User Manual

Enter/Exit Programming Mode
170
PowerScan™ PD9530/PBT9500/PM9500
Plessey Set Length 1
This feature specifies one of the bar code lengths for Plessey Length Con-
trol. Length 1 is the minimum label length if in Variable Length Mode, or the
first fixed length if in Fixed Length Mode. Length includes
the bar code’s
data characters only. The length can be set
from 01 to 50 characters.
Table 24 provides some examples for setting Length 1. See page 283 for
detailed instructions on setting this feature.
Table 24. Plessey Length 1 Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
01 Characters 07 Characters 15 Characters 50 Characters
2 Scan ENTER/EXIT PROGRAMMING MODE
3 Scan SELECT Plessey LENGTH 1 SETTING
4
Scan Two Characters From
Appendix D, Keypad
‘0’ and ‘1’ ‘0’ and ‘7’ ‘1’ and ‘5’ ‘5’ AND ‘0’
5 Scan ENTER/EXIT PROGRAMMING MODE
$CPLL1
Select Plessey Set Length 1 Setting
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
~
CANCEL
DEFAULT
01 = Length 1 is 1 Character