Specifications

Product Reference Guide G-13
Code 39
Check character must be included in label data.
Label length including start, stop and check characters and exclud-
ing prefix characters must meet requirements imposed by the main
scanner's fixed or variable label length control for this symbology
type.
Start and stop characters "*" must be included in label.
Prefix must be ASCII characters ']A0' or ']A1'.
Example: '*]A0Code 39.TEST*'.
Codabar
Check character must be included in label data.
Label length including check character and excluding prefix charac-
ters must meet requirements imposed by the main scanner's fixed or
variable label length control for this symbology type.
Prefix must be ASCII characters ']F0'.
Start stop character sets must meet the matching requirement set
forth by the scanner configuration item
Codabar Start Stop Character
Match
.
Start stop character sets s must be of the form ABCD/ABCD and
must be included in the label.
Example: ']F0s$99.95s' (the lower case ‘s’ at each end of the example
is a placeholder for the start stop character set).
MSI/Plessey
Check character must be included in label data.
Label length including check character and excluding prefix charac-
ters must meet requirements imposed by the main scanner's fixed or
variable label length control for this symbology type.
Prefix must be ASCII characters ']M0'.
Example: ']M0144769254'.