Australia Japan Datalogic Scanning Pty Ltd North Ryde, Australia Telephone: [61] (2) 9870 3200 Fax: [61] (2) 9878 8688 Datalogic Scanning KK Shinagawa, Tokyo, Japan Telephone: 81 (0)3 3491 6761 Fax: 81 (0)3 3491 6656 France and Benelux Latin America Datalogic Scanning Sarl LES ULIS Cedex, France Telephone: [33].01.64.86.71.00 Fax: [33].01.64 46.72.
Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”).
CONTENTS Updates and Language Availability .................................................................................... iv PowerScan® D8530 family Description ................................................................................1 Using PowerScan® D8530 family .......................................................................................2 Indicators ............................................................................................................................3 Setup .
UPDATES AND LANGUAGE AVAILABILITY UK/US The latest drivers and documentation updates for this product are available on Internet. Log on to: www.scanning.datalogic.com I Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto. Questo manuale è disponibile anche nella versione italiana. Collegarsi a: www.scanning.datalogic.com F Les versions mises à jour de drivers et documentation de ce produit sont disponibles sur Internet.
POWERSCAN® D8530 FAMILY POWERSCAN® D8530 FAMILY DESCRIPTION The present manual includes just a few commands to allow the startup of the scanner and setting of the required interface. For complete configuration of the scanner, refer to the PowerScan D8530 Reference Manual or the Aladdin configuration program, both downloadable from the website and available on the included CD ROM. The PowerScan® D8530 Hand-Held Reader packs a lot of performance into an attractive, rugged, hand-held device.
DATALOGIC USING POWERSCAN® D8530 FAMILY PowerScan® D8530 normally functions by capturing and decoding codes. The PowerScan® D8530 reader uses an intelligent aiming system. By pulling the trigger, the aiming system indicates a field of view, which should be positioned over the code: Aiming System When you pull the trigger, a red beam illuminates the code. If the aiming system is centered and the entire symbology is within the aiming system, you will get a good read.
POWERSCAN® D8530 FAMILY INDICATORS LED INDICATORS The PowerScan® D8530 family uses green LED indicators to signal the following reader functions: STATUS BEHAVIOR Power ON At power-on, the LEDs blink briefly, then light up for 2 seconds to signal the power supply is present. Normal Function The LED lights up after a good decoding and will switch off only at the next trigger press. BEEPER The PowerScan® D8530 basic software provides beeper signals for good/wrong reading and for indicating errors.
DATALOGIC CONNECTIONS CONNECTING THE CABLE A. B. C. D. E. Rubber gasket Plastic boot Cable spacer Cover Strain relief Align c Slip the cover over the cable. d Push the plastic boot into the rubber gasket. Take care that the tab on the plastic boot is aligned with the notch in the rubber gasket. e Push the plastic boot and gasket into the handle. Ensure that the “Front” marking on the plastic boot is facing out, with the arrow pointing towards the front of the scanner.
POWERSCAN® D8530 FAMILY RS-232 WEDGE USB The USB interface is compatible with: ® Windows 98 (and later) Mac OS 8.
DATALOGIC START-UP As with all USB devices, upon connection, the Host performs several checks by communicating with the PowerScan® D8530™. During this phase the green LED on the PowerScan® D8530™ reader blinks and normal operations are suspended.
POWERSCAN® D8530 FAMILY INTERFACE SELECTION RS-232 WEDGE – IBM AT AMHKHMFOHNGNENEIEPANHOGOCK AGPEPJAMDKEOFMHMLJAKFEHFKK AMGNPJCJGIIJCMCEGJMHNDOLLK AIFBJLBGMHPLNKECPCGMBBIBOK AAPHBAJJDAAGMGKDDAOHBGGLHK AEKFBONJCDDIECLFJIJKMCHLIK DLDDLDLDLLDLLLLDLLDDDLDLLL AMHKHMFOHNGNENEIEPANHOGOCK AGPEPJAMDKEOFMHMLJALFAEHKK AEONPJCJGIIJCMCEHPLLHLPPJK AIFBJLBGMHPLNPDFHGDGFIBDOK AAPHBAJJCGCOPJDIMBCEANODDK AFKFBPPJPJCAALOIKIECIPIKLK DDLDLDLDDLDLLLLDDDDDDLDLDL USB BULK USB KB EMULATION AMHKHMFOHNGNENEIEPANHOGOCK AGPEPJAM
DATALOGIC WEDGE KEYBOARD NATIONALITY This parameter default value is restored through the Interface Selection code and not through the Restore Default code. Select one of the following keyboard nationality codes.
POWERSCAN® D8530 FAMILY USB KEYBOARD NATIONALITY This parameter default value is restored through the Interface Selection code and not through the Restore Default code. Select one of the following keyboard nationality codes.
DATALOGIC READING PARAMETERS GOOD READ SPOT DURATION Disabled AMHKHNGMFNGNENEIEPANHOGOCK AGPEPBIMDKEOFMHMLJAKEEGEKK AMGNPJCJGIIJCMCEHMNEPKCDPK AIFBJLBGMHPLNKHNAEHPNLGDOK AAPHBAJIDFDNGNPJFBDBHFOHHK AHLFBOIEEHIOMFIGJFGGIFJKKK DDDDLDLDDDLLLLLDDLDDDLDLLL ♦ Short AMHKHNGMFNGNENEIEPANHOGOCK AGPEPBIMDKEOFMHMLJALEAFGKK AEONPJCJGIIJCMCEGKKIFCDHNK AIFBJLBGMHPLNPAKIACFJCPBOK AAPHBAJICDBFFCGCKAPCGOGPDK AGLFBPKEJNJGIMNLKFLOMIGLJK DLLDLDLDLDLLLLLDLDDDDLDLDL Medium Long AMHKHNGMFNGNENEIEPANHOGOCK AGPEPBIMDKEOFMHMLJAK
POWERSCAN® D8530 FAMILY DEFAULT CONFIGURATION RS-232 Standard DEFAULT SETTINGS 115200 baud, no parity, 8 data bits, 1 stop bit, no handshake, no protocol, FIFO enabled, intercharacter delay = 0, intercode delay = 0, serial trigger lock disabled, serial trigger lock disable character = NUL, serial trigger lock enable character = NUL, RX Timeout = 10 sec USB COM Emulation DEFAULT SETTINGS no handshake, no protocol, FIFO enabled, intercharacter delay = 0, intercode delay = 0 USB Keyboard Emulation DEFAULT SE
DATALOGIC CODE SELECTION issue identical codes = enable enabled codes Standard Code 39: no check digit control, variable code length; EAN 8/EAN 13 / UPC A/UPC E without ADD ON: UPCE expansion disabled Interleaved 2/5: check digit control and transmission, variable code length Code 128: variable code length PDF417 Datamatrix: rectangular, normal and inverted, variable code length QR disabled codes Code 32, Codabar, Code 93, EAN 128, Aztec, GS1 DataBar™, Micro PDF417, Postal Codes, Maxicode, Composite Codes
POWERSCAN® D8530 FAMILY OPERATING TEST EAN-13 Code 39 (Standard) 1 234567 000992 Code 128 t e s QR 1 7 1 6 2 PDF417 t Data Matrix (Normal) 13
DATALOGIC TECHNICAL FEATURES PowerScan® D8530 Family Common Features Electrical Features Operating Voltage 5 to 30 V Power Consumption @ 5V (Typical) 600 mA @30V (Typical) 100 mA Communications Features RS-232, Keyboard emulation AT IBM, USB COM Standard Interfaces Proprietary Interfaces Environmental Features Operating Temperature Storage Temperature Humidity Drop Resistance IP Sealing emulation, USB Keyboard emulation USB Bulk, USB Generic HID -10° to +55° C (+14° to +131° F) -20° to +70° C (-4° to +15
POWERSCAN® D8530 FAMILY PowerScan® D8530™ Optical Features Focus distance 140 mm Field of view 28° (H) x 23° (V) Horizontal field of view at 0.52d + 15 distance (d) in mm Vertical field of view at 0.42d + 12 distance (d) in mm Max Resolution Linear codes PDF 417 – Datamatrix – mm (mils) mm (mils) mm (mils) 0.10 (4 mils) 0.10 (4 mils) 0.17 (6.6 mils) Depth of field* 1D (linear): X-dimension DOF mm (mils) cm (in) Code39 0.13 (5) 7.5 to 15.5 (2.95 to 6.10) 0.5 (20) 5.5 to 36.5 (2.17 to 14.37) EAN13 0.
DATALOGIC PowerScan® D8530™ HD Optical Features Focus distance Field of view Horizontal field of view at distance (d) in mm Vertical field of view at distance (d) in mm Max Resolution 65 mm 27° (H) x 22° (V) 0.50d + 13 0.40d + 10 Linear codes mm (mils) 0.05 (2 mils) PDF 417 – mm (mils) 0.08 (3 mils) Datamatrix – mm (mils) 0.10 (4 mils) Depth of field* 1D (linear): Code39 EAN13 2D: PDF417 X-dimension mm (mils) 0.08 (3) 0.13 (5) 0.51 (20) 0.33 (13) X-dimension mm (mils) 0.08 (3) 0.13 (5) 0.
POWERSCAN® D8530 FAMILY PowerScan® D8530™ WA Optical Features Focus distance Field of view Horizontal field of view at distance (d) in mm Vertical field of view at distance (d) in mm Max Resolution 115 mm 54° (H) x 45° (V) 1.04d + 40 0.40d + 10 Linear codes mm (mils) 0.13 (5 mils) PDF 417 – mm (mils) 0.13 (5 mils) Datamatrix – mm (mils) 0.19 (7.5 mils) Depth of field* 1D (linear): Code39 X-dimension mm (mils) 0.13 (5) DOF cm (in) 2.5 to 10.0 (0.98 to 3.94) 1.5 to 32 (0.59 to 12.60) 1.5 to 26.0 (0.
DATALOGIC SERVICE AND SUPPORT Datalogic provides several services as well as technical support through its website. Log on to www.scanning.datalogic.com and click on the links indicated for further information including: • PRODUCTS Search through the links to arrive at your product page where you can download specific Manuals and Software & Utilities including: - Datalogic Aladdin™ a multi-platform utility program that allows device configuration using a PC.
POWERSCAN® D8530 FAMILY COMPLIANCE Aiming System Imager Beam Output Window CE COMPLIANCE This is a Class A product . In a domestic environment this product may cause radio interference, in which case the user may be required to take adequate measures. WARNING FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment. This device complies with PART 15 of the FCC Rules.
DATALOGIC LASER SAFETY The PowerScan® D8530 hand-held reader is a Class 1 LED product regarding its Illuminator and a Class 2 laser product regarding its Aiming System. LED Illuminator The use of an illuminator in the PowerScan® D8530 hand-held reader is a Class 1 LED product: ILLUMINATORE LED CLASSE 1 AUSLEUCHTER LED KLASSE 1 ILLUMINATEUR A LED DE CLASSE 1 ILUMINADOR LED DE CLASE 1 Aiming System The PowerScan® D8530 aiming system meets the Class 2 requirements for laser safety.
POWERSCAN® D8530 FAMILY ENGLISH The following information is provided to comply with the rules imposed by international authorities and refers to the correct use of your terminal. STANDARD LASER SAFETY REGULATIONS This product conforms to the applicable requirements of both CDRH 21 CFR 1040 and EN 60825-1 at the date of manufacture. For installation, use and maintenance, it is not necessary to open the device.
DATALOGIC DEUTSCH Die folgenden Informationen stimmen mit den Sicherheitshinweisen überein, die von internationalen Behörden auferlegt wurden, und sie beziehen sich auf den korrekten Gebrauch vom Terminal. NORM FÜR DIE LASERSICHERHEIT Dies Produkt entspricht am Tag der Herstellung den gültigen EN 60825-1 und CDRH 21 CFR 1040 Normen für die Lasersicherheit. Es ist nicht notwendig, das Gerät wegen Betrieb oder Installations-, und Wartungs-Arbeiten zu öffnen.
POWERSCAN® D8530 FAMILY ESPAÑOL Las informaciones siguientes son presentadas en conformidad con las disposiciones de las autoridades internacionales y se refieren al uso correcto del terminal. NORMATIVAS ESTÁNDAR PARA LA SEGURIDAD LÁSER Este aparato resulta conforme a las normativas vigentes de seguridad láser a la fecha de producción: CDRH 21 CFR 1040 y EN 60825-1. No es necesario abrir el aparato para la instalación, la utilización o la manutención.
DATALOGIC WEEE COMPLIANCE Waste Electrical and Electronic Equipment (WEEE) Statement English For information about the disposal of Waste Electrical and Electronic Equipment (WEEE), please refer to the website at www.scanning.datalogic.com. Italian Per informazioni sullo smaltimento delle apparecchiature elettriche ed elettroniche consultare il sito Web www.scanning.datalogic.com.
POWERSCAN® D8530 FAMILY NOTES 25
DATALOGIC NOTES 26
EC-049 DECLARATION OF CONFORMITY REV.: 0 Pag.: 1 di 1 08 Datalogic Scanning Group Srl Via S.
Australia Japan Datalogic Scanning Pty Ltd North Ryde, Australia Telephone: [61] (2) 9870 3200 Fax: [61] (2) 9878 8688 Datalogic Scanning KK Shinagawa, Tokyo, Japan Telephone: 81 (0)3 3491 6761 Fax: 81 (0)3 3491 6656 France and Benelux Latin America Datalogic Scanning Sarl LES ULIS Cedex, France Telephone: [33].01.64.86.71.00 Fax: [33].01.64 46.72.