User Manual

Setup
18
PowerScan™ PD9530/PBT9500/PM9500
Resetting the Product Configuration to Defaults
Restore Custom Defaults
If you aren’t sure what programming options are in your imager, or you’ve
changed some options and want to restore the Custom Default Configura-
tion that may have been saved in the scanner, scan the Restore Custom
De
fault Configuration bar code below. This will restore the custom configu-
ration for the currently active interface.
Restore Custom Default Configuration
$P,HA00,P(CR)
Custom defaults are based on the interface type. Configure the
imager for the correct interface before scanning this label.
Restore Factory Configuration
The "Restore Custom Default Configuration" command above is normally
enough to restart the machine from a known status (set in the factory or by
the customer via configuration file). The machine is set as it arrived to you
from the factory or according to the custom configuration file you loaded
afterward.
If you want to
permanently cancel the setup defined by the configuration
file use "Restore Factory Configuration" on page 338 of this manual.
The programming items listed in the following sections show the factory
d
efault settings for each of the menu commands. If no configuration file has
been loaded, the above command restores the factory default.
Set Date and Time
1. Scan the Enter/Exit Programming bar code below to set date and time.
ENTER/EXIT PROGRAMMING MODE
2. Scan the Set Date bar code + six
digits for Year, Month and Day
(YYMMDD) from Appendix D,
Keypad.
Set Date
Set Time
3. Scan Set Time + six digits for
Hours, Minutes and Seconds
(HHMMSS) from Appendix D,
Keypad.
4. Scan the Enter/Exit Programming bar code to complete.