/8304/8402/8404 (Medium Flanged) Minimum Cutout Dimensions 18.00" (45.7cm) 16.625" (42.23cm) Max. Radius = 0.25" (0.635cm) 4x Rail 3.06" (7.77cm) 0.75" (1.905cm) 11.625" (29.53cm) (Center Line) Rail 3.06" (7.77cm) 0.75" (1.905cm) If leveling feet are needed, use the placement shown here, represented with plus signs (+). 0.375" (0.952cm) 0.375" (0.952cm) Models 8302/8304/8402/8404 (Medium Flanged) Supports 18.
Counter Cutout Figure 2-15. Long Shelf Models 8303/8305/8403/8405 Cutout Dimensions Models 8303/8305/8403/8405 (Long Shelf) Cutout Optional Leveling Feet Max. Radius = 0.25" (0.635cm) 4x 17.87" (45.4cm) 11.625" (29.53cm) 1.76" (4.47cm) Leveling Feet 6.89" (17.5cm) Models 8303/8305/8403/8405 (Long Shelf) Supports 4.08" (10.36cm) Shelf/ Support Rails 10.83" (27.5cm) Liquid Drainage Liquid Drainage Support Rails Figure 2-16.
Figure 2-17. Long Flanged Models 8303/8305/8403/8405 Cutout Dimensions Model 8303/8305/8403/8405 (Long Flanged) Cutout 20.00" (50.8cm) 18.625" (47.308cm) Max. Radius = 0.25" (0.635cm) 4x Rail 3.06" (7.77cm) 0.75" (1.905cm) 11.625" (29.53cm) (Center Line) Rail If leveling feet are needed, use the placement shown here, represented with plus signs (+). 3.06" (7.77cm) 0.75" (1.905cm) 0.375" (0.952cm) 0.375" (0.952) Model 8303/8305/8403/8405 Supports 20.00" (50.8cm) 0.75" (1.9 cm) 1.5" (3.8 cm) 0.
Installation Overview Checkstand Mounting There are a number of things to take into account when installing the unit into a checkstand. Key factors are ergonomic/worker safety, loading capacity and stability. Consider the scanner or scanner/scale’s weight when calculating the robustness of construction needed to support it as well as maximum capacity of weighed and scanned items. NOTE If you choose to rout a countertop with a thickness of 0.75” (1.
6. Functional testing to verify operation when connected to the POS system. The following text describes each of these steps. Unpacking To unpack the unit: • Inspect the package for signs of damage that may have occurred during shipping. If damage is found, report it to your carrier immediately. • Lift out the accessory box containing the AC/DC Power Supply, optional Remote Scale Display and cable (if present), and the Quick Reference Guide.
Installation Overview Figure 2-19. Remove Protective Vinyl Protective vinyl MUST be removed from the platter before use. • Proceed to the Operational Verification instructions below. Operational Verification Follow these steps to ensure that your unit has arrived undamaged and is fully functional before installing it in the counter and connecting it to your POS system. 1. EAS units ONLY: It could be necessary that EAS connections be made previous to power-up.
When power is applied to the unit, the normal indicator sequence is: • The scanner indicator (top-most, green LED) will be lit (dim) steadily. • The 7-segment display will flash the number ‘8’. indicating initialization. • If the Selftest detects a problem, the 7-segment display will display a number code. Refer to Chapter 4, Problem Isolation, for a description of failure codes and problem isolation procedures.
Installation Overview Scanner — Pass UPC/EAN bar code labels in front of the scanner’s win- dows. Since the interface cable is not yet connected to the POS terminal, the scanner may be limited to reading only one or two labels (see the note that follows). The scanner indicates when each label has been successfully read by flashing the green scanner light and emitting a good read tone (beep). Some host interface types may “chirp” instead of beeping.
Diagnostic Modes Two diagnostic modes are available which allow you to initiate scanner or scale diagnostic tests, as well as verify the scanner’s ability to read bar codes. Scanner Diagnostic Mode While in Scanner Diagnostic Mode, continuous scanning of labels is allowed, permitting the user to scan an unlimited number of bar codes while troubleshooting problems. Under normal operation, the scanner stores label data, awaiting the signal which transmits it to the host.
Installation Overview Scale Diagnostic Mode To enter Scale Diagnostic Mode, press the Scale Zero Push Button for approximately four seconds. Six rapid tones will be sounded, indicating the unit is leaving normal operation and entering Scale Diagnostic Mode. The Remote Display will flash a ‘1’ across the display while the dignostic routine is being run. When diagnostics are completed successfully, the display will indicate that the unit has passed the diagnostic test by displaying PASS .
Figure 2-20.
Remote Scale Display Placement/Installation Figure 2-21 provides physical dimensions for the AC/DC Adapter (part number 8-0582). Figure 2-21. Physical Measurements: AC/DC Adapter 1.23" (3.1 cm) 1.97" (5 cm) 5" 3.3 m) c (8.5 Remote Scale Display Placement/Installation The modular Remote Display is designed so that single display heads can be stacked to form a dual display as shown in Figure 2-22a in order to address the specific viewing needs of both the customer and the cashier.
Viewing Angle The optimum display angle is directly facing the viewer. Tilt and rotatioin adjustments can be made as shown in Figure 2-22b. To ensure that displays are easily readable for customers/cashiers of average height, display heads should be between 48” to 60” (122 to 152 cm) from the floor. Check with local Weights and Measures authorities regarding proper positioning of scale displays used in retail trade. NOTE Figure 2-22.
Remote Scale Display Placement/Installation Remote Display Cabling Your installation should also take into account the routing of Remote Display cabling. Ensure that distance and obstacles spanned by the routed cable will not kink, pinch or stretch it. Also keep in mind you may need to drill a hole through which to route it. NOTE The Remote Scale Display connector end may be secured with a rubber band during shipping to prevent damage to the “locking tabs” (see Figure 2-24).
Figure 2-23. Physical Measurements: Remote Display 18.5mm Dual Display Single Display 28.4mm 60mm 60mm 112mm 112mm 329mm 264mm 292.5mm 325mm 227.5mm 116.39mm 116.39mm 25.5mm 41.99mm 85.1mm 5. Feed the entire length of the Remote Scale Display interface cable through the cable routing hole so that the assembled Remote Scale Display can be positioned over the mounting screw holes. 6. If present, remove the rubber band from the connector end. 7.
Remote Scale Display Placement/Installation Figure 2-24. Remote Scale Display Mounting 36" (91cm) 48 - 60" (122 - 152cm) 24" (61cm) Dual Display Heads 11.5" (29cm) Mounting Example Single Display Head (optional cable routing) Figure 2-25. Remote Scale Display Mounting Template 116.39mm 41.99mm 85.1mm Product Reference Guide 25.
Changing Weighing Modes Your scanner/scale has been programmed for weighing in either pounds or kilograms depending upon the initial operating environment that was specified when you ordered your scanner/scale. If you need to change from pounds to kilograms or vice-versa, call technical support. You can verify that the scale is set correctly for your country’s requirements by observing that the Remote Scale Display shows the appropriate measurement symbol (lb or kg) when the power-up Selftest is completed.
Set-Up & Installation If you have a scanner with no scale, there will be only one interface cable to the POS terminal. 4. Connect the power cord to the scanner and route the other end down through the checkstand to the AC power outlet. DO NOT plug the power cord in at this time. Figure 2-26. Connecting Cables to the Scanner/Scale Control Panel Service Loop Scanner Right Profile Scanner Left Profile 0.00 EAS Port EAS PORT Aux.
Installation 1. Make sure that all cables are firmly attached (except that the AC/ DC power supply should not be connected to the AC outlet yet). Reference Figure 2-7 and Figure 2-26. 2. Remove the platter to gain access to the interior lift handle. Grasp the platter in the positions shown in Figure 2-27 and gently lift it from the scanner. If the top edge of the platter is blocked, you may find it easier to grasp the platter vertical bezel as shown in Figure 227b.
Set-Up & Installation 3. Rotate the Interior Lift Handle up as shown in Figure 2-28 and hook the fingers of both hands in the lift handles indicated. DO NOT attempt to lift the unit using the plastic edges, scale frame, or any features other than the lift handles. 4. Lower the unit into the counter opening, ensuring that none of the cables are pinched, pierced or crimped. 5. Re-install the Platter and verify that it is flush or just below flush with the countertop.
Adaptive Scale Platter Option Some Platters have been shipped with installed spacers on their undersides at all four corners. These specially-configured Platters are provided for customers wishing to add an adaptive scale to their unit at a later date. Until such time as the adaptive scale is installed, the four spacers should be left in place to ensure that the Platter rests evenly at its correct height when positioned on the scanner.
System Power-Up Recap System Power-Up Recap The System Power-Up procedure may vary depending upon the requirements of your POS system. It is generally a good practice to power-down (switch off ) all equipment prior to connecting cables. Check with your System Supervisor and/or refer to your POS terminal manual for proper power-down and power-up procedures and interface requirements when connecting any peripheral device.
6. Power-up the scanner or scanner/scale by connecting the power cord to an AC power outlet. Wait for the unit to complete the Self test routine (10 seconds maximum). Successful scanner power-up is signified by any or all of the following: - Facet wheel shows movement - Lasers turn on - Status LED(s) turn on - Speaker sounds tone(s) - Remote display [if present] shows message - A single red dot is visible on the 7-segment display 7. Power-up the POS terminal.
Chapter 3 Operation and Maintenance The information contained in this chapter describes how to operate and maintain the scanner, and optional scale and EAS systems. Topics include “how to’s” on scanning, EAS label deactivation, weighing, re-zeroing the scale, removing the top cover and cleaning the upper and lower windows. Scanning Items To scan items using the scanner, slide or push them through the scan zone as shown in Figure 3-1.
Figure 3-1. Scan Zone Note that eyes... ...indicate what the scanner "sees." Vertical Window Scan Zone Horizontal Window Scan Zone Checker Side Scan Zone Proper Scanning Technique The scanner was designed to provide the ultimate in ergonomic enhancements for Point-Of-Sale (POS) scanning. To take advantage of these advancements: Practice the techniques below to improve scanning efficiency: 3-2 • Move the product across the horizontal window (See Figure 3-1).
• Develop efficient scanning motions, not necessarily faster hand movements. • Learn typical locations for bar codes on packages; avoid “flipping” or rotating the items during scanning. • Learn how the scanner functions and where the scanning area is located. Deactivating Security Labels EAS (Electronic Article Surveillance) labels can be detected and deactivated by a system equipped with this option. This is accomplished by means of a deactivation antenna mounted under the scanner platter.
Proper Weighing Technique 1. The L-shaped All-Weighs™ platter allows you to place items anywhere on its surface, including leaning against its vertical section, to be weighed accurately. The “Produce Rail” or (when raised) the “Produce Bar” also provide a convenient way to ensure items do not rest on the counter or other non-weighing surfaces. (Reference Figure 3-2.) It is important that items rest entirely on the platter for their full weight to be accurately recorded. NOTE Figure 3-2.
Operational Controls Operational Controls The function of scanner and scale controls and indicators is listed in Appendix A, LED/Beeper Indications & Controls. Turn to that appendix for full details. Operational Modes The scanner or scanner/scale features a number of modes that are important to both the user and the system support personnel. These modes can be combined into three groups: pre-operational, operational, and additional functions.
Error Reporting If a fatal error is detected during Selftest or operation, the unit will not advance to Normal Operation Mode. Selftest diagnostics will cause the unit to sound a long, low tone and/or display an error message on the 7segment display indicating where the failure occurred. These messages are coded to assist the repair technician in identifying the failed component. If an error is indicated, make note of it and contact your supervisor or technical support representative.
Operational Modes • When the scanner or scanner/scale completes its Selftest successfully, it emits a tone (when configured to do so) and enters Operating Mode. Operating Mode Operating Mode includes Normal Operation (scanning, EAS deactivation and weighing) and Sleep Mode. These two modes are most commonly observed by the user/operator. Normal Operation This condition is indicated by the scanner green LED being on dim and steady.
Sleep Mode After the scanner has been left idle for a preset period of time, the laser and/or motor automatically turns off (goes to sleep). This state is called Sleep Mode, and is indicated by a “slow” blink of the green light (blinking at a 2-second rate). To wake up the unit, press anywhere on the weigh platter (scanner/scale models only), press the Volume Selection switch or wave your hand over the horizontal window.
Additional Functions Scanner and Scale Reset The reset procedures and indicators are identical for scanner and scanner/ scale models. As with any electronic equipment, it is sometimes necessary to reset the electronics. The reset procedure allows you to initiate a reset command to the scanner. This may be necessary if the POS terminal has been switched off or the store system has been reset while the unit is on. Reset can also be used to initiate and run the unit’s internal Selftest routine.
With the scanner/scale powered-up and at operating temperature: 1. Remove everything from the weighing surface of the scanner/scale. 2. Press the Scale Zero Push Button. (See Figure 1-1). 3. The Zero1 light will turn on and the display will show 0.00 lb (0.000 kg). If it does not, see Chapter 4, Problem Isolation. 4. You have completed the scale zeroing function.
Operational Maintenance Operational Maintenance The scanner or scanner/scale will provide dependable service for many years. The following maintenance procedures will keep your scanner or scanner/scale operating at peak performance. Cleaning the Platter and Scan Windows. Clean the exterior surfaces of the horizontal and vertical scan windows at least twice daily with a nonabrasive, mild, water-based glass cleaner and paper towels or lint-free cleaning tissues.
Vertical Scan Window Replacement The Vertical Scan Window is a replaceable part. Follow the instructions below to remove and replace a standard or L-Platter Vertical Scan Window. Standard Vertical Scan Window Removal 1. Lift up on the vertical bezel as shown in Figure 3-3a and tilt its top up and away from the scanner as shown in Figure 3-3b. Figure 3-3. Removing/Reinstalling the Vertical Bezel a b Retention Tabs c d 2.
Operational Maintenance 4. Fully seat the new Vertical Scan Window into the window channel, engaging it within the retention tabs. Reference Figure 3-3d and Figure 3-3c. 5. Clean both sides of the new Vertical Scan Window using a paper towel or lint free cleaning tissues dampened with a mild, waterbased glass cleaner. DO NOT use abrasive cleaners or pads. 6.
2. If the top edge of the platter is blocked, you may find it easier to use a coin to lift up an edge of the platter as shown in Figure 3-4b, then grasp the platter vertical bezel or other exposed edge. NOTE Use caution to avoid damage to the now exposed horizontal and Vertical Scan Windows.
Operational Maintenance Horizontal Scan Window Replacement (WRG) Wear Resistant Glass (WRG) horizontal scan windows are replaceable and can be removed and replaced following the instructions below. Sapphire glass does not require replacement, so it is permanently fastened in place. Do not attempt to remove Sapphire glass from the platter. NOTE 1. Remove the Platter from the scanner as shown in Figure 3-4. 2.
Figure 3-6.
Chapter 4 Problem Isolation In the event of a suspected functional problem, use the troubleshooting references provided in this chapter. This useful information will help you to identify and resolve the cause of the problem. The scanner/scale has a number of features that indicate when a scanner or scale problem occurs.
Operational Tests These are the tests that run continually during Normal Operation and Sleep Mode. Firmware checks all subsystems, accessory connections and the POS interface to verify everything is operating normally. If a problem is detected at any time, a long, low tone is sounded, an error code is shown on the 7-segment display, and operation may be halted. If you press the Volume/Tone Push Button at that time, a series of tones will be sounded that matches the error code displayed.
Error Codes Error Codes If an error is detected, the scanner will sound a long low tone (for one second) and alternately flash its LEDs, indicating a failure. Following the long low tone, an error code will appear on the 7-segment display (refer to Figure 4-1). Pressing the Volume/Tone Push button will cause the scanner to sound a series of beeps corresponding to that error code. Table 4-1 on the following page describes what these codes mean and what action should be taken for each.
Table 4-1. Error Codes Error Code Probable Cause Corrective Action Configuration No POS interface has been selected (Null interface). See Chapter 6, Interface Type to select the required interface using programming bar codes. 1 Configuration Error See Chapter 6, Programming, for details about configuring the scanner using programming bar codes. 2 Interface Board Unplug unit and call technical support personnel. 3 Motor Unplug unit and call technical support personnel.
Error Codes Figure 4-1.
Scale Error Reporting Scale diagnostics uses the Remote Scale Display and the Zero Status lamp to communicate specific scale failures. The following chart shows the Remote Display messages, the Scale Status lamp indication, the problem that the scale is experiencing and what action should be taken. When troubleshooting, always remember to check all cable connections first before proceeding with other problem isolation steps.
Flowcharts Remote Display -0- Scale Status Lamp Problem Description Cannot zero at power- up or weight remains on scale for more than 2 minutes or weight has not returned to zero between POS weight requestsa. Off Action Required - Check debris chutes. - Verify that the weigh platter moves freely. - Remove item(s) from scale - Press Scale Zero Push Button - for more information. - If the scale still fails to zero, recalibrate the scale. a. This is a configurable feature.
Figure 4-2. Problem Isolation: Start For units using an AC/DC adapter, verify that... 1. AC power cord is connected to a functional AC outlet. 2. IEC connectors are firmly connected. 3. DC power cord is firmly connected to scanner. If your unit is a model which receives Power Off the Terminal POT), verify that the I/F cable is securely connected at both ends.
Flowcharts Figure 4-3. Problem Isolation: Selftest SELFTEST START Does the 7-segment display show 0 ? Does the 7-segment display show 1. ? NO Scan the Factory YES Defaults bar code in Section 6 to enable the default configuration file. Restart the unit. NO YES No interface selected (Null Interface). Select an interface. Go to EAS System flowchart YES Does the 7-segment display show 9. ? NO Does the 7-segment display show 2. or 3. ? NO YES Does the 7-segment display show 4. or 5.
Figure 4-4. Problem Isolation: Poor/No Reading Have you verified that all scan windows are clean and scratch-free? POOR/NO READING START Enter Scanner Diagnostic Mode by holding the Volume/Tone Push Button for 4 seconds (until first 3, and then 6 rapid tones are sounded) then release. Scan a known-good bar code. A good read is signified by one flash of the Green LED and a single beep1.
Flowcharts Figure 4-5. Problem Isolation: No Transmit to POS NO TRANSMIT TO POS START Check the interface (I/F) cable connections. If possible, retest the system using a knowngood I/F cable. Does the scanner pass the data to the POS ? YES NO Verify programmable parameters using the information and programming bar codes provided in Section 6. Check interface and I/F options, inactive symbologies and other configurable features.
Figure 4-6. Problem Isolation: Scale SCALE START View the Remote Display and/or the Yellow scale status LED for the scale error code. Reference the topic, Scale Error Reporting in Section 4 for more information. If this is a new installation, make sure any foam packing pieces have been removed from the scale cavity before proceeding. Lift off the platter to verify, then set the platter back into position. NO -0shown on YES - Check for debris under platter.
Flowcharts Figure 4-7. Problem Isolation: Remote Display REMOTE DISPLAY START Is the unit configured for a Remote Display ? NO Scanner-scale models that include a Remote Display when shipped from the factory, are configured for use with the display. If you're unsure of the settings for your unit, contact Tech Support. Use the programming bar codes in Section 6 to enable operation using a Remote Display.
Figure 4-8. Problem Isolation: EAS System NO EAS DEACTIVATION START Verify programmable parameters using the information and programming bar codes provided in Section 6. Check EAS options, and other configurable features. Check all EAS cable connections. Does the EAS Antenna deactivate labels ? YES DONE Before proceeding, verify the EAS Antenna and associated equipment have been correctly installed (ref. Chapter 2). Ensure operator has been trained in proper EAS system use (ref. Chapter 3).
Chapter 5 Calibration A number of situations require the scale to be calibrated. They are: • at initial installation of the scanner/scale • if the scale cannot be re-zeroed • if you change the weight measure from pounds to kilograms or viceversa • if diagnostics indicate a calibration error • the weigh module has been replaced Follow the procedures on the following pages to ensure that the scanner/ scale will meet Weights and Measurement requirements.
Description of Calibration Sequence The Calibration Sequence sets the scale to an accurate reference point for weighing. This process involves the use of a Field Standard Weight Set (31.5-pounds) for calibration in pounds, (18.5-kilograms) for Metric. Once calibration has been successfully completed, the scanner/scale uses the certified weight as a reference for subsequent weighing activities. These verification procedures follow the U.S.
Motion Test • Lead/Wire or Paper Seal (as required by law). Motion Test This test verifies that the scale will not ‘zero’ when the weighing surface of the scanner/scale is in motion. 1. Verify that the Yellow LED1 is on and the Remote Display reads 0.00 pounds or 0.000 kilograms. 2. Press lightly on the weigh platter of the scanner/scale with one hand and at the same time press and release the Zero Push Button on the operator’s panel.
Preparing the Scanner/Scale for Calibration 1. Assure that the scanner/scale is stable, secure and properly installed. (Refer to Chapter 2, Site Preparation and Installation, for instructions on the proper installation of the scanner/scale). 2. Power-up the scanner/scale. 3. Allow the unit to reach temperature equilibrium for at least one hour. If the scanner/scale is already at room temperature, allow at least 15 minutes for acclimatization. 4.
Calibrating the Scale (Pounds & Kilograms) Figure 5-1. Calibration Switch Access Spider Calibration Switch 4. Press and release the Calibration Switch to place the scanner/scale in Calibration Mode. The scanner/scale will sound a tone indicating it is in Calibration Mode. If the motor was spinning when you initiated Calibration Mode, the motor will stop and the Yellow LED will begin flashing indicating the scale is in Calibration Mode. The display will show the message “ESCL” (empty scale). 5.
8. The Yellow LED will extinguish for approximately 10 seconds and the Remote Display will alternately display and until the scale is ready to proceed. 9. If the calibration was successful, the speaker sounds a single tone, the Scale Status LED begins blinking again, and “End-” appears in the Remote Display. 10.
Calibration Verification (U.S. Pounds) Calibration Verification (U.S. Pounds) Once you have completed the calibration sequence, you may be required to perform these step-by-step verification procedures. These procedures follow the National Institute of Standards and Technology Handbook-44 guidelines for grocery scale installations. You may be required by state or local law to have these procedures performed by a certified technician or verified by a proper official.
Shift Test The Shift Test checks to ensure that items placed anywhere on the weighing surface of the scanner/scale are weighed properly. Refer to Figure 5-2 when performing this test. 1. Place and remove in succession, a ten-pound load on the center of each of the four quadrants (1, 2, 3, and 4 in Figure 5-2) of the scanner/scale’s weigh platter. Verify that a reading of between 9.99 and 10.01 lb registers under load and that the display returns to 0.00 between each load. 2.
Calibration Verification (U.S. Pounds) Increasing- Load Test (Phase 2) After completing the Shift Test, you must complete the Increasing Load Test using 20.0, 25.0 and 30.0 pounds of weight. NOTE The upper limit of the scale is configurable according to POS interface type and may not necessarily be set at 30 pounds, which is the standard setting. For this test, continue to place weights in five pound increments only up to the upper weight limit set for your scale. 1.
Decreasing-Load Test This test ensures that the scanner/scale responds properly when a heavy object is followed by a significantly smaller object. 1. Place a 30.0-pound load on the scale and verify that the display shows between 29.99 and 30.01 pounds. If the upper weight limit for your scale is not set at 30 pounds, begin by placing weight equaling your upper limit setting. NOTE 2. Remove weights to leave 20 pounds on the scale. Check that the display shows between 19.99 and 20.01. 3. Remove another 15.
Calibration Verification (Kilograms) Calibration Verification (Kilograms) Once you have completed the calibration sequence, you may be required to perform these step-by-step verification procedures. These procedures follow the National Institute of Standards and Technology Handbook-44 guidelines for grocery scale installations. You may be required by state or local law to have these procedures performed by a certified technician or verified by a proper official.
8. Place an additional 200 grams on the center of the weighing surface and check that the display reads 1.000 kg. 9. Increase the weight on the scale to 7.50 kg on the center of the weighing surface and check that the display reads between 7.495 and 7.505 kg. 10. Remove the weights and verify that the display reads 0.000 kg. You have completed the Increasing-Load Test (Phase 1).
Calibration Verification (Kilograms) Figure 5-3. European Shift Test (Metric) 2 3 1 3 2 1 5 4 4 5 Increasing- Load Test (Phase 2) After completing the Shift Test, you must complete the Increasing Load Test using 10.00, 12.50 and 15 kilograms of weight. NOTE The upper limit of the scale is configurable according to POS interface type and may not necessarily be set at 15 kilograms, which is the standard setting. For this test, continue to place weights in 2.
5. You have completed phase two of the increasing load test. Blanking Test This test ensures that the scanner/scale will indicate its weighing capability has been exceeded if a weight greater than 0.82 over its maximum upper weight limit is placed upon the unit. 1. Place weights that total the upper limit plus 0.82 kilograms on the weigh platter. For example: If the upper limit is set at 15 kilograms, place weights equaling 15.82 kilograms. 2.
Calibration Verification (Kilograms) Decreasing-Load Test This test ensures that the scanner/scale responds properly when a heavy object is followed by a significantly smaller object. 1. Place weights that total 15.8 kilograms. If the upper weight limit for your scale is not set at 15 kilograms, begin by placing weight equaling your upper limit setting plus 0.8 kilograms. NOTE 2. Remove weights to leave 10 kilograms on the scale and verify that the display shows between 9.990 and 10.010 kilograms. 3.
NOTES 5-16 MagellanTM 8300/8400
Chapter 6 Programming Introduction to Label Programming The programming bar code labels contained in this manual will allow you to customize and configure features and settings for your scanner (scanner/scale). To ensure full compatibility and proper function, use only the programming bar codes in this manual and other product-specific publications to program scanner features.
Integrating the Scanner With Your Host System Your scanner MUST be equipped with the correct hardware (interface board, cable, etc.) to properly communicate with your host system. Contact your dealer for information if you have questions about your scanner’s hardware compatibility. You may also want to contact the dealer or your system administrator if you have no record of how your scanner was pre-programmed at the factory.
Integrating the Scanner With Your Host Sys- • CAUTION Interface Related Features — are the mandatory settings necessary to allow communication with your host terminal. Examples of these settings are: RS-232 baud rate and parity. It is possible, via programming bar codes, to change the interface type (for example: from RS-232 to IBM Port 17).
Programming Overview The scanner’s programmable feature settings can be modified to accommodate your system’s unique requirements. These settings can be communicated to the scanner in one of three ways: 1. Commands can be sent directly from the host. A limited set of host commands are available. Refer to Appendix D for more details or contact Tech Support. 2. Programming bar code labels can also be used to modify the scanner’s programmable settings.
Programming Overview What Is Programming Mode? Programming Mode is a state in which the scanner must be placed in order to accept commands via programming bar code labels. When programming using the bar code labels in this manual, the scanner is typically placed in Programming Mode by scanning the SWITCH label. While in the Programming Mode, the scanner only recognizes ONLY the special programming bar codes contained in this programming guide.
Programming Session A typical programming session is conducted as follows: 1. Scan the SWITCH bar code to place the scanner in Programming Mode. Depending upon its current programming, the scanner may emit a beep or beeps, indicating it has read the bar code and the scanner (top) green LED will flash on and off slowly while the scanner remains in Programming Mode. Normal scanning functions are disabled. 2. Scan the programming bar code(s) that is (are) specially encoded to make the desired changes.
Programming Overview NOTE It is recommended that programming sessions be limited to one feature at a time. Should you make a mistake in the programming sequence, it can be difficult to discover where an error has been made if several features are programmed at once. Additionally, it can be confusing to determine which features may or may not have been successfully set following such a session. 3. Scan the SWITCH bar code to save any new settings and exit Programming Mode.
Programming Sequence To modify a scanner feature (item), the programming bar codes contained in this manual must be scanned in a given sequence depending upon the feature being programmed (as shown in Table 6-1). There are three possible programming sequences: NOTE If the scanner’s interface type must be changed, always be sure that interface configuration is the FIRST item scanned during a programming session.
Programming Overview Table 6-1. Programming Sequence SET A ITEM TAG ITEM VALUE END/RESET 1 2 3 SWITCH ENABLE NEW FEATURE SWITCH 1 2 345 6 0 B SWITCH C ENABLE NEW FEATURE USING THE FOLLOWING SETTINGS...
LED and Beeper Indicators The scanner provides a set of indicators that verify/announce the various scanner functions. If You Make a Mistake... If, during a programming session, you find that you are unsure of the scanner’s settings or wish to reset the scanner’s configuration, use the Return to Factory Settings label below to return the scanner’s configuration to the factory settings. Scanning this label will also reset any changes made during previous programming sessions.
If You Make a Mistake... Test Mode Use this feature to place the scanner into a testing, or “demo” mode. This special mode disables the scanner interface, meaning that bar code data is not sent out to the host via the scanner interface. This allows the bar code to be scanned continuously without requiring a response from the POS terminal. To return the scanner to normal function, scan the TEST MODE = DISABLE bar code below.
General Scanner Features Scanner Button Options Allows configuration of the scanner (volume) button to different modes of operation. • Disable Scanner Button — Disables all button functions • Enable Standard Functions — Enables volume, tone, and reset. • Enable Reset Only — The button’s sole function will be to reset the scanner. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
General Scanner Features Scanner Button Options — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Double Read Timeout The Double Read Timeout feature sets a time limit that determines how much time must pass before reading the same label again (e.g. two identical items in succession). To set the Double Read Timeout: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
General Scanner Features Double Read Timeout — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Laser Timeout The laser timeout feature sets the time for switching the visible laser diodes (VLDs) off if the scanner is idle. Using this feature can prolong the life of the VLDs. To set the Laser Timeout: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
General Scanner Features Laser Timeout — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Motor Timeout The Motor Timeout feature sets the time for automatically switching the motor off when the scanner is not in use. Laser safety requires that the laser switch off before the motor. If you set the motor timeout shorter than the laser timeout, the motor and the laser will both shut off when the motor timeout expires. NOTE To set the Motor Timeout: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
General Scanner Features Motor Timeout — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Motor Timeout — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
General Scanner Features Label Gone Timeout Specifies the amount of time that data segments are stored by the software before being discarded if a label has not been successfully decoded during the current “label in volume session,” which is defined as the time between when the label gone time is first started until the label gone timer expires. To set the Label Gone Timeout: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
Label Gone Timeout — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
General Scanner Features Label Gone Timeout — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Auxiliary Port Mode Selects the usage for the scanner’s optional auxilliary port. The choices listed below are mutually exclusive (only one option can be active at a time). • Disabled — Port is inactive • External Handheld Input — Supports Datalogic® handheld scanners (QuickScan 1000, QuickScan 6000, PowerScan) as well as other models such as the Symbol® HotShot. Call your dealer for more information about supported devices.
General Scanner Features Auxiliary Port Mode — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Auxiliary Port Baud Rate Specifies the baud rate of the auxillary port when operating in PIR/CT mode. PIR/CT is a value-added feature which may not have been activated on your model. NOTE To specify the Auxiliary Port Baud Rate: 1. Scan the SWITCH bar code. 2. Scan the desired baud rate from the bar codes below and on the immediately following pages. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
General Scanner Features Auxiliary Port Baud Rate — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Auxiliary Port Baud Rate — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
General Scanner Features Auxiliary Port Baud Rate — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Laser Failure Mode This configuration item selects whether the scanner should continue operating if only one laser is functional. (The scanner has two lasers: One for the horizontal window, and one for the vertical window.) Options for this feature are: • Single Laser Failure OK — The scanner can still operate even if one laser is no longer functional. In this mode the scanner will read only from the window associated with the operational laser.
General Scanner Features Productivity Index Reporting (PIR)/Cashier Training (CT) When PIR/CT is enabled, label quality data is appended to decoded data before being presented to the POS. The PIR feature allows the scanner to provide information to an external computer indicating how easy the label was to read. CT allows the scanner to provide feedback to the cashier on how to scan in a more ergonomic fashion. This value-added feature is a factory-programmed option.
Indication Features Green LED Idle State This feature specifies the state of the green scanner LED when the scanner is idle and ready to read a label. Options are: • Off • On dim To set the LED Idle State: 1. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 2. Complete the programming sequence by scanning the SWITCH bar code.
Indication Features Power-up Beep Control Specifies the type of audible indication that is made when entering scanner-active mode on power-up. Choices are: • No beep • One beep • Three beeps To set the Power-up Beep: 1. Scan the SWITCH bar code. 2. Scan your selection from the three bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Good Read Beep Control This feature enables/disables scanner beep upon successfully decoding of a label. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the two bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Indication Features Good Read Beep Frequency Adjusts the scanner’s good read beep to sound at low, medium, or high frequency (controls the beeper’s pitch/tone). • Low = 660 Hz • Medium = 860 Hz • High = 1050 Hz To set the Good Read Beep Frequency: 1. Scan the SWITCH bar code. 2. Scan your selection from the three bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Good Read Beep Frequency — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Indication Features Good Read Beep Length Specifies the duration of a good read beep. To set the good read beep length: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET GOOD READ BEEP LENGTH. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired good read beep length setting.
Good Read Beep Volume Selects the beeper volume upon a good read beep. There are five selectable volumes, with each volume increment adding approximately five decibels to the previous level: • 0 = Lowest Volume • 1 = Medium-Low Volume • 2 = Medium Volume • 3 = Highest Volume To set the Good Read Beep Volume: 1. Scan the SWITCH bar code. 2. Scan your selected volume bar code from this or the following pages.
Indication Features Good Read Beep Volume — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Good Read Beep Volume — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Indication Features Good Read When to Indicate This feature specifies when the scanner will provide indication (beep and/ or flash its green LED) upon successfully reading a bar code. • Good Read = Indicate after decode • Good Read = Indicate after transmit • Good Read = Indicate after CTS goes inactive, then active The “Indicate after CTS goes inactive...” mode applies to RS-232 STD and RS232 WN interfaces only.
Good Read When to Indicate — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Scale Features Scale Features Scale Enable Use this feature to enable or disable scale operation. Recalibration/recertification may be required when adding scale functionality. Consult your local Weights and Measures authority. NOTE If this feature is enabled the scanner will expect that it is to function as a scanner-scale, and will indicate an error if it is not a scale-equipped unit. See Chapter 4, Error Codes, for more information. To set this feature: 1. Scan the SWITCH bar code. 2.
Scale Enforced Zero Return This feature enables/disables the enforced zero return of the scale. Three settings are available for this feature: • Disable • Scale Must Return to Zero Weight Within Two Minutes — Scale will require re-zeroing if a non-zero weight is left on for more than two minutes or if the scale is below zero.
Scale Features Scale Enforced Zero Return — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Scale Enforced Zero Return — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Scale Features Scale Interface Type Use this feature to select the scale interface type. Choices are: • No Scale Interface • RS-232 — SASI • RS-232 — ICL To set the Scale Interface Type: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Scale Interface Type — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Scale Features Scale Calibration Notification When enabled, this feature allows the host to be notified of a calibration event. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the two bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Scale Intercharacter Delay Sets the delay between the end of one character and the beginning of the next, in 10 millisecond increments. To specify the intercharacter delay: 1. Scan the SWITCH bar code. 2. Scan the bar code below, SET KEYBOARD WEDGE INTERCHARACTER DELAY. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired delay.
Scale Features Remote Display — Enable/Disable The scanner-scale can be configured to operate with or without a Remote Display. Recalibration/recertification may be required when adding a Remote Display. Consult your local Weights and Measures authority. NOTE If this feature is enabled the scanner-scale will expect that it is connected to a Remote Display, and will indicate an error if one is not. See Chapter 4, Error Codes, for more information.
EAS Features EAS Active State Specifies the active state polarity of EAS (Electronic Article Survellance); the inactive state is its opposite polarity. EAS output goes active during the good read indication of a bar code, allowing the EAS device to deactivate a tag on the product. To set the EAS Active State: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
EAS Features EAS Timeout Specifies the amount of time that an EAS (Electronic Article Survellance) signal is held in its active state for a good read indication. To set the EAS Timeout: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAS TIMEOUT below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired EAS Timeout duration.
Interface Related Features Interface Type Specifies the current scanner interface. Selections are: INTERFACE (I/F) TYPE RS-232 Standard RS-232 Wincor-Nixdorf RS-232 Single Cable OEM USB IBM Port 17 I/F I.D. NUMBERa 05 12 20 45 04 Keyboard Wedge A Keyboard Wedge B Keyboard Wedge C Keyboard Wedge D Keyboard Wedge E I/F I.D.
Interface Related Features Interface Type — continued NOTE A new scanner may have been shipped from the factory with a Null Interface (no interface type selected) to ensure system compatibility at installation. In this case, the correct Interface Type programming bar code must be scanned first before the scanner can be used with a POS system. NOTE If the scanner’s interface type must be changed, always be sure that interface configuration is the FIRST item scanned during a programming session.
Interface Type — continued 4. Complete the programming sequence by scanning the SWITCH bar code. NOTE Once the correct interface has been set, it will be necessary to proceed to the appropriate pages in this manual that select parameters and options for that interface. For example, if RS-232 is selected, turn to the pages in this manual headed as features specific to the RS-232 interface. 5. Connect new interface cable(s).
Interface Related Features RS-232 Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
RS-232 Wincor-Nixdorf Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Interface Related Features RS-232 Single Cable Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
OEM USB Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED. Single cable installations require connection at the POS Terminal (host) port.
Interface Related Features IBM Port 17 Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
IBM Port 5B Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Interface Related Features IBM Port 9B Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
USB Keyboard Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Interface Related Features Keyboard Wedge A Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Keyboard Wedge B Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Interface Related Features Keyboard Wedge C Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Keyboard Wedge D Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Interface Related Features Keyboard Wedge E Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Keyboard Wedge F Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Interface Related Features Keyboard Wedge G Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Keyboard Wedge H Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Interface Related Features Keyboard Wedge I Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Keyboard Wedge J Interface Selection Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. CAUTION Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED.
Interface Related Features Maximum Host-Transmitted Message Length Specifies the maximum number of data characters allowed in messages transmitted to the host. To set the Maximum Host-Transmitted Message Length: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET MAXIMUM HOST-TRANSMITTED MESSAGE LENGTH below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Number of Host Transmission Buffers Specifies the number of host transmission(s) that may be buffered. By buffering data from a bar code, the scanner can continue to read a new bar code while the old one is being transmitted to the host. Selecting BUFFERS = 1 means that the first bar code must be transmitted before a new one can be read. A selection of BUFFERS = 2 means that a new bar code can be read while data from the first bar code is transmitted.
Interface Related Features AIM ID AIM label identifiers (as opposed to custom characters you select yourself as with label identifiers) can be included with scanned bar code data. AIM label identifiers consist of three characters as follows: • A close brace character (ASCII ‘]’), followed by...
AIM ID — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Interface Related Features Label ID Control A Label ID is used to identify a barcode (symbology) type. See Appendix D, Default Settings, for a listing for common symbologies. It can be appended previous to or following the transmitted barcode data depending upon how this option is enabled. This feature provides options for configuring custom Label IDs individually per symbology.
Label ID Control — continued • Scan 4’ • Scan ‘0’ • Scan ‘0’ • Scan ‘0’ • Scan ‘0’ • Scan the Switch label Figure 6-2. Label ID Position Options SCANNER Prefix Label ID Aim ID Bar Code Data Label ID Suffix OR Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Interface Related Features Label ID Control — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Global Prefix This feature specifies the prefix that is added to beginning of label transmission. To specify the Global Prefix Character(s): 1. Scan the SWITCH bar code. 2. Scan the bar code, SET GLOBAL PREFIX below. You’ll need to cover any unused bar codes to ensure the scanner reads only the bar code you intend to scan. 3. Scan the appropriate characters/digits from the keypad in Appendix C that represent the hex designation for the desired character(s).
Interface Related Features Global Prefix — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Global Suffix This feature specifies the suffix that is added to end of a label transmission. Three standard options are available below. Contact your dealer for other alternate settings for this feature. • No Global Suffix • CR — Carriage Return • CR LF — Carriage Return, Line Feed To set the Global Suffix: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. 3. Complete the programming sequence by scanning the SWITCH bar code.
Interface Related Features Global Suffix — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Case Conversion Changes the case of all alphabetic characters to upper or lower case. Choices are: • No case conversion • Upper case • Lower case To configure this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the case conversion bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Interface Related Features Case Conversion — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
IBM Features IBM Interface Options IBM interfaces offer specific control over interaction with certain devices. The OEM USB interface provides its own set of options. Refer to the feature, OEM USB Scanner Device Type, in this chapter. NOTE Options for this feature are as follows: • FULL host interface support — Accepts scanner and scale configuration host commands. • Ignore host interface configuration of scanner and scale — Ignores all scanner and scale configuration host commands.
IBM Features IBM Number of Host Resets Specifies how many consecutive resets are processed before the scanner starts a five-second period during which a user is allowed to enter labelprogramming mode and configure the scanner. To set the number of host resets: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET IBM NUMBER OF HOST RESETS. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
IBM Scale Address This feature applies to IBM Port 17 ONLY. NOTE Specifies IBM scale address for IBM Port 17. The following three addresses are available: • 6A • 6B • 6E To set the IBM Scale Address: 1. Scan the SWITCH bar code. 2. Scan the bar code below or from the following page that represents the desired scale address designation. 3. Complete the programming sequence by scanning the SWITCH bar code.
IBM Features IBM Scale Address — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
IBM Transmit Labels in Code 39 Format This feature enables/disables scanner's ability to set a symbology identifier for a specified label to Code 39 before transmitting that label data to an IBM host. This applies to: Code 128, Code 93 and Codabar for IBM Port 5B; Code 93 and Codabar for IBM Port 9B. When enabled, this feature has no effect on IBM Port 17. NOTE To enable/disable the IBM Transmit Labels in Code 39 Format feature: 1. Scan the SWITCH bar code. 2.
IBM Features IBM Label Slicing Control Enables/disables the slicing of IBM-46XX host transmission data into multiple pieces when a label is longer than the length specified by IBM Maximum Label Slice Length. Options are: • Disable Label Slicing — Send data to host in one piece. • Enable Label Slicing — Slice the host data into multiple pieces when necessary. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
IBM Maximum Label Slice Length Specifies the maximum allowable length of host transmit data in each sliced frame. This setting only applies when IBM Label Slicing Control is enabled. NOTE 1. Scan the SWITCH bar code. 2. Scan the bar code below, SET IBM MAXIMUM LABEL SLICE LENGTH. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
IBM Features OEM USB Scanner Device Type The OEM USB protocol allows for the scanner to be identified as one of two different types of barcode scanners. Depending on what other scanners you may already have connected to a USB POS, you may need to change this setting to enable all scanners to communicate. Options are: • Table Top Scanner • Handheld Scanner To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
RS-232 Features RS-232 Baud Rate This feature selects the baud rate required for sending and receiving data. Single cable interfaces are limited to Baud Rate selections up to 19200. They cannot communicate at Baud Rates of 38400 and up. NOTE To specify the RS-232 Baud Rate: 1. Scan the SWITCH bar code. 2. Scan the desired baud rate from the bar codes below and on the immediately following pages.
RS-232 Features RS-232 Baud Rate — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 Baud Rate — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 Features RS-232 Baud Rate — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 Number of Data Bits Specifies number of data bits required for sending and receiving data. 8 data bits with 2 stop bits and parity enabled is not a valid configuration. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below representing the desired Data Bit setting. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
RS-232 Features RS-232 Number of Stop Bits Specifies number of stop bits required for sending and receiving data. 8 data bits with 2 stop bits and parity enabled is not a valid configuration. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below representing the desired Stop Bit setting. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
RS-232 Parity Specifies parity required for sending and receiving data. 8 data bits with 2 stop bits and parity enabled is not a valid configuration. NOTE Options for this setting are: • RS-232 PARITY = NONE • RS-232 PARITY = EVEN • RS-232 PARITY = ODD To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below or on the following pages representing the desired Parity setting.
RS-232 Features RS-232 Parity — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 Hardware Control Enables/disables use of the RS-232 CTS signal for flow control and/or scan control. Options are: • Disable — The scanner transmits to the host regardless of any activity on the CTS line. • Enable CTS Flow Control — The CTS signal controls transmission of data to the host. • Enable CTS Scan Control — The CTS line must be active for scanner to read and transmit data.
RS-232 Features RS-232 Hardware Control — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 Hardware Control — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 Features RS-232 Intercharacter Delay Specifies delay between the end of one character and the beginning of the next in 10-millisecond increments. To set the RS-232 Intercharacter Delay: 1. Scan the SWITCH bar code. 2. Scan the bar code below, SET RS-232 INTERCHARACTER DELAY. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
RS-232 Software Flow Control Enables/disables RS-232 Flow Control using XON/ XOFF characters. . This item will be ignored when the feature, RS-232 NAK Character, is enabled NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RS-232 Features RS-232 Host Echo When enabled, this feature passes all data through the scanner to the host as it comes in. This feature is used for applications where “daisy chaining” of RS-232 devices onto the same cable is necessary.
RS-232 Host Echo Quiet Interval This setting specifies the time interval of RS-232 channel inactivity which must transpire before the scanner will break the host echo loop to transmit the bar code data that has just been scanned to the host. • 0 - 100 = Time in 10-millisecond increments. To set the Host Echo Quiet Interval: 1. Scan the SWITCH bar code. 2. Scan the bar code below, SET RS-232 HOST ECHO QUIET INTERVAL.
RS-232 Features RS-232 Ignore Host Commands When set to ignore host commands, the scanner will ignore all host commands except for the minimum set necessary to keep the interface active, transmit labels, and transmit scale information. For normal operation of the interface, disable this feature. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
RS-232 TTL Specifies whether RS-232 interface provides TTL levels on the output pins TxD and RTS. Choices are: • Normal RS-232 levels • TTL levels To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below which represents the desired setting for this feature. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RS-232 Features RS-232 TTL Invert Enables/disables inversion of TTL. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below which represents the desired setting for this feature. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RS-232 ICL DC1 Character Delay Enable Enables/disables the ability of the scanner to delay a DC1 response for 40 milliseconds. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below which represents the desired setting for this feature. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RS-232 Features RS-232 Team POS ICL Scale Enables/disables the ability of the scanner to enter TEAM POS ICL Scale mode. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below which represents the desired setting for this feature. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RS-232 Beep on ASCII BEL Enables/disables ability of scanner to beep (sound a good read tone) on receiving an ASCII BEL (07 hex). • Disable • Enable To enable/disable this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RS-232 Features RS-232 Beep After Weigh Enables/disables the ability of the scanner to beep after weight data is transmitted to the host. Scale interfaces that support this item are: RS-232 ICL, RS-232 SASI, and RS-232 Single Cable. To enable/disable the Beep After Weigh feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
RS-232 Beep on Not on File Select for the host to beep (or not) when a not-on-file condition is detected by the host. This feature is also applicable to single cable RS-232.
RS-232 Features RS-232 ACK NAK Enable This enables/disables the ability of the scanner to support the RS-232 ACK/NAK protocol. When configured, the scanner and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error.
RS-232 ACK NAK Enable — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 Features RS-232 ACK Character This feature specifies which ASCII character will be used as an ACK character. NOTE DO NOT set this feature to use previously defined characters such as XON, XOFF or host commands as this will conflict with normal operation of these characters. 8-bit data is not recognized when the feature, RS-232 Number of Data Bits, is set to 7 data bits. To specify the RS-232 ACK Character: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET RS-232 ACK CHARACTER below.
RS-232 NAK Character This feature specifies which ASCII character will be used as a NAK character. NOTE DO NOT set this feature to use previously defined characters such as XON, XOFF or host commands as this will conflict with normal operation of these characters. 8-bit data is not recognized when the feature, RS-232 Number of Data Bits, is set to 7 data bits. To specify the RS-232 NAK Character: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET RS-232 NAK CHARACTER below.
RS-232 Features RS-232 Retry on ACK NAK Timeout This option specifies the action scanner performs on expiration of the RS232 ACK NAK Timeout Value. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
RS-232 ACK NAK Timeout Value This item specifies the time the scanner will wait for an ACK character from the host following a label transmission. • 0 = Infinite timeout • 1 - 75 = Timeout in 200-millisecond increments To set the ACK NAK Timeout Value: 1. Scan the SWITCH bar code. 2. Scan the bar code below, SET RS-232 ACK NAK TIMEOUT VALUE. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
RS-232 Features RS-232 ACK NAK Retry Count This feature sets the number of times for the scanner to retry a label transmission under a retry condition. To set the RS-232 ACK NAK Retry Count: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET RS-232 ACK NAK RETRY COUNT below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
RS-232 ACK NAK Error Handling This item specifies the method the scanner will use to handle errors detected while waiting to receive the ACK character from the host. Errors include unrecognized host commands and communication errors such as parity or framing errors. • Ignore Errors (recommended setting) • Assume ACK (risk of lost label data) • Assume NAK (risk of duplicate label) To select the option for RS-232 ACK NAK Error Handling: 1. Scan the SWITCH bar code. 2.
RS-232 Features RS-232 ACK NAK Error Handling — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
RS-232 Indicate Transmission Failure Enables/disables an audible error indication upon a transmission failure.
Single Cable RS-232 Options Single Cable RS-232 Options The RS-232 Single Cable interface shares some configuration options with other RS-232 interfaces.
Single Cable RS-232 Scanner Only Protocol This sets the type of interface protocol that will be used in Single Cable RS-232. Options are: • Scanner/scale RS-232 protocol • Scanner only RS-232 protocol To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below representing the desired option. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Single Cable RS-232 Options Single Cable RS-232 Stale Weight Timeout Specifies the amount of time (in 10 msec increments) that scale data is presented to the host before being discarded. To set the Timeout: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Single Cable RS-232 Stale Weight Timeout — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Single Cable RS-232 Options Single Cable RS-232 Scale — Transmit Weight Digits Specifies whether the scale transmits weight data as five digits or as four digits. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below representing the desired option. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Single Cable Manufacturer Extensions Enables/Disables manufacturer1 extensions to the Single Cable RS-232 interface. These extensions communicate scale calibration information to the host. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Single Cable RS-232 Options Single Cable Pacesetter Plus Enable Enables/disables the scanner’s ability to send Pacesetter Plus information as trailers to UPC/EAN label data. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Single Cable RS-232 RTS CTS Selection Specifies how RTS and CTS are used to control the data flow. RTS is controlled by the Scanner and can be continuously held high/low, or can be asserted during label transmission. The scanner looks at CTS, as the configuration values state, to determine when to send label data.
Single Cable RS-232 Options Single Cable RS-232 RTS CTS Selection — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Single Cable RS-232 RTS CTS Selection — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Single Cable RS-232 Options Single Cable RS-232 Use BCC Enables/disables the ability of the scanner to use BCC. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Single Cable RS-232 Use ACK/NAK Enables/disables the ability of the scanner to use ACK/NAK. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Single Cable RS-232 Options Single Cable RS-232 Use STX Enables/disables the ability of the scanner to use STX. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Set Single Cable RS-232 STX Character This feature selects the STX character. To specify the STX Character: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET SINGLE CABLE RS-232 STX CHARACTER below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3. Scan the appropriate characters/digits from the keypad in Appendix C that represent the decimal designation for the desired character.
Single Cable RS-232 Options Set Single Cable RS-232 ETX Character Allows selection of the ETX character. To specify the ETX Character: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET SINGLE CABLE RS-232 ETX CHARACTER below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3. Scan the appropriate characters/digits from the keypad in Appendix C that represent the decimal designation for the desired character.
Keyboard Wedge/USB Keyboard Features Features listed in this section apply to both the Keyboard Wedge and USB Keyboard interfaces unless otherwise noted. Keyboard Interface — Keyboard Layout This feature specifies the country/language to be supported by the keyboard. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the appropriate country bar code from the following pages.
Keyboard Wedge/USB Keyboard Features Keyboard Interface — Keyboard Layout — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Keyboard Interface — Keyboard Layout — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Keyboard Wedge/USB Keyboard Features Keyboard Interface — Keyboard Layout — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Keyboard Interface — Keyboard Layout — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Keyboard Wedge/USB Keyboard Features Keyboard Interface — Keyboard Layout — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Keyboard Interface — Keyboard Layout — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Keyboard Wedge/USB Keyboard Features Keyboard Interface — Keyboard Layout — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Keyboard Interface — Keyboard Layout — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Keyboard Wedge/USB Keyboard Features Keyboard Interface — Keyboard Layout — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. KEYBOARD LAYOUT = POLAND Keyboard Interface Quiet Interval Specifies amount of time to look for keyboard activity before scanner breaks keyboard connection in order to transmit data to host. To set the Keyboard Interface Quiet Interval: 1. Scan the SWITCH bar code. 2.
Keyboard Interface Caps Lock State Specifies the format in which the scanner sends character data.. Choices are: • CAPS LOCK OFF — send character data in normal format. • CAPS LOCK ON — send character data in reverse case. • SHIFT LOCK ON — send character data in shifted case. This option only applies to Wedge G. For other interface this setting results in a CAPS LOCK OFF functionality. • CAPS LOCK COMPENSATION MODE — This only applies to the USB Keyboard Interface.
Keyboard Wedge/USB Keyboard Features Keyboard Interface Caps Lock State — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Keyboard Interface — Keyboard Simulation Enables/disables ability of scanner to perform host communications normally performed by attached keyboard. This feature does not apply to the USB Keyboard interface. NOTE All PCs check the keyboard status during the power-on Selftest. It is recommended that you enable this function if you are working without a keyboard installation. It simulates keyboard timing and passes the keyboard status to the PC during power-on. To set this feature: 1.
Keyboard Wedge/USB Keyboard Features Keyboard Interface — Control Characters Specifies how the scanner transmits ASCII control characters to the host. This feature does not apply to the USB Keyboard interface. NOTE Choices are: • Disable Control Characters • Enable transmission of control characters to host • Send characters between 00H and 1FH according to a special function-key mapping table.
Keyboard Interface — Control Characters — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Keyboard Wedge/USB Keyboard Features Keyboard Interface — Intercharacter Delay Sets the delay between the end of one character and the beginning of the next, in 10 millisecond increments. To specify the intercharacter delay: 1. Scan the SWITCH bar code. 2. Scan the bar code below, SET KEYBOARD WEDGE INTERCHARACTER DELAY. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Symbology Programming If the scanner’s interface type must be changed, always be sure that interface configuration is the FIRST item scanned during a programming session. (Selecting an interface type resets ALL other configuration items — including symbology programming — to the factory default for that interface type.) NOTE Coupon Control Used to control the method of processing coupon labels.
Symbology Programming Coupon Control — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
UPC-A Enable Enables/disables the ability of the scanner to decode UPC-A labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
UPC-A Enable UPC-A Number System Character Transmission Enables/disables transmission of a UPC-A number system character. This feature MUST be enabled for IBM interfaces for proper function. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
UPC-A Check Character Transmission Enables/disables transmission of a UPC-A check character. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
UPC-A Enable Expand UPC-A to EAN-13 Enables/disables expansion of UPC-A labels to EAN/JAN-13. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
UPC-A Label ID This feature specifies a UPC-A label ID to be added to bar code data. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-A LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
UPC-A Enable UPC-A 2-Digit Supplemental Label ID This feature specifies a UPC-A 2-Digit Supplemental label ID to be added to bar code data. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-A 2-DIGIT SUPPLEMENTAL LABEL ID below.
UPC-A 5-Digit Supplemental Label ID This feature specifies a UPC-A 5-Digit Supplemental label ID to be added to bar code data. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-A 5-DIGIT SUPPLEMENTAL LABEL ID below.
UPC-A Enable UPC-A 128 Supplemental Label ID This feature specifies a UPC-A 128 Supplemental label ID to be added to bar code data. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-A 128 SUPPLEMENTAL LABEL ID below.
UPC-A Minimum Reads Specifies the minimum number of consecutive times a UPC-A label must be decoded before it is accepted as a good read. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code representing the desired option below or on the following pages. You’ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.
UPC-A Enable UPC-A Minimum Reads — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
UPC-E Enable Enables/disables the ability of the scanner to decode UPC-E labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
UPC-E Enable UPC-E Number System Character Transmission Enables/disables transmission of a UPC-E number system character. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
UPC-E Check Character Transmission Enables/disables transmission of a UPC-E check character. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
UPC-E Enable Expand UPC-E to UPC-A Enables/disables expansion of UPC-E labels to UPC-A. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Expand UPC-E to EAN-13 Enables/disables expansion of UPC-E labels to EAN/JAN-13. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
UPC-E Enable UPC-E Label ID This feature specifies a UPC-E label ID to be added to bar code data. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-E LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
UPC-E 2-Digit Supplemental Label ID This feature specifies a UPC-E 2-Digit Supplemental label ID to be added to bar code data. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-E 2-DIGIT SUPPLEMENTAL LABEL ID below.
UPC-E Enable UPC-E 5-Digit Supplemental Label ID This feature specifies a UPC-E 5-Digit Supplemental label ID to be added to bar code data. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-E 5-DIGIT SUPPLEMENTAL LABEL ID below.
UPC-E 128 Supplemental Label ID This feature specifies a UPC-E 128 Supplemental label ID to be added to bar code data. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET UPC-E 128 SUPPLEMENTAL LABEL ID below.
UPC-E Enable UPC-E Minimum Reads Specifies the minimum number of consecutive times a UPC-E label must be decoded before it is accepted as a good read. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code representing the desired option below or on the following pages. You’ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.
UPC-E Minimum Reads — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
EAN-13 Enable EAN-13 Enable Enables/disables the ability of the scanner to decode EAN/JAN-13 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAN-13 First Character Transmission Enables/disables transmission of EAN/JAN-13 first character. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAN-13 Enable EAN-13 Check Character Transmission Enables/disables transmission of an EAN/JAN-13 check character. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAN-13 ISBN Conversion Enable Enables/disables conversion of EAN/JAN-13 labels starting with 978 to Bookland ISBN labels. If any add-on information is present on the label prior to the conversion to ISBN, the add-on data will be discarded. Only the base label will be converted. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
EAN-13 Enable EAN 13 Label ID This feature specifies an EAN 13 label ID to be added to bar code data. To set this feature: The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN 13 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
EAN-13 2-Digit Supplemental Label ID This feature specifies an EAN-13 2-Digit Supplemental label ID to be added to bar code data. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN-13 2-DIGIT SUPPLEMENTAL LABEL ID below.
EAN-13 Enable EAN-13 5-Digit Supplemental Label ID This feature specifies an EAN-13 5-Digit Supplemental label ID to be added to bar code data. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN-13 5-DIGIT SUPPLEMENTAL LABEL ID below.
EAN-13 128 Supplemental Label ID This feature specifies an EAN-13 128 Supplemental label ID to be added to bar code data. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN-13 128 SUPPLEMENTAL LABEL ID = DISABLE below.
EAN-13 Enable EAN-13 Minimum Reads Specifies the minimum number of consecutive times an EAN-13 label must be decoded before it is accepted as a good read. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code representing the desired option below or on the following pages. You’ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.
EAN-13 Minimum Reads — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
EAN-13 Enable Bookland Label ID This feature specifies a Bookland label ID to be added to bar code data. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET BOOKLAND LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
EAN-8 Enable Enables/disables the ability of the scanner to decode EAN/JAN-8 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAN-8 Enable EAN-8 Check Character Transmission Enables/disables transmission of an EAN/JAN-8 check character. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Expand EAN-8 to EAN-13 Enables/disables expansion of EAN/JAN-8 labels to EAN/JAN-13. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAN-8 Enable EAN-8/JAN-8 Guard Insertion Enables/Disables the ability of the scanner to insert a guard pattern into an otherwise complete EAN-8 segment it has received. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAN-8/JAN-8 Guard Substitution Enables/disables the ability of the scanner to substitute a guard pattern for even-parity 6 when an EAN-8/JAN-8 label is presented. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAN-8 Enable EAN-8/JAN-8 Both Guards Substitution Enables/disables the ability of the scanner to find an EAN/JAN8 guard pattern in cases where the EAN/JAN8 margin makes the guard look like a character. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
EAN-8 Stitch Exact Label Halves When enabled, this allows the scanner the ability to stitch exact EAN-8 label haves with no overlapping characters. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAN-8 Enable EAN-8 Stitch Unlike Label Halves When enabled, this allows the scanner the ability to stitch two EAN-8 label halves together that may contain differing characters. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAN 8 Label ID This feature specifies an EAN 8 label ID to be added to bar code data. To set this feature: The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN 8 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
EAN-8 Enable EAN-8 2-Digit Supplemental Label ID This feature specifies an EAN-8 2-Digit Supplemental label ID to be added to bar code data. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN-8 2-DIGIT SUPPLEMENTAL LABEL ID below.
EAN-8 5-Digit Supplemental Label ID This feature specifies an EAN-8 5-Digit Supplemental label ID to be added to bar code data. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN-8 5-DIGIT SUPPLEMENTAL LABEL ID below.
EAN-8 Enable EAN-8 128 Supplemental Label ID This feature specifies an EAN-8 128 Supplemental label ID to be added to bar code data. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN-8 128 SUPPLEMENTAL LABEL ID below.
EAN-8 Decoding Levels Decoding levels allow the decoder to be set to perform at one of four selectable levels: • Very Conservative — Slower scan time, virtually eleminates misreads. The most secure setting. • Slightly More Aggressive — Faster scanning, more aggressive, yet minimizes misreads. • Moderately Aggressive — Even faster scanning, even more aggressive. • Very Aggressive — Fastest scan speed, most aggressive.
EAN-8 Enable EAN-8 Decoding Levels — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
EAN-8 Decoding Levels — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
EAN-8 Enable EAN-8 Minimum Reads Specifies the minimum number of consecutive times an EAN-8 label must be decoded before it is accepted as a good read. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code representing the desired option below or on the following pages. You’ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.
EAN-8 Minimum Reads — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
EAN-8 Enable EAN-8 Minimum Segment Length Specifies the minimum number of characters necessary in an EAN-8/ JAN-8 label segment in order for the scanner to accept a label for decoding. Selectable from 5 to 15 characters. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code representing the desired option below or on the following pages. You’ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan.
EAN-8 Minimum Segment Length — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
EAN-8 Enable EAN-8 Minimum Segment Length — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
EAN-8 Minimum Segment Length — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
EAN-8 Enable EAN-8 Minimum Segment Length — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
EAN-8 Minimum Segment Length — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Other UPC/EAN Options Other UPC/EAN Options The following pages contain other selectable features for UPC/EAN symbologies: • Price Weight Check • In-Store Label Minimum Reads • Enable EAN Two Label • EAN Two Label Minimum Reads • Addons Product Reference Guide 6-217
Price Weight Check Enables/disables calculation and verification of price/weight check digits. Applies to all UPC-A and EAN/JAN-13 labels with eligible1 Number System/First Character digits. Options are: • Disable • 4-digit price/weight • 5-digit price/weight • 4-digit European price/weight • 5-digit European price/weight To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code representing the desired option below or on the following pages.
Other UPC/EAN Options Price Weight Check — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Price Weight Check — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Other UPC/EAN Options In-Store Label Minimum Reads Specifies the minimum number of consecutive times an In-Store1 label must be decoded before it is accepted as a good read. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code representing the desired option below or on the following pages. You’ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.
In-Store Label Minimum Reads — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Other UPC/EAN Options Enable EAN Two Label Enables/disables the ability of the scanner to decode EAN two-label pairs. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
EAN Two Label Combined Transmission Enables/disables the transmitting of an EAN two label pair as one label. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code. Contact Customer Support for details about advanced programming for this feature.
Other UPC/EAN Options UPC/EAN Guard Insertion Enables/Disables the ability of the scanner to insert either a missing leading or trailing guard on an otherwise complete UPC-A/EAN-13 segment it has received. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
UPC/EAN Stitch Exact Label Halves When enabled, this allows the scanner the ability to stitch exact UPC-A / EAN-13 label haves with no overlapping characters. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Other UPC/EAN Options UPC/EAN Stitch Unlike Label Halves When enabled, this allows the scanner the ability to stitch two UPC-A / EAN-13 label halves together that may contain differing characters. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
UPC/EAN Character Reconstruction Enables/Disables character reconstruction on UPC/EAN labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Other UPC/EAN Options EAN Two Label Minimum Reads Specifies the minimum number of consecutive times an EAN Two Label bar code must be decoded before it is accepted as a good read. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code representing the desired option below or on the following pages. You’ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.
EAN Two Label Minimum Reads — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Other UPC/EAN Options UPC/EAN Correlation This feature enables/disables character correlation for UPC/EAN. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.
UPC/EAN Minimum Segment Length Specifies the minimum number of characters necessary in a UPC/EAN/ JAN label segment in order for the scanner to accept a label for decoding. Selectable from 5 to 15 characters. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code representing the desired option below or on the following pages. You’ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan.
Other UPC/EAN Options UPC/EAN Minimum Segment Length — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
UPC/EAN Minimum Segment Length — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Other UPC/EAN Options UPC/EAN Minimum Segment Length — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
UPC/EAN Minimum Segment Length — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Other UPC/EAN Options UPC/EAN Minimum Segment Length — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Addons Add-ons (or supplemental characters) are commonly added to the end of UPC/EAN bar codes. The scanner will read the add-ons if they are enabled and in the field of view. Three add-on types are supported: 2digit, 5-digit and Code 128 add-ons. Supported options are: None — This option directs the scanner to ignore add-on portion of a UPC/EAN bar code but still read the main portion of the bar code. 2 Digits — The scanner will optionally read 2-digit add-ons with the UPC/EAN label.
Other UPC/EAN Options Addons — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Addons — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Other UPC/EAN Options Addons — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Addon Timer When addons have been selected as optional, this feature sets the duration of time that the scanner can unsuccessfully look for an addon before proceeding to read a bar code. Timer duration is specified in 10ms increments. To set the Addon Timer: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET ADDON TIMER DURATION below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Other UPC/EAN Options 2-Digit Add-ons Minimum Reads Specifies the minimum number of times a 2-digit addon must be read before it is marked as valid and then combined with a base label. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code representing the desired option below or on the following pages. You’ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan.
2-Digit Add-ons Minimum Reads — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Other UPC/EAN Options 5-Digit Add-ons Minimum Reads Specifies the minimum number of times a 5-digit addon must be read before it is marked as valid and then combined with a base label. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code representing the desired option below or on the following pages. You’ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan.
5-Digit Add-ons Minimum Reads — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Other UPC/EAN Options Code 128 Add-ons Minimum Reads Specifies the minimum number of times a Code 128 addon must be read before it is marked as valid and then combined with a base label. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code representing the desired option below or on the following pages. You’ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan.
Code 128 Add-ons Minimum Reads — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
GTIN Enable GTIN Enable Enables/Disables the ability to convert UPCE, UPCA, EAN8, and EAN13 labels into the GTIN 14-character format. If add-on information is present on the base label prior to the conversion taking place, the add-on information will be appended to the converted GTIN bar code. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
GTIN Label ID This feature specifies a GTIN label ID to be added to bar code data when GTIN conversion is enabled. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET GTIN LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
GTIN Enable GTIN 2-Digit Supplemental Label ID This feature specifies a GTIN label ID to be added to bar code data when GTIN conversion is enabled and 2-digit supplemental addon bar code labels are converted. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET GTIN 2-DIGIT SUPPLEMENTAL LABEL ID below.
GTIN 5-Digit Supplemental Label ID This feature specifies a GTIN label ID to be added to bar code data when GTIN conversion is enabled and 5-digit supplemental addon bar code labels are converted. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET GTIN 5-DIGIT SUPPLEMENTAL LABEL ID below.
GTIN Enable GTIN Code 128 Supplemental Label ID This feature specifies a GTIN label ID to be added to bar code data when GTIN conversion is enabled and Code 128 supplemental addon bar code labels are converted The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET GTIN CODE 128 SUPPLEMENTAL LABEL ID below.
DataBar Omnidirectional Enable Enables/disables the ability of the scanner to decode DataBar Omnidirectional labels. This value-added feature is a factory-programmed option. Contact your dealer for information about upgrading your system to include this advanced capability. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
DataBar Omnidirectional Enable DataBar Omnidirectional/EAN-128 Emulation Enables/disables the ability of DataBar Omnidirectional to be transmitted as EAN-128. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
DataBar Omnidirectional Label ID This feature specifies an DataBar Omnidirectional label ID to be added to bar code data. To set this feature: The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET DataBar Omnidirectional LABEL ID below.
DataBar Omnidirectional Enable DataBar Omnidirectional Minimum Reads Specifies the minimum number of consecutive times an DataBar Omnidirectional label must be decoded before it is accepted as a good read. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code representing the desired option below or on the following pages. You’ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan.
DataBar Omnidirectional Minimum Reads — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
DataBar Expanded Enable DataBar Expanded Enable Enables/disables the ability of the scanner to decode DataBar Expanded labels. This value-added feature is a factory-programmed option. Contact your dealer for information about upgrading your system to include this advanced capability. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
DataBar Expanded EAN-128 Emulation Enables/disables EAN-128 emulation for DataBar Expanded. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
DataBar Expanded Enable DataBar Expanded Label ID This feature specifies an DataBar Expanded label ID to be added to bar code data. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET DataBar Expanded LABEL ID below.
DataBar Expanded Length Control This feature specifies either variable-length or fixed-length decoding for DataBar Expanded. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
DataBar Expanded Enable DataBar Expanded Length 1 Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length mode (see DataBar Expanded Length Control). Length includes the barcode’s check and data characters. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET DataBar Expanded LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
DataBar Expanded Length 2 Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed length mode (see DataBar Expanded Length Control). Length includes the barcode’s check and data characters. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET DataBar Expanded LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
DataBar Expanded Enable DataBar Expanded Minimum Reads Specifies the minimum number of consecutive times an DataBar Expanded label must be decoded before it is accepted as a good read. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code representing the desired option below or on the following pages. You’ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan.
DataBar Expanded Minimum Reads — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Code 39 Enable Code 39 Enable Enables/disables the ability of the scanner to decode Code 39 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 39 Start Stop Character Transmission Enables/disables transmission of Code 39 start and stop characters. This feature applies only when Code 39 Check Character Calculation is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 39 Enable Code 39 Check Character Calculation Enables/disables calculation and verification of an optional Code 39 check character. When disabled, any check character in label is treated as a data character. If check calculation is disabled, the risk is increased that a misread can occur. NOTE In particular, if you are using variable length stitching, it is important to use check character calculation to prevent misreads. To set this feature: 1. Scan the SWITCH bar code. 2.
Code 39 Check Character Transmission Enables/disables transmission of optional Code 39 check character. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 39 Enable Code 39 Full ASCII Enables/disables the ability of the scanner to translate to Code 39 full ASCII labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 39 Label ID This feature specifies a Code 39 label ID to be added to bar code data. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 39 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
Code 39 Enable Code 39 Require Quiet Zones When enabled, this feature requires that quiet zones (margins) be present for Code 39 labels. When disabled, quiet zones are optional. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 39 Length Control This feature specifies whether variable-length or fixed-length decoding will be set for Code 39. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code. You must now set the features Code 39 Length 1 and Code 39 Length 2.
Code 39 Enable Code 39 Length 1 Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length mode (see Code 39 Length Control). Length includes the barcode’s check and data characters. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 39 LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Code 39 Length 2 Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed length mode (see Code 39 Length Control). Length includes the barcode’s check and data characters. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 39 LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Code 39 Enable Code 39 Correlation This feature enables/disables character correlation for Code 39. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.
Code 39 Stitching Enables/disables stitching for Code 39 labels. When parts of a Code 39 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
Code 39 Enable Code 39 Minimum Reads Specifies the minimum number of consecutive times a Code 39 label must be decoded before it is accepted as a good read. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code representing the desired option below or on the following pages. You’ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.
Code 39 Minimum Reads — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Pharmacode 39 Enable Pharmacode 39 Enable Enables/disables the ability of the scanner to decode Italian Pharmacode 39 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Pharmacode 39 Start Stop Character Transmission Enables/ disables transmission of start and stop characters for Pharmacode 39. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Pharmacode 39 Enable Pharmacode 39 Check Character Transmission Enables/disables transmission of Pharmacode 39 check character. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Pharmacode 39 Label ID This feature specifies a Pharmacode 39 label ID to be added to bar code data. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET PHARMACODE 39 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
Code 128 Enable Code 128 Enable Enables/disables1 the ability of the scanner to decode Code 128 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code. CODE 128 = DISABLE CODE 128 = ENABLE 1.
Code 128 Transmit Function Characters Enables/disables transmission of Code 128 function characters 1, 2, 3, and 4. Disabled is the recommended setting for all interfaces. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 128 Enable Convert Code 128 to Code 39 Enables/disables conversion of Code 128 labels to Code 39. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 128 Label ID This feature specifies a Code 128 label ID to be added to bar code data.. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 128 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
Code 128 Enable Code 128 Length Control This feature specifies whether variable-length or fixed-length decoding will be set for Code 128. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 128 Length 1 Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length mode (see Code 128 Length Control). Length includes the barcode’s check and data characters. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 128 LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Code 128 Enable Code 128 Length 2 Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed length mode (see Code 128 Length Control). Length includes the barcode’s check and data characters. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 128 LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Code 128 Correlation This feature enables/disables character correlation for Code 128. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.
Code 128 Enable Code 128 Stitching Enables/disables stitching for Code 128 labels. When parts of a Code 128 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
Code 128 Minimum Reads Specifies the minimum number of consecutive times a Code 128 label must be decoded before it is accepted as a good read. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code representing the desired option below or on the following pages. You’ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.
Code 128 Enable Code 128 Minimum Reads — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
EAN-128 Enable Enables/disables the ability of the scanner to decode EAN-128 labels. When disabled, EAN128 labels are transmitted in Code128 data format. When enabled, EAN128 labels are transmitted in EAN128 data format To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
EAN-128 Enable EAN-128 Label ID This feature specifies an EAN-128 label ID to be added to bar code data.. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET EAN-128 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
Interleaved 2 of 5 (I 2 of 5) Enable Enables/disables the ability of the scanner to decode Interleaved 2 of 5 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Interleaved 2 of 5 (I 2 of 5) Enable I 2 of 5 Check Character Calculation Enables/disables calculation and verification of an optional Interleaved 2 of 5 check character. If check character calculation is disabled, the risk is increased that a misread can occur. When disabled, any check characters in a bar code are treated as data characters. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
I 2 of 5 Check Character Transmission Enables/disables transmission of an optional Interleaved 2 of 5 check character. This feature applies only when I 2 of 5 Check Character Calculation is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Interleaved 2 of 5 (I 2 of 5) Enable I 2 of 5 Label ID This feature specifies an I 2 of 5 label ID to be added to bar code data.. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET I 2 of 5 LABEL ID below.
I 2 of 5 Length Control This feature specifies whether variable-length or fixed-length decoding will be set for I 2 of 5. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code. You must now set the features I 2 of 5 Length 1 and I 2 of 5 Length 2.
Interleaved 2 of 5 (I 2 of 5) Enable I 2 of 5 Length 1 Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length mode (see I 2 of 5 Length Control). Length includes the barcode’s check and data characters. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET I 2 of 5 LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
I 2 of 5 Length 2 Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed length mode (see I 2 of 5 Length Control). Length includes the barcode’s check and data characters. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET I 2 of 5 LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Interleaved 2 of 5 (I 2 of 5) Enable I 2 of 5 Correlation This feature enables/disables character correlation for I 2 of 5. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.
I 2 of 5 Stitching Enables/disables stitching for I 2 of 5 labels. When parts of an I 2 of 5 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
Interleaved 2 of 5 (I 2 of 5) Enable I 2 of 5 Minimum Reads Specifies the minimum number of consecutive times an I 2 of 5 label must be decoded before it is accepted as a good read. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code representing the desired option below or on the following pages. You’ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan.
I 2 of 5 Minimum Reads — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Standard 2 of 5 (Std 2 of 5) Enable Standard 2 of 5 (Std 2 of 5) Enable Enables/disables the ability of the scanner to decode Standard 2 of 5 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Standard 2 of 5 Check Character Calculation Enables/disables calculation and verification of an optional Standard 2 of 5 check character. If check character calculation is disabled, the risk is increased that a misread can occur. When disabled, any check characters in a bar code are treated as data characters. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
Standard 2 of 5 (Std 2 of 5) Enable Standard 2 of 5 Check Character Transmission Enables/disables transmission of an optional Standard 2 of 5 check character. This feature applies only when Standard 2 of 5 Check Character Calculation is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Standard 2 of 5 Label ID This feature specifies a Standard 2 of 5 label ID to be added to bar code data.. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET STANDARD 2 of 5 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
Standard 2 of 5 (Std 2 of 5) Enable Standard 2 of 5 Length Control This feature specifies whether variable-length or fixed-length decoding will be set for Standard 2 of 5. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Standard 2 of 5 Length 1 Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length mode (see Standard 2 of 5 Length Control). Length includes the barcode’s check and data characters. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET STANDARD 2 OF 5 LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Standard 2 of 5 (Std 2 of 5) Enable Standard 2 of 5 Length 2 Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed length mode (see Standard 2 of 5 Length Control). Length includes the barcode’s check and data characters. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET STANDARD 2 OF 5 LENGTH 2 below.
Standard 2 of 5 Correlation This feature enables/disables character correlation for Standard 2 of 5. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.
Standard 2 of 5 (Std 2 of 5) Enable Standard 2 of 5 Stitching Enables/disables stitching for Standard 2 of 5 labels. When parts of a Standard 2 of 5 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
Standard 2 of 5 Minimum Reads Specifies the minimum number of consecutive times a Standard 2 of 5 label must be decoded before it is accepted as a good read. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code representing the desired option below or on the following pages. You’ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.
Standard 2 of 5 (Std 2 of 5) Enable Standard 2 of 5 Minimum Reads — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Codabar Enable Enables/disables the ability of the scanner to decode Codabar labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Codabar Enable Codabar Start Stop Character Transmission Enables/disables transmission of Codabar start and stop characters. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Codabar Start Stop Character Set This feature selects the format of transmitted Codabar start/stop characters. Options are: • ABCD/TN* E • ABCD/ABCD • abcd/tn* e • abcd/abcd To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below or from the following page representing the desired option. You’ll need to cover any unused bar codes and facing pages to ensure that the scanner reads only the bar code you intend to scan. 3.
Codabar Enable Codabar Start Stop Character Set — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Codabar Start Stop Character Match Enables/disables the requirement that start and stop characters match. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Codabar Enable Codabar Check Character Calculation Enables/disables calculation and verification of an optional Codabar check character. If check character calculation is disabled, the risk is increased that a misread can occur. When disabled, any check characters in a bar code are treated as data characters. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
Codabar Check Character Transmission Enables/disables transmission of an optional Codabar check character. Applies only when Codabar Check Character Calculation is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Codabar Enable Codabar Label ID This feature specifies a Codabar label ID to e added to bar code data. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODABAR LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
Codabar Require Quiet Zones When enabled, this feature requires that quiet zones (margins) be present for Codabar labels. When disabled, quiet zones are optional. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Codabar Enable Codabar Length Control This feature specifies whether variable-length or fixed-length decoding will be set for Codabar. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Codabar Length 1 Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length mode (see Codabar Length Control). Length includes the barcode’s check and data characters. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODABAR LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Codabar Enable Codabar Length 2 Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed length mode (see Codabar Length Control). Length includes the barcode’s check and data characters. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET STANDARD 2 OF 5 LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Codabar Correlation This feature enables/disables character correlation for Codabar. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.
Codabar Enable Codabar Stitching Enables/disables stitching for Codabar labels. When parts of a Codabar bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
Codabar Minimum Reads Specifies the minimum number of consecutive times a Codabar label must be decoded before it is accepted as a good read. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code representing the desired option below or on the following pages. You’ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.
Codabar Enable Codabar Minimum Reads — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Code 93 Enable Enables/disables the ability of the scanner to decode Code 93 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
Code 93 Enable Code 93 Label ID This feature specifies a Code 93 label ID to be added to bar code data.. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 93 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
Code 93 Length Control This feature specifies whether variable-length or fixed-length decoding will be set for Code 93. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code. You must now set the features Code 93 Length 1 and Code 93 Length 2.
Code 93 Enable Code 93 Length 1 Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length mode (see Code 93 Length Control). Length includes the barcode’s check and data characters. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 93 LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Code 93 Length 2 Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed length mode (see Code 93 Length Control). Length includes the barcode’s check and data characters. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 93 LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
Code 93 Enable Code 93 Correlation This feature enables/disables character correlation for Code 93. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.
Code 93 Stitching Enables/disables stitching for Code 93 labels. When parts of a Code 93 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
Code 93 Enable Code 93 Minimum Reads Specifies the minimum number of consecutive times a Code 93 label must be decoded before it is accepted as a good read. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code representing the desired option below or on the following pages. You’ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.
Code 93 Minimum Reads — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
MSI/Plessey Enable MSI/Plessey Enable Enables/disables the ability of the scanner to decode MSI/Plessey labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
MSI/Plessey Check Character Calculation Enables/disables calculation and verification of optional MSI/Plessey check characters. If check character calculation is disabled, the risk is increased that a misread can occur. When disabled, any check characters in a bar code are treated as data characters. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below.
MSI/Plessey Enable MSI/Plessey Number of Check Characters Specifies number of MSI/Plessey check characters to be calculated and verified. Check characters are always modulus 10. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code below representing the desired number of MSI/ Plessey check characters to be calculated and verified. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
MSI/Plessey Check Character Transmission Enables/disables transmission of optional MSI/Plessey check characters. This feature applies only when MSI/Plessey Check Character Calculation is enabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
MSI/Plessey Enable MSI/Plessey Label ID This feature specifies an MSI/Plessey label ID to be added to bar code data. The programming feature, Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET MSI/PLESSEY LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3.
MSI/Plessey Length Control This feature specifies whether variable-length or fixed-length decoding will be set for MSI/Plessey. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
MSI/Plessey Enable MSI/Plessey Length 1 Length 1 is the minimum label length if in variable length mode, or the first fixed length if in fixed length mode (see MSI/Plessey Length Control). Length includes the barcode’s check and data characters. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET MSI/PLESSEY LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
MSI/Plessey Length 2 Length 2 is the maximum label length if in variable length mode, or the second fixed length if in fixed length mode (see Code 93 Length Control). Length includes the barcode’s check and data characters. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 93 LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3.
MSI/Plessey Enable MSI/Plessey Correlation This feature enables/disables character correlation for MSI/Plessey. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.
MSI/Plessey Stitching Enables/disables stitching for MSI/Plessey labels. When parts of an MSI/ Plessey bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below.
MSI/Plessey Enable MSI/Plessey Minimum Reads Specifies the minimum number of consecutive times an MSI/Plessey label must be decoded before it is accepted as a good read. To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code representing the desired option below or on the following pages. You’ll need to cover any unused bar codes on facing pages to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.
MSI/Plessey Minimum Reads — continued Remember to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Appendix A LED/Beeper Indications & Controls Figure A-1 shows the operator’s controls and indicators. The descriptions following identify the use or function of each component. Figure A-1.
Controls and Indicators The control panel consists of a green LED indicator, a Volume/Tone push button and a Scale Zero push button/LED indicator as described in the following pages. The unit also includes a beeper which can be configured to sound indications of scanning, weighing, and deactivation activities. Since beeper indications are configurable, your unit may not be programmed to sound all the indications listed. For more information, see Chapter 6, Programming in this manual.
Controls and Indicators Table A-1. Scanner and Scale LED Indications LED INDICATION Sleep Mode Indication DURATION Scanner (Green) LED flashes slowly Host Disabled Scanner (Green) LED 1-second off, 1/ 10-second on Audible low tone 1 second. Field Replaceable Unit (FRU) Warning (Error Mode) FRU Indication Alternating Scanner/Scale (Green/ Yellow) LEDs flash continuously. Scanner (Green) LED flashes a coded sequence in concert with the speaker.
Table A-2. Volume/Tone Push Button Functions PRESS DURATION FUNCTION COMMENT Wakes scanner from Sleep Mode Alternatively, the scanner can be awakened by: - Moving an object through the scan zone. - A weight change on the scale. - Scanning with an attached auxiliary scanner. Increments volume Press the push button momentarily to increase speaker volume.
Controls and Indicators Scale Zero Push Button The Scale Zero Push Button is used for multiple functions as listed in Table A-3. The Scale Zero Push Button has no function in a “scanner only” model. NOTE The button must be configured to enable standard functions, or Scale Diagnostics will not be an available feature. Reference Chapter 6, Scanner Button Options for programming details. Table A-3.
Calibration Switch This switch initiates the scale’s calibration routine. A certified weight set is needed to perform the scale calibration steps detailed in Chapter 5, Calibration. This switch is not included in scanners without scale modules. Calibration Switch Seal This seal allows you to secure the Calibration Switch access cover and restrict access to the Calibration Switch. If the calibration seal is broken or missing, you may be prohibited from operating the scale without recertification.
Appendix B Cable Information Introduction The following pages contain pinout information, enabling you to create standard interface cables for use in interconnecting the scanner, scale, external handheld scanner, and POS terminal. General Specifications Wire Requirements • Cable length should not exceed 15 feet. • Wire gauge = Standard for RJ-45 connectors (28-26 AWG). • If run exceeds 15 feet, we recommend 26 AWG wire size.
RS-232 Cable Pinout Scanner Connector Hardware RJ45, 10 Position Cable Pinout Table B-1RS-232 Cable Pinouts B-2 PIN # FUNCTION DESCRIPTION 1 N/C 2 CTS in 3 N/C 4 RTS out Request To Send (output) 5 RxD in Receive Data (Input) 6 TxD out Transmit Data (output) 7 N/C No Connection 8 N/C No Connection 9 GND Signal Ground 10 N/C No Connection No Connection Clear To Send (input) No Connection MagellanTM 8300/8400
Introduction RS-232 Cable Pinout — continued Scale Connector Hardware RJ45, 10 Position Cable Pinout Table B-2RS-232 Scale Cable Pinouts PIN # FUNCTION 1 +5V pullup 2 CTS IN 3 N/C 4 RTS OUT 5 RxD IN Receive Data (Input) 6 TxD OUT Transmit Data (output) 7 N/C No Connection 8 N/C No Connection 9 Gnd Signal Ground 10 N/C No Connection Product Reference Guide DESCRIPTION +5V pullup Clear To Send (input) No Connection Request To Send (output) B-3
IBM Cable Pinout Scanner and Scale Connector Hardware RJ45, 10 Position Cable Pinout Table B-3IBM Cable Pinouts B-4 PIN # FUNCTION DESCRIPTION 1 N/C No Connection 2 N/C No Connection 3 N/C No Connection 4 LINEB 5 N/C 6 LINEA 7 N/C No Connection 8 N/C No Connection 9 GND Signal Ground 10 N/C No Connection Line B No Connection Line A MagellanTM 8300/8400
OEM USB Cable Pinout OEM USB Cable Pinout Scanner and Scale Connector Hardware RJ45, 10 Position Cable Pinout Table B-4.
Auxilliary Port External Handheld Input Connector Hardware RJ45, 10 Position Cable Pinout Table B-5Auxilliary Port Cable Pinouts B-6 PIN # FUNCTION DESCRIPTION 1 +5V pullup 2 CTS in 3 N/C No Connection - Reserved 4 RTS out Request To Send (output) 5 RxD in Receive Data (Input) 6 TxD out Transmit Data (output) 7 N/C 8 +5V out (500mA max) 9 GND Signal Ground 10 N/C No Connection +5V pullup Clear To Send (input) No Connection +5V out MagellanTM 8300/8400
Power Cable Power Cable Connector Hardware 3 pin Molex Cable Pinout Table B-6Power Cable Pinouts PIN # FUNCTION 1 EARTH GND Earth Ground 2 SIGNAL GND Signal Ground 3 +12V IN Product Reference Guide DESCRIPTION +12V in B-7
Remote Display Connector Hardware 4 pin SDL Cable Pinout Table B-7Remote Display Cable Pinouts B-8 PIN # FUNCTION DESCRIPTION 1 +12V OUT 2 LINE_A_DSPLY LINE A Display 3 LINE_B_DSPLY LINE B Display 4 GND +12V out Ground MagellanTM 8300/8400
EAS Comm Port (Sensormatic® systems ON- EAS Comm Port (Sensormatic® systems ONLY) EAS Deactivator Control Box Connection Connector Hardware RJ4 Cable Pinout Table B-8. EAS Port Cable Pinouts PIN # FUNCTION 1 GND 2 +5V Out 3 External Read Indicator 4 Audio Out Product Reference Guide DESCRIPTION GND +5V Out When configured, signifies good read Intended to drive an external amplifier that drives and external speaker.
NOTES B-10 MagellanTM 8300/8400
Appendix C Keypad Use the bar codes in this appendix to enter numbers and characters as you would select digits/characters from a keypad. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Use the bar codes in this appendix to enter numbers and characters as you would select digits/characters from a keypad. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Use the bar codes in this appendix to enter numbers and characters as you would select digits/characters from a keypad. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Use the bar codes in this appendix to enter numbers and characters as you would select digits/characters from a keypad. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Use the bar codes in this appendix to enter numbers and characters as you would select digits/characters from a keypad. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Use the bar codes in this appendix to enter numbers and characters as you would select digits/characters from a keypad. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Use the bar codes in this appendix to enter numbers and characters as you would select digits/characters from a keypad. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Use the bar codes in this appendix to enter numbers and characters as you would select digits/characters from a keypad. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan.
Appendix D Host Commands Accepting Commands from an RS-232 Scanner Host The scanner responds to the following RS-232 commands: COMMAND ASCII HEX COMMENT Enable Scanner E 0x45 Disable Scanner D 0x44 Reset Scanner R 0x52 Not On File Indication F 0x46 Long series of beeps Beep Good Read Tone B 0x42 Beeps if Good Read Beep is enabled Force Good Read Tone 0x01 Beeps regardless of beep setting Bel 0x07 Force Good Read Tone Identification request i 0x69 Returns long responsea Health
NOTES D-2 MagellanTM 8300/8400
Appendix E Keyboard Function Key Mappings Keyboard Model Cross Reference Table E-2 summarizes the keyboard models, their defined protocol, scancode set, and some unique features. The remaining tables in this chapter provide the function key maps associated with each of the scancode sets.
Table E-1. Keyboard Model Cross Reference Model Type PC/XT Foreign ALT Mode AT; PS/2 25-286; PS/2 30-286; PS/2 50, 50Z; PS/2 60,70,80,90,95 Foreign ALT Mode PS/2 25 and 30 Foreign ALT Mode PC/XT U.S. Mode AT; PS/2 25-286; PS/2 30-286; PS/2 50, 50Z; PS/2 60,70,80,90,95 U.S. Mode + specific country support PS/2 25 and 30 U.S. Mode IBM 3xxx Terminals (122-key keyboard) IBM 3xxx Terminals (102-key keyboard) PS55 5530T with JAPANESE DOS (TDOS) NEC 9801 E-2 Wedge A Func.
Keyboard Model Cross Reference Table E-2.
Table E-3.
Keyboard Model Cross Reference Table E-4.
Table E-5.
Keyboard Model Cross Reference Table E-6.
Table E-7.
Keyboard Model Cross Reference Table E-8.
NOTES E-10 MagellanTM 8300/8400
Appendix F Factory Defaults The following table provides a listing of the most common factory settings for the interfaces shown. Table F-1. Factory Default Settings RS-232 WincorNixdorf RS-232 Single Cable Keybd. Wedge IBM OEM USB Enable Std Functions Enable Std Functions Enable Std Functions Enable Std Functions Enable Std Functions Enable Std Functions Double Read Timeout 400ms 400ms 400ms 400ms 400ms 400ms Laser Timeout 5 min. 5 min. 5 min. 5 min. 5 min. 5 min.
RS-232 WincorNixdorf RS-232 Single Cable Keybd.
RS-232 WincorNixdorf RS-232 Single Cable Keybd.
RS-232 WincorNixdorf RS-232 Single Cable 1 stop bit 1 stop bit 1 stop bit None Odd Odd Disable Enable CTS flow None None RS-232 Software Flow Control Disable Disable RS-232 Host Echo Disable Disable RS-232 Host Echo Quiet Interval 10ms 10ms RS-232 Ignore Host Commands Do not ignore Do not ignore RS-232 TTL Normal RS-232 Normal RS-232 RS-232 TTL Invert No invert No invert RS-232 ICL DC1 Character Delay Enable Disable Disable RS-232 Team POS ICL Scale Disable Disable RS-23
RS-232 WincorNixdorf Disable Disable RS-232 ACK Character ACK ACK RS-232 NAK Character NAK NAK RS-232 Retry on ACK NAK Timeout Enable Enable RS-232 ACK NAK Timeout Value 200ms 200ms RS-232 ACK NAK Retry Count 3 resets 3 resets RS-232 ACK NAK Error Handling Ignore errors Ignore errors RS-232 ACK NAK Enable RS-232 Single Cable Single Cable RS-232 Scanner Only Protocol Scannerscale Single Cable RS-232 Stale Weight Timeout 330 msec Single Cable RS-232 Scale — Transmit Weight Digits
RS-232 WincorNixdorf RS-232 Single Cable Single Cable RS-232 Use BCC Disable Single Cable RS-232 Use ACK/NAK Disable Single Cable RS-232 Use STX Enable Set Single Cable RS232 STX Character S Set Single Cable RS232 ETX Character Enable Set Single Cable RS232 ETX Character CR Keyboard Interface — Keyboard Layout US Keyboard Interface Quiet Interval 100 ms Keyboard Interface Caps Lock State Caps lock OFF Keyboard Interface — Keyboard Simulation Disable Keyboard Interface — Control Charac
RS-232 WincorNixdorf RS-232 Single Cable Keybd.
RS-232 WincorNixdorf RS-232 Single Cable Keybd.
RS-232 WincorNixdorf RS-232 Single Cable Keybd.
RS-232 WincorNixdorf RS-232 Single Cable Keybd.
RS-232 WincorNixdorf RS-232 Single Cable Keybd.
RS-232 WincorNixdorf RS-232 Single Cable Keybd.
RS-232 WincorNixdorf RS-232 Single Cable Keybd.
RS-232 WincorNixdorf RS-232 Single Cable Keybd.
RS-232 WincorNixdorf RS-232 Single Cable Keybd.
RS-232 WincorNixdorf RS-232 Single Cable Keybd.
Appendix G Handheld Data Format Requirements This appendix provides application notes to describe the general format of data that can be accepted by the scanner through the auxilliary port as transmitted from a handheld scanner. Handheld Data Format Requirements General • 9600 bps, 8 data bits, 1 stop bit, no parity. • RTS is used to "bracket" the data received from the handheld: RTS must be asserted high during data transmission, and de-asserted after label transmission is complete.
Datalogic Handheld Data Format Requirements The following sections describe label transmission formats that are typically observed in factory configurations of Datalogic handheld scanners. DataBar Omnidirectional • Prefix must be ASCII characters ‘R4’ • Check character must be included in label • Application identifier “01” must follow the prefix and preceed the base label • Label length excluding prefix characters must be 16 characters.
UPC-A with 5-Digit Supplemental • System number must be included in label data • Check digit must be included in label data and is assumed to be correct • Prefix must be an ASCII character 'A' - total length including prefix must be 18 • Example: 'A06099201118712345' UPC-A with Code 128 Supplemental • System number must be included in label data. • Check digit must be included in label data and is assumed to be correct. • Supplemental data is appended to base label.
UPC-E with 2-Digit Supplemental • System number must be included in label data. • Check digit must be included in label data and is assumed to be correct. • Supplemental data is appended to base label. • Prefix must be an ASCII character 'E' - total length including prefix must be 11. • Example: 'E0998875012'. UPC-E with 5-Digit Supplemental • System number must be included in label data. • Check digit must be included in label data and is assumed to be correct.
EAN-8 • Check digit must be included in label data and is assumed to be correct • Prefix must be an ASCII characters 'FF' - total length including prefix must be 10 • Example: 'FF00210126' EAN-8 with 2-Digit Supplemental • Check digit must be included in label data and is assumed to be correct. • Supplemental data is appended to base label. • Prefix must be an ASCII characters 'FF' - total length including prefix must be 12. • Example: 'FF0021012612'.
EAN-13 • Check digit must be included in label data and is assumed to be correct • Prefix must be an ASCII character 'F'- total length including prefix must be 14 • Example: 'F1101234567891' EAN-13 with 2-Digit Supplemental • Check digit must be included in label data and is assumed to be correct • Supplemental data is appended to base label • Prefix must be an ASCII character 'F'- total length including prefix must be 16 • Example: 'F110123456789112' EAN-13 with 5-Digit Supplemental • Check
Code 39 • Check character must be included in label data. • Label length including start, stop and check characters and excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type. • Start and stop characters "*" must be included in label. • Prefix must be an ASCII character '*'. • Example : '**Code 39.TEST*'. Code 39-Pharmacode • Check character must be included in label data.
Standard 2 of 5 • Check character must be included in label data. • Label length including check characters and excluding prefix characters must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type. • Prefix must be an ASCII character 's'. • Example: 's0123456789'. Codabar G-8 • Check character must be included in label data.
Code 128 • Prefix must be an ASCII character '#'. • Label length excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type. • Function characters may be transmitted as a hexadecimal value 8x.
AIM Formats AIM specifies a 3-character string that is attached as a prefix to the label data for transmission. Because AIM specifies one identifier for UPC-A, UPC-E and EAN-13 labels, UPC-A, UPC-E and EAN-13 will be received from the handheld and transmitted to the POS by the scanner as EAN-13. Using this form of identification, the ']' character must be the first character in the label received from the handheld. Further identification of the label is specified in the section below.
• Prefix must be ASCII characters ']E0'- total length including prefix must be 16. • Example: ']E01101234567891'. EAN-8 • Check digit must be included in label data and is assumed to be correct. • Prefix must be ASCII characters ']E4' - total length including prefix must be 11. • Example: ']E400210126'. 2-Digit Supplemental • Supplemental data is appended to any EAN base label. • Prefix must be ASCII characters ']E1'. • length of Supplemental data including prefix must be 5.
5-Digit Supplemental • Supplemental data is appended to any EAN base label. • Prefix must be ASCII characters ']E2'. • Length of supplemental data including prefix must be 8. Total required length is 24 for EAN-13 and 19 for EAN-8. • Prefix for the main body portion of the label for UPCA/UPCE/ EAN13 can be ]E0 or ]E3. • If the main body prefix for UPCA/UPCE/EAN13 is ]E0, then the 5-digit addon portion of the label must have a prefix of ]E2.
Code 39 • Check character must be included in label data. • Label length including start, stop and check characters and excluding prefix characters must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type. • Start and stop characters "*" must be included in label. • Prefix must be ASCII characters ']A0' or ']A1'. • Example: '*]A0Code 39.TEST*'. Codabar • Check character must be included in label data.
Code 93 • Prefix must be ASCII characters ']G0'. • Label length excluding prefix characters must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type. • Example : ']G0Code93-test'. DataBar Omnidirectional • Prefix must be ASCII characters ']e0'. • Check character must be included in label. • Label length excluding prefix characters must be 14 characters. • Example: ']e001044123456789'.
Standard 2 of 5 • Check character must be included in label data. • Label length including check characters and excluding prefix characters must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type. • Prefix must be an ASCII character ']S0' (other prefixes specify different check character properties which are not supported). • Example: ']S00123456789'. Code 128 / EAN128 • Prefix must be either ASCII characters ']C0', ']C1' or ']C2'.
NOTES G-16 MagellanTM 8300/8400
ASCII Character Set The table on this page shows a set of ASCII characters and their corresponding Hex Values. The Hex Values in this table are needed for setting symbology specific label identifiers, as well as enabling custom prefix and suffix characters. ASCII / Hex Conversion Table ASCIIChar. Hex No. ASCIIChar. Hex No. ASCIIChar. Hex No. ASCIIChar. Hex No.
Australia Japan Datalogic Scanning Pty Ltd Telephone: [61] (2) 9870 3200 australia.scanning@datalogic.com Datalogic Scanning KK Telephone: 81 (0)3 3491 6761 japan.scanning@datalogic.com France and Benelux Latin America Datalogic Scanning SAS Telephone: [33].01.64.86.71.00 france.scanning@datalogic.com Datalogic Scanning, Inc Telephone: (305) 591-3222 latinamerica.scanning@datalogic.com Germany Singapore Datalogic Scanning GmbH Telephone: 49 (0) 61 51/93 58-0 germany.scanning@datalogic.