User Manual

Enter/Exit Programming Mode
250
PowerScan™ PD9530/PBT9500/PM9500
Enable/disable buttons
This feature offers the ability to enable or disable the keypad.
Figure 6. PowerScan 9500 Keypad Models
16-key keypad
4-key keypad
Key Programming
$CPWFZFFFF\r
All keys enabled
DEFAULT
$CPWFZ0000\r
All keys disabled
$CPWFZ
Enable a combination of keys (4-key models only)
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar code at
le
ft followed by 4 digits from the Alphanumeric charac-
ters in
Appendix D, Keypad
.
4-key models only
: The last 3 digits must always be 0;
the 4 bits of the first digit must be 1 if the corresponding
key is enabled; the four bits represent, starting from the
highest: Arrow Up, F2, F1, Arrow Down. End by scanning
the ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort and
not save the ent
ry string. You can then start again at the
beginning.
~
CANCEL