MagellanTM 9800i Scanner and Scanner-Scale with Imaging Technology Quick Reference Guide
Datalogic ADC, Inc. 959 Terry Street Eugene, OR 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 ©2012 - 2013 Datalogic, Inc. An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic ADC, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic ADC”).
DATALOGIC ADC, INC. MAGELLANTM END USER LICENSE AGREEMENT Notice to End User: The Datalogic Product you have acquired contains embedded Software, which is integral to the product's operation. This Software is being provided to you under license, subject to the terms and conditions of this Agreement. If you use the Datalogic Product, you will be deemed to have accepted the terms and conditions of this Agreement.
6.2 requested information and assistance necessary to help Datalogic in remedying such nonconformities. For all defects reported to Datalogic within the warranty period, Datalogic's liability is limited to providing End User with one copy of corrections or responding to End User's problem reports according to Datalogic's standard assistance practices.
Introduction The MagellanTM 9800i is a multi-plane imaging bar code scanner with an optional integrated scale, designed to serve in supermarket peripheral lanes. This manual describes its basic operation. For more detailed information about setup, installation and programming, see the Product Reference Guide for this product. These manuals are provided in Portable Document Format (PDF) for viewing and printing from the website listed on the back cover of this manual.
Power Supply The scanner requires the use of an external power adapter. Use only Datalogic-approved power supplies. See the Product Reference Guide (PRG) for more information. Alternately, scanners connected via USB can receive Power Off the Terminal (P.O.T.) if it is determined the terminal can supply adequate power to the scanner in this manner. Características de la fuente de alimentación eléctrica. Atención Entrada: 100 - 240 Vca @ 800mA 50/60 Hz Salida: +12 VDC @ 2500mA.
Certification Label At the time the local scale regulatory authority certifies the scanner/scale for use, a certification label is affixed to the unit. Depending upon the size and shape of the label, placement can be made in one of the locations shown in Figure 1. Figure 1.
Scanning Items Slide or push items through the SurroundScanTM scan zone in a right-to-left or left-to-right movement. The scanner is equally efficient at scanning items in either direction. It is unnecessary to shift the position of the bar code, as the scanner can “read” it from the bottom, top, left, right, front and back side of an item, as long as it is fully within the scan zone. Figure 2.
The SurroundScan™ scan pattern and advanced FirstStrike™ decoding software ensures the scanner will read most hard-to-read codes quickly and without a need to particularly reorient items. Weighing Items (Scale Models) The unique platter design allows you to place items anywhere on its surface, including leaning atop its vertical section, to be weighed accurately. In addition, the Produce RailTM allows items to rest above the counter and other non-weighing surfaces. See Figure 3.
Top Down Reader (TDR) Option The scanner’s exclusive Top Down Reader (TDR) is an optional feature of the scanner, and is available in two different heights in order to provide flexibility for installations. The TDR can perform multiple functions: • The TDR contributes significantly to the overall bar code read zone by scanning items from a unique top-down angle. • The eCommerce option allows customers to use the TDR to conveniently scan coupons and other bar codes presented ...
Electronic Article Survellance (EAS) Deactivation Options Deactivation of Sensormatic® or Checkpoint® EAS tags is an optional function. The scanner must be expressly enabled to perform in either capacity. Sensormatic Coupled Mode When the scanner is configured to use Coupled EAS Deactivation Mode, deactivation of a given item happens automatically following its bar code being successfully read.
Figure 6. Control Buttons and Indicator LEDs 4 1 8 5 2 9 6 7 3 1 Scale Zero Button 6 With all weight removed from the scale, push this button to set the scale to zero. 2 Manual EAS Deactivation Button ScaleSentryOverride Button 7 Scale Indicator LED (Yellow) 8 EAS Indicator LED (Red/Green/ Orange) This LED indicates EAS functions with red, green OR orange color. See the Indicator Table for more information.
WEEE Statement Waste Electrical and Electronic Equipment (WEEE) Statement English For information about the disposal of Waste Electrical and Electronic Equipment (WEEE), please refer to the website at www.datalogic.com. Italian Per informazioni sullo smaltimento delle apparecchiature elettriche ed elettroniche consultare il sito Web www.datalogic.com. French Pour toute information relative à l’élimination des déchets électroniques (WEEE), veuillez consulter le site internet www.datalogic.com.
10 O X X 电 子 称 组 件 电 子 秤 支 架 组 件 多氯联苯的程序集 显 示 器 组 件 终 端 断 电 组 件 规模哨兵大会 Scale Assembly Assembly, Spider PCB Assemblies Assembly Remote display Power Off Terminal Assembly Scale Sentry assembly O X Hexavalent Chromium (Cr(VI)) Polybrominated biphenyls (PBB) O O O O O O O 镉 O O O O O O O 六价铬 O O O O O O O 多溴联苯 有毒有害物质或元素 Cadmium (Cd) O O O O O O O 多溴二苯醚 Polybrominated diphenyl ethers (PBDE) O: 代表此种部件的所有均质材料中所含的该种有毒有害物质均低于中华人民共和国信息产业部所颁布的 《电子信息产品中有毒有害物质的限量要求》(SJ/T
LED and Beeper Indications The scanner’s beeper sounds and its lamps and indicator LEDs illuminate to indicate various functions or errors. The tables in this section list some of these indications. Reference the PRG for a more complete listing. One exception to the behaviors listed in the tables is that some functions are programmable, and may or may not be turned on. For example, certain indications such as the power-up beep can be disabled using programming bar code labels.
Error Codes Upon startup, if the scanner sounds a long error tone followed by alternating flashing of the green and yellow LED indicators, and an error code is displayed on the Health & Status Indicator, this means the scanner has not passed its automatic Selftest and has entered FRU (Field Replaceable Unit) isolation mode. The scanner remains in this mode, until any button is pushed.
Product Labeling The illustration on the following page shows the general shape and position of the labels located on the scanner beneath the platter and on the bottom side of the scanner. Labels are shown to illustrate their location only. Please view the labels on your product for actual details.
1 2 3 0.00 AUX SCALE HOST EAS 4 TDR 0.
Warranty Datalogic warrants to Customer that this product will be free from defects in materials and workmanship for a period of 1 year from product shipment. Datalogic ADC Limited Factory Warranty Warranty Coverage Datalogic ADC (“Datalogic”) hardware products are warranted against defects in material and workmanship under normal and proper use.
Warranty Claims Process In order to obtain service under the Factory Warranty, Customer must notify Datalogic of the claimed defect before the expiration of the applicable Warranty period and obtain from Datalogic a return authorization number (RMA) for return of the product to a designated Datalogic service center. If Datalogic determines Customer’s claim is valid, Datalogic will repair or replace product without additional charge for parts and labor.
(v) any defect or damage caused by natural or man-made disaster such as but not limited to fire, water damage, floods, other natural disasters, vandalism or abusive events that would cause internal and external component damage or destruction of the whole unit, consumable items; (vi) any damage or malfunctioning caused by non-restoring action as for example firmware or software upgrades, software or hardware reconfigurations etc.
Risk of Loss Customer shall bear risk of loss or damage for product in transit to Datalogic. Datalogic shall assume risk of loss or damage for product in Datalogic’s possession. In the absence of specific written instructions for the return of product to Customer, Datalogic will select the carrier, but Datalogic shall not thereby assume any liability in connection with the return shipment.
DECLARATION OF CONFORMITY EC-80 Rev.: 1 Pag.: 1 di 1 Datalogic ADC, Inc. 959 Terry Street Eugene, Oregon 97402 USA 12 La presente dichiarazione di conformità è rilasciata sotto la responsabilità esclusiva di Datalogic ADC, Inc. per: This Declaration of Conformity is issued under the sole responsibility of Datalogic ADC, Inc.
www.datalogic.com © 2012-2013 Datalogic ADC, Inc. • All rights reserved. • Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. Datalogic ADC, Inc. 959 Terry Street | Eugene |OR 97402 | USA Telephone: (1) 541-683-5700 | Fax: (1) 541-345-7140 820056714 (Rev.