User Manual

Enter/Exit Programming Mode
248
PowerScan™ PD9530/PBT9500/PM9500
Display Off Timeout
Sets the timeout for display, backlight and keyboard.
Display Off Timeout = Disabled
$CDIOT
Set Display Off Timeout
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at
le
ft followed by two digits from the Alphanumeric
characters in
Appendix D, Keypad
representing
your desired character(s). End by scanning the ENTER/
EXIT bar
code again.
Make a mistake? Scan the CANCEL bar code to abort
and no
t save the entry string. You can then start again
at the beginning.
~
CANCEL
DEFAULT
08 = 8 second delay
Backlight Enable
Enables/Disables the display backlight.
DEFAULT
$CDIBL00\r
Backlight Disabled
$CDIBL01\r
Backlight Enabled