PowerScan™ M8300 Readers Industrial Handheld Laser Bar Code Reader with Datalogic’s STAR Cordless System™ Quick Reference Guide
Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”).
UPDATES AND LANGUAGE AVAILABILITY UK/US The latest drivers and documentation updates for this product are available on the Datalogic website at www.datalogic.com. I Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto. Collegarsi a : www.datalogic.com F Les versions mises à jour de drivers et documentation de ce produit sont disponibles sur Internet. Cliquez sur : www.datalogic.
Using PowerScan™ M8300 USING POWERSCAN™ M8300 The PowerScan™ M8300 series readers can be used with either an BC-80X0 cradle or Stargate™ radio base station to build a Cordless Reading System for the collection, decoding and transmission of barcoded data. PowerScan™ M8300 laser readers automatically scan barcodes at a distance. Simply aim and pull the trigger. SCAN LINE POSITION Code scanning is performed along the scan line emitted from the reading window. This line must cross the entire code.
Using PowerScan™ M8300 AIMING SYSTEM PowerScan™ M8300 provides an aiming system. If enabled, a partial trigger press produces a red spot, which should be aimed over the code center to get the best reading performance, see figure (1) above. By completely pressing the trigger the scan line appears to start the code scanning (2).
Charging the Batteries CHARGING THE BATTERIES Once the BC-80X0/C-8000 is powered, you can charge the reader's batteries. Place the PowerScan™ M8300 into the BC-80X0 cradle or the C-8000 battery charger. The "Reader" LED on the cradle/battery charger turns red. The battery is completely charged when the "Reader" LED on the cradle/battery charger turns green. To change the batteries, unscrew the retaining screw and extract the battery pack from the reader handle.
Charging the Batteries SETUP PowerScan™ M8300/BC-80X0 Point-to Point Configuration 1. Connect an BC-80X0 cradle to the Host. For installation and connection information see the BC-80X0 Quick Reference Manual. 2. Charge the PowerScan™ M8300 battery using an BC-80X0 or the C-8000 charger as described in this Quick Reference manual. A full charge takes 4 hours if using an external power supply; while it takes up to 10 hours if supplying power through the USB port. 3.
PowerScan™ M8300 Configuration POWERSCAN™ M8300 CONFIGURATION PowerScan™ M8300/BC-80X0 Point-to-Point Setup A rapid configuration procedure has been devised for point-to-point applications where a single reader is associated exclusively with its own BC-80X0 base station and where it is not necessary to set the Date and Time parameters.
PowerScan™ M8300 Configuration POWERSCAN™ M8300/BC-80X0 STAND ALONE SETUP When the BC-80X0 cradle is connected and powered, configure the PowerScan™ M8300 by reading the following codes in the given sequence and follow the instructions. Note: for the numeric code selection of steps 3, 4, and 5 use the table at the end of this Quick Reference. 1. Restore PowerScan™ M8300 Default Ì$+$*oÎ 2. Enter Configuration Ì$+;Î 3. Set Date ÌIA%Î + six digits for Day, Month and Year (DDMMYY). 4.
PowerScan™ M8300 Configuration 7. Read the Bind code to pair the PowerScan™ M8300 to the BC-80X0 cradle. The reader is dedicated to the cradle. Any previously bound reader will be excluded. To connect several readers to the same cradle see the following section "Using Multiple Readers with Same Cradle". Bind Ì$+RN0$-IÎ The green LED on the PowerScan™ M8300 will blink: the reader is ready to be positioned onto the cradle. 8.
PowerScan™ M8300 Configuration USING MULTIPLE READERS WITH SAME CRADLE If you want to use several readers associated with the same cradle, you must first Bind the cradle with one of the readers (see previously described configuration procedure). Successive readers can be associated with the same cradle by following the configuration procedure substituting the Bind command with Join. 7. Join Ì$+RN1$-NÎ The green LED on the PowerScan™ M8300 will blink: the reader is ready to be positioned onto the cradle.
PowerScan™ M8300 Configuration POWERSCAN™ M8300/STAR-SYSTEM™ SETUP The following procedure allows configuring a PowerScan™ M8300 reader to communicate with various STAR-System™ devices such as Stargate™ RF base stations: 1. Restore PowerScan™ M8300 Default Ì$+$*oÎ 2. Enter Configuration Ì$+;Î 3. Set Date ÌIA%Î + six digits for Day, Month and Year (DDMMYY). 4. Set Time ÌIB'Î + four digits for Hours and Minutes (HHMM). 5.
PowerScan™ M8300 Configuration 6. Set Radio Address ÌRF8Î + four digits from the Numeric Table for the PowerScan™ M8300 Address (from 0000 to 1999). All readers used in the same area must have different addresses. 7. Set First STAR-System™ Address ÌRSRÎ + four digits from the Numeric Table in the range 0000 to 1999 8.
PowerScan™ M8300 Default Configuration POWERSCAN™ M8300 DEFAULT CONFIGURATION DATA FORMAT code identifier disabled, field adjustment disabled, code length not transmitted, character replacement disabled CODE SELECTION enabled codes • EAN 8/EAN 13 / UPC A/UPC E without ADD ON check digit transmitted, no conversions • Interleaved 2/5 check digit control and transmission, variable length code; 4-99 characters • Standard Code 39 no check digit control, variable length code; 1-99 characters • Code 128 variable
Technical Features TECHNICAL FEATURES Electrical Features Battery Type 2150 Li-Ion battery pack Time of recharge max. 4 hours with external power supply max. 10 hours with Host power Operating autonomy (continuous reading) 60,000 reads (typical) Display (Only available models) with some Indicators LCD 4 lines x 16 chars Programmable font and backlight Good Read LED green Good Read Spot green Beeper Laser Features M8300 M8300-AR Power (max) in mW 0.9 mW 1.
Reading Diagrams READING DIAGRAMS PowerScan™ M8300 24 12 36 48 60 72 84 96 108 cm 36 24 0.13 mm (5 mils) 12 0 12 0.19 mm (7.5 mils) 0.25 mm (10 mils) 0.33 mm (13 mils) 24 0.38 mm (15 mils) 0.50 mm (20 mils) 36 cm 1.00 mm (40 mils) 1.38 mm (55 mils) PowerScan™ M8300 AR 100 200 300 400 500 300 1.75 mm * (70 mils) 200 600 700 800 900 1000 cm 2.50 mm * (100 mils) 100 0 100 200 1.00 mm (40 mils) 1.
Warranty WARRANTY Datalogic warranties this product against defects in workmanship and materials, for a period of 3 years from the date of shipment, provided that the product is operated under normal and proper conditions. Datalogic has the faculty to repair or replace the product; these provisions do not prolong the original warranty term. The warranty does not apply to any product that has been subject to misuse, accidental damage, unauthorized repair or tampering.
Compliance COMPLIANCE This device must be opened by qualified personnel only. The batteries must be removed before opening the device. FCC COMPLIANCE Modifications or changes to this equipment without the expressed written approval of Datalogic could void the authority to use the equipment. This device complies with PART 15 of the FCC Rules.
Compliance The laser scanner utilizes a low-power laser diode. Although staring directly at the laser beam momentarily causes no known biological damage, avoid staring at the beam as one would with any very strong light source, such as the sun. Avoid that the laser beam hits the eye of an observer, even through reflective surfaces such as mirrors, etc.
Compliance WEEE COMPLIANCE Waste Electrical and Electronic Equipment (WEEE) Statement English For information about the disposal of Waste Electrical and Electronic Equipment (WEEE), please refer to the website at www.scanning.datalogic.com. Italian Per informazioni sullo smaltimento delle apparecchiature elettriche ed elettroniche consultare il sito Web www.scanning.datalogic.com.
Numeric Table NUMERIC TABLE Ì01Î 0 Ì12Î 1 Ì23Î 2 Ì34Î 3 Ì45Î 4 Ì56Î 5 Ì67Î 6 Ì78Î 7 Ì89Î 8 Ì9:Î 9 Quick Reference Guide 19
Numeric Table NOTES 20 PowerScan™ M8300
Datalogic Scanning, Inc.
Australia Datalogic Scanning Pty Ltd Telephone: [61] (2) 9870 3200 australia.scanning@datalogic.com Japan Datalogic Scanning KK Telephone: 81 (0)3 3491 6761 japan.scanning@datalogic.com France and Benelux Datalogic Scanning SAS Telephone: [33].01.64.86.71.00 france.scanning@datalogic.com Latin America Datalogic Scanning, Inc Telephone: (305) 591-3222 latinamerica.scanning@datalogic.com Germany Datalogic Scanning GmbH Telephone: 49 (0) 61 51/93 58-0 germany.scanning@datalogic.