PowerScan™ BT8300 Family Industrial Handheld Bar Code Reader with Bluetooth® Wireless Technology Quick Reference Guide
Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”).
Table of Contents Using the PowerScan™ BT8300....................................................................... 3 Scan Line Position ......................................................................................... 3 Reading Angle ................................................................................................ 3 Aiming System ............................................................................................... 4 Installing the Battery Pack.............................
Laser Safety Compliance .......................................................................... 24 LED CLASS ..................................................................................................... 25 IC (Industry Canada) ................................................................................... 25 WEEE Compliance ....................................................................................... 26 Hex/Numeric Table ..............................................................
PowerScan™ BT8300 Reader Using the PowerScan™ BT8300 The PowerScan™ BT8300 family of readers can be used with either the PowerScan BC 8030-BT base station or a Bluetooth-enabled PC to build a Cordless Reading System for the collection, decoding and transmission of bar coded data. PowerScan™ BT8300 laser readers automatically scan bar codes at a distance. Simply aim and pull the trigger. Scan Line Position Code scanning is performed along the scan line emitted from the reading window.
Using the PowerScan™ BT8300 Aiming System PowerScan™ BT8300 provides an aiming system. If enabled, a partial trigger press produces a red spot, which should be aimed over the code center to get the best reading performance, see (1) in the figure above. By completely pressing the trigger the scan line appears to start the code scanning, see (2).
Installing the Battery Pack Installing the Battery Pack To install, charge and/or do any other action on the battery, follow the instructions in this manual. To charge the Battery Pack, See “Charging the Batteries” on page 7. Datalogic recommends annual replacement of rechargeable battery packs to ensure maximum performance. WARNING Do not discharge the battery using any device except for the scanner.
Installing the Battery Pack CAUTION Always charge the battery at 32° – 113°F (0° - 45°C) temperature range. Use only the authorized power supplies, battery pack, chargers, and docks supplied by your Datalogic reseller. The use of any other power supplies can damage the device and void your warranty. Do not disassemble or modify the battery. The battery contains safety and protection devices, which, if damaged, may cause the battery to generate heat, explode or ignite.
Installing the Battery Pack Charging the Batteries Once the BC 8030-BT/C-8000 is powered, you can charge the reader's batteries. Place the PowerScan™ BT8300 into the BC 8030-BT cradle or the C-8000 battery charger. The Reader LED on the cradle/battery charger turns red. The battery is completely charged when the Reader LED on the cradle/battery charger turns green. Figure 1. Changing the Batteries 1 2 WARNING Do not incinerate, disassemble, short terminals or expose to high temperature.
Setup Setup Restore PowerScan BT 8300 Default Before starting configuration and every time you want to restore factory settings, read the label below. Please note that the default mode on PowerScan BT8300 is Handheld - Cradle communication: Restore PowerScan BT 8300 Default Date and Time Setup Scan the following bar codes in sequence to set the date and time for the PowerScan BT8300. Enter Configuration 1. Set Date 2. 3. + Six digits for Day, Month and Year (DDMMYY) Set Time 4. 5.
Connecting the PowerScan BT8300 Connecting the PowerScan BT8300 Overview PowerScan™ BT8300/BC 8030-BT Configuration 1. 2. 3. 4. Connect a BC 8030-BT cradle to the Host. For installation and connection information see the BC 8030-BT Quick Reference Guide. Charge the PowerScan BT8300 battery using a BC 8030-BT, the CHR-PM80 or BC-P080 chargers as described in this Quick Reference Guide.
Connecting the PowerScan BT8300 Before You Begin In order to use the connection procedures below, the handheld and base station must be in an UNPAIRED state. If the reader is connected to a device, you must follow the procedure below to UNPAIR the Base Station and the handheld before attempting to link to a new device. If the handheld is not already connected to another device, then you can skip this step and go straight to the Linking instructions that begin on the next page.
Connecting the PowerScan BT8300 Link by Contact Read the bar codes in sequence as shown in the steps below: Enter Configuration 1. Handheld - Cradle 2. Link by Contact 3. Exit and Save Configuration 4. 5. Firmly position the reader onto the cradle. The BC 8030-BT cradle will emit a beep and the yellow LED will blink while the cradle is trying to establish the connection.
Connecting the PowerScan BT8300 Link by Inquiry Enter Configuration 1. Handheld - Cradle 2. Exit and Save Configuration 3. 4. To connect another PowerScan PBT8300 to the BC 8030-BT cradle, repeat in the sequence from steps 1 through 3 before continuing. One Cradle can connect with a maximum of four readers. 5. Quickly press the button (<8 seconds and release) on the BC 8030-BT cradle. The yellow LED on the cradle will blink and it will search for any PowerScan BT 8300 readers in radio range.
Connecting the PowerScan BT8300 Linking the PowerScan BT8300 to a Bluetooth-Enabled PC The PowerScan BT8300 reader can optionally be linked to a Bluetooth-enabled host with the serial port profile (SPP) or human interface device (HID) as a virtual keyboard. Depending on the driver used by your device, specific actions may be required the first time a connection is made between the PowerScan PBT8300 and a generic Bluetooth peripheral.
Connecting the PowerScan BT8300 Linking to a PC in Serial Port Profile (Master) Mode To link a PowerScan BT8300 reader in Serial Port Profile (Master) Mode to a Bluetooth-enabled host, follow the instructions below and read the bar codes in the given sequence. 1. Select the "COM Ports" tab on the Window's Bluetooth Manager and add the Incoming Port. You will receive a notification that the Incoming Port is added successfully. 2.
Connecting the PowerScan BT8300 Linking to a PC in HID To link a PowerScan BT8300 reader in HID to a Bluetooth-enabled PC, please read the following bar codes in the given sequence: Enter Configuration 1. HID Profile 2. Exit and Save Configuration 3. 4. Use the host computer's Bluetooth Manager to "Add Bluetooth Device Wizard" and select "PowerScan BT8300.
Connecting the PowerScan BT8300 PowerScan BT8300 HID Configuration HID Country Codes *Country Code = U.
Connecting the PowerScan BT8300 HID Country Codes (cont.
Connecting the PowerScan BT8300 HID Country Codes (cont.
Connecting the PowerScan BT8300 Caps Lock State This option specifies the format in which the reader sends character data.
PowerScan™ BT8300 Default Configuration PowerScan™ BT8300 Default Configuration DATA FORMAT Code identifier disabled, Field adjustment disabled, Code length not transmitted, Character replacement disabled CODE SELECTION Enabled Codes • EAN 8/EAN 13 / UPC A/UPC E without ADD ON Check digit transmitted, no conversions • Interleaved 2/5 Check digit control and transmission, variable length code; 4-99 characters • Standard Code 39 No check digit control, variable length code; 1-99 characters • Code 128 variab
Technical Features Technical Features Electrical Features Battery Type 2150 Li-Ion battery pack Time of recharge max. 4 hours with external power supply max. 10 hours with Host power Operating autonomy (continuous reading) 50,000 reads (typical) Display LCD 4 lines x 16 chars Programmable LED backlight Indicators Good Read LED green; Good Read Spot green; Beeper Laser Features BT8300 BT8300-AR Power (max) in mW 0.9 mW 1.
Reading Distance Reading Distance PowerScan™ BT8300 mil Typical reading distance with good quality codes 5 2.1 - 13.3 cm / 0.8 - 5.2 in 7,5 3.5 - 24.2 cm / 1.4 - 9.5 in 10 2.9 - 42.8 cm / 1.1 - 16.8 in 13 2.3 - 55.1 cm / 0.9 - 21.7 in 20 6.3 - 78.5 cm / 2.5 - 30.9 in 40 2.5 - 97.8 cm / 1.0 - 38.5 in PowerScan™ BT8300 AR mil Typical reading distance with good quality codes 7,5 18 - 50 cm / 7.0 - 19.7 in 10 18 - 85 cm / 7.0 - 33.5 in 15 15 - 165 cm / 5.9 - 65.0 in 20 12 - 210 cm / 4.
Warranty Warranty Datalogic warranties this product against defects in workmanship and materials, for a period of 3 years from the date of shipment, provided that the product is operated under normal and proper conditions. Datalogic has the faculty to repair or replace the product; these provisions do not prolong the original warranty term. The warranty does not apply to any product that has been subject to misuse, accidental damage, unauthorized repair or tampering.
Compliance Compliance This device must be opened by qualified personnel only. The batteries must be removed before opening the device. FCC Compliance Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment. This device complies with PART 15 of the FCC Rules.
Compliance La utilización de procedimientos o regulaciones diferentes de aquellas describidas en la documentación puede causar una exposición peligrosa a la luz láser visible. CAUTION The laser scanner utilizes a low-power laser diode. Although staring directly at the laser beam momentarily causes no known biological damage, avoid staring at the beam as one would with any very strong light source, such as the sun.
Compliance WEEE Compliance Waste Electrical and Electronic Equipment (WEEE) Statement English For information about the disposal of Waste Electrical and Electronic Equipment (WEEE), please refer to the website at www.scanning.datalogic.com. Italian Per informazioni sullo smaltimento delle apparecchiature elettriche ed elettroniche consultare il sito Web www.scanning.datalogic.com.
Hex/Numeric Table Hex/Numeric Table Ì01Î 0 Ì12Î 1 Ì23Î 2 Ì34Î 3 Ì45Î 4 Ì56Î 5 Ì67Î 6 Ì78Î 7 Ì89Î 8 Ì9:Î 9 Quick Reference Guide 27
Hex/Numeric Table Hex/ Numeric Table (continued) A B C D E F Cancels an incomplete configuration sequence Exit and Save Configuration 28 PowerScan™ BT8300
Datalogic Scanning, Inc.
Australia Datalogic Scanning Pty Ltd Telephone: [61] (2) 9870 3200 australia.scanning@datalogic.com Japan Datalogic Scanning KK Telephone: 81 (0)3 3491 6761 japan.scanning@datalogic.com France and Benelux Datalogic Scanning SAS Telephone: [33].01.64.86.71.00 france.scanning@datalogic.com Latin America Datalogic Scanning, Inc Telephone: (305) 591-3222 latinamerica.scanning@datalogic.com Germany Datalogic Scanning GmbH Telephone: 49 (0) 61 51/93 58-0 germany.scanning@datalogic.