PowerScan™ M8500 Readers Industrial Handheld Area Imager Bar Code Reader with Datalogic’s STAR Cordless System™ Quick Reference Guide
Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of Datalogic Scanning, Inc. or its subsidiaries or affiliates ("Datalogic" or “Datalogic Scanning”).
Table of Contents Table of Contents .............................................................................1 Updates and Language Availability ...................................................... 3 PowerScan® M8500 Family ............................................................. 4 Description ..................................................................................................... 4 Using the PowerScan® PM8500 Family ............................................... 5 Indicators .....
NOTES 2 PowerScan® PM8500
Updates and Language Availability UK/US The latest drivers and documentation updates for this product are available on Internet. Log on to : www.scanning.datalogic.com I Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto. Collegarsi a : www.scanning.datalogic.com F Les versions mises à jour de drivers et documentation de ce produit sont disponibles sur Internet. Cliquez sur : www.scanning.datalogic.
PowerScan® M8500 Family Description The PowerScan® M8500 series readers can be used with either a BC-80X0 cradle or Stargate™ radio base station to build a Cordless Reading System for the collection, decoding and transmission of bar coded data. The M8500 series can be used in the same environment where M8300 series readers are already installed. This manual includes just the commands required for the startup of the scanner and setting of the interface.
Using the PowerScan® PM8500 Family Using the PowerScan® PM8500 Family The PowerScan® PM8500 normally functions by capturing and decoding codes. The PowerScan® PM8500 reader uses an intelligent aiming system. By pulling the trigger, the aiming system indicates a field of view, which should be positioned over the code: Aiming System When you pull the trigger, a red beam illuminates the code. If the aiming system is centered and the entire symbology is within the aiming system, you will get a good read.
Indicators Indicators LED Indicators The PowerScan® PM8500 family uses green LED indicators to signal the following reader functions: STATUS BEHAVIOR Power ON At power-on, the LEDs blink briefly, then light up for 2 seconds to signal the power supply is present. Normal Function The LED lights up after a good decoding and will switch off only at the next trigger press. Beeper The PowerScan® PM8500 basic software provides beeper signals for good/wrong reading and for indicating errors.
Charging the Batteries Charging the Batteries Once the BC-80X0/C-8000 is powered, you can charge the reader's batteries. Place the PowerScan® M8500 into the BC-80X0 cradle or the C-8000 battery charger. The "Reader" LED on the cradle/battery charger turns red. The battery is completely charged when the "Reader" LED on the cradle/battery charger turns green. To change the battery, push the Release Button as indicated by Arrow 1 and extract the battery pack from the reader handle.
Charging the Batteries WARNING Do not discharge the battery using any device except for the scanner. When the battery is used in devices other than the designated product, it may damage the battery or reduce its life expectancy. If the device causes an abnormal current to flow, it may cause the battery to become hot, explode or ignite and cause serious injury. Lithium-ion battery packs may get hot, explode or ignite and cause serious injury if exposed to abusive conditions.
Setup Setup PowerScan® M8500/BC-80X0 Point-to Point Configuration 1. 2. 3. 4. Connect a BC-80X0 cradle to the Host. For installation and connection information see the BC-80X0 Quick Reference Manual. Charge the PowerScan® M8500 battery using an BC-80X0 or the C-8000 charger as described in this Quick Reference manual. A full charge takes 4 hours if using an external power supply; while it takes up to 10 hours if supplying power through the USB port.
PowerScan® M8500 Configuration PowerScan® M8500 Configuration PowerScan® M8500/BC-80X0 Point-to-Point Setup A rapid configuration procedure has been devised for point-to-point applications where a single reader is associated exclusively with its own BC-80X0 base station and where it is not necessary to set the Date and Time parameters.
PowerScan® M8500 Configuration PowerScan® M8500/BC-80X0 Stand Alone Setup When the BC-80X0 cradle is connected and powered, configure the PowerScan® M8500 by reading the following codes in the given sequence and follow the instructions. For the numeric code selection of steps 3, 4, and 5 use the table at the end of this Quick Reference 1. Restore PowerScan® M8500 Default 2. Enter Configuration 3. Set Date + six digits for Day, Month and Year (DDMMYY).
PowerScan® M8500 Configuration 4. Set Time + four digits for Hours and Minutes (HHMM). 5. Set Radio Address + four digits for the PowerScan® M8500 Address (from 0000 to 1999). All readers used in the same area must have different addresses. 6. Exit and Save Configuration 7. Read the Bind code to pair the PowerScan® M8500 to the BC-80X0 cradle. The reader is dedicated to the cradle. Any previously bound reader will be excluded.
PowerScan® M8500 Configuration 8. Firmly position the reader onto the cradle within 10 seconds, a beep will be emitted, signaling that the BC-80X0 cradle has been paired to the PowerScan® M8500, and the green LED on the reader will go off. Green LED 9. Configure the BC-80X0 cradle, refer to the “BC-80X0 Quick Reference”. END of procedure. YOUR READER IS NOW READY TO READ CODES.
PowerScan® M8500 Configuration Using Multiple Readers with Same Cradle If you want to use several readers associated with the same cradle, you must first Bind the cradle with one of the readers (see previously described configuration procedure). Successive readers can be associated with the same cradle by following the configuration procedure substituting the Bind command with Join. 7. Join The green LED on the PowerScan® M8500 will blink: the reader is ready to be positioned onto the cradle.
PowerScan® M8500 Configuration PowerScan® M8500/STAR-SYSTEM™ Setup The following procedure allows configuring a PowerScan® M8500 reader to communicate with various STAR-System™ devices such as Stargate™ RF base stations: 1. Restore PowerScan® M8500 Default 2. Enter Configuration 3. Set Date + six digits for Day, Month and Year (DDMMYY). 4. Set Time + four digits for Hours and Minutes (HHMM).
PowerScan® M8500 Configuration 5. Set the connection according to the length of the codes to be read: Code Length 240 Characters Code Length 240 Characters (not for systems with BC-80X0 as Master) 6. Set Radio Address + four digits from the Numeric Table for the PowerScan® M8500 Address (from 0000 to 1999). All readers used in the same area must have different addresses. 7.
PowerScan® M8500 Configuration 8. Set Last STAR-System™ Address + four digits from the Numeric Table in the range 0000 to 1999 Whenever the system is composed of a single base station, the first and last base station addresses (steps 7 and 8) must have the same value. 9. Exit and Save Configuration END of procedure. YOUR READER IS NOW READY TO READ CODES.
Default Configuration Default Configuration DATA FORMAT – Symbology Dependent Parameters symbology specific format = select all, no headers, no terminators, symbology character substitution disabled, symbology character deletion disabled DATA FORMAT – Concatenation Concatenation disabled, 2 EAN/UPC codes concatenated, Set First Concatenated Code Length 000 = any length, Set Second Concatenated Code Length 000 = any length, Set Third Concatenated Code Length 000 = any length, Set Fourth Concatenated Code L
Operating Test Operating Test EAN-13 Code 39 (Standard) 1 234567 000992 Code 128 t e s 1 7 1 6 2 PDF417 t QR Quick Reference Guide Data Matrix (Normal) 19
Technical Features Technical Features PowerScan® M8500 Family Common Features Electrical Features Battery Type Time of recharge 2150 Li-Ion battery pack max. 4 hours with external power supply max. 10 hours with Host power Operating autonomy (continuous reading) Display (Only available with some models) 30,000 reads (typical) LCD 4 lines x 16 chars Programmable font and backlight Good Read LED green Good Read Spot green Beeper Indicators Radio Features European Models Radio Frequency 433.
Technical Features PowerScan® M8500 Family Common Features (continued) Optical Features Sensor 1280 x 1024 pixel element, 2D CMOS Array Illuminator LED array Wavelength In the range 630 ~ 670 nm LED Safety Class Class 1 to EN 60825-1 Aiming System Visible Laser Diode Wavelength Laser Safety Class Ambient light Quick Reference Guide 650 nm Class 2 - EN 60825-1; Class II CDRH 0 - 100000 lux 21
Technical Features PowerScan® M8500™ Optical Features Focus distance 140 mm Field of view 28°(H )x 23°(V) Horizontal field of view at distance (d) in mm 0.52d + 15 Vertical field of view at distance (d) in mm 0.42d + 12 Max Resolution Linear codes - mm (mils) PDF417 - mm (mils) Datamatrix – mm (mils) 0.10 (4) 0.10 (4) 0.17 (6.6) Depth of field* 1D (linear): Code39 EAN13 2D: PDF417 QR DataMatrix X-dimension mm (mils) DOF cm (in) 0.13 (5) 7.5 to 15.5 (2.95 to 6.10) 0.5 (20) 5.5 to 36.
Technical Features PowerScan® M8500™ HD Optical Features Focus distance 65 mm Field of view 27° (H) x 22° (V) Horizontal field of view at distance (d) in mm 0.50d + 13 Vertical field of view at distance (d) in mm 0.40d + 10 Max Resolution Linear codes - mm (mils) PDF 417 – mm (mils) Datamatrix – mm (mils) 0.05 (2 mils) 0.08 (3 mils) 0.10 (4 mils) Depth of field* 1D (linear): Code39 EAN13 2D: PDF417 QR DataMatrix X-dimension mm (mils) DOF cm (in) 0.08 (3) 4.5 to 8.0 (1.77 to 3.15) 0.
Technical Features PowerScan® M8500™ WA Optical Features Focus distance 110 mm Field of view 57° x 46° Horizontal field of view at distance (d) in mm 1.09d + 38 Vertical field of view at distance (d) in mm 0.85d + 30 Max Resolution Linear codes - mm (mils) PDF 417 – mm (mils) Datamatrix – mm (mils) 0.13 (5 mils) 0.13 (5 mils) 0.19 (7.5 mils) Depth of field* 1D (linear): Code39 EAN 13 2D: PDF417 QR DataMatrix X-dimension mm (mils) DOF cm (in) 0.13 (5) 2.5 to 10.0 (0.98 to 3.94) 0.
Services and Support Services and Support Datalogic provides several services as well as technical support through its website. Log on to www.scanning.datalogic.com and click on the links indicated for further information including: Products Search through the links to arrive at your product page where you can download specific Manuals and Software & Utilities including: • Datalogic Aladdin™, a multi-platform utility program that allows device configuration using a PC.
Compliance Compliance This device must be opened by qualified personnel only. The batteries must be removed before opening the device. FCC Compliance Modifications or changes to this equipment without the express written approval of Datalogic could void the authority to use the equipment. This device complies with PART 15 of the FCC Rules.
Compliance Laser Safety The PowerScan® PM8500 handheld reader is a Class 1 LED product regarding its Illuminator and a Class 2 laser product regarding its Aiming System. LED Illuminator The use of an illuminator in the PowerScan® PM8500 handheld reader is a Class 1 LED product: ILLUMINATORE LED CLASSE 1 AUSLEUCHTER LED KLASSE 1 ILLUMINATEUR A LED DE CLASSE 1 ILUMINADOR LED DE CLASE 1 Aiming System The PowerScan® PM8500 aiming system meets the Class 2 requirements for laser safety.
Compliance ENGLISH The following information is provided to comply with the rules imposed by international authorities and refers to the correct use of your terminal. STANDARD LASER SAFETY REGULATIONS This product conforms to the applicable requirements of both CDRH 21 CFR 1040 and EN 60825-1 at the date of manufacture. For installation, use and maintenance, it is not necessary to open the device.
Compliance DEUTSCH Die folgenden Informationen stimmen mit den Sicherheitshinweisen überein, die von internationalen Behörden auferlegt wurden, und sie beziehen sich auf den korrekten Gebrauch vom Terminal. NORM FÜR DIE LASERSICHERHEIT Dies Produkt entspricht am Tag der Herstellung den gültigen EN 60825-1 und CDRH 21 CFR 1040 Normen für die Lasersicherheit. Es ist nicht notwendig, das Gerät wegen Betrieb oder Installations-, und Wartungs-Arbeiten zu öffnen.
Compliance ESPAÑOL Las informaciones siguientes son presentadas en conformidad con las disposiciones de las autoridades internacionales y se refieren al uso correcto del terminal. NORMATIVAS ESTÁNDAR PARA LA SEGURIDAD LÁSER Este aparato resulta conforme a las normativas vigentes de seguridad láser a la fecha de producción: CDRH 21 CFR 1040 y EN 60825-1. No es necesario abrir el aparato para la instalación, la utilización o la manutención.
Compliance WEEE Compliance Waste Electrical and Electronic Equipment (WEEE) Statement English For information about the disposal of Waste Electrical and Electronic Equipment (WEEE), please refer to the website at www.scanning.datalogic.com. Italian Per informazioni sullo smaltimento delle apparecchiature elettriche ed elettroniche consultare il sito Web www.scanning.datalogic.com.
Numeric Table Numeric Table 0 1 ANFOGIFKDNGNENEIEPANHOGOCK AHPNIBAMDKEOFMHMLJAKFHBHIK AKCBPJCJGIIJCMCFGPOFMJLDJK AEFBJLBGMHPKNIFGJCGBBDNHGK AAPHBAJJDEBJCDJAGBDLGHNFHK AFKEBJJPCPKMAJNAMBKKKCFJKK DLDLLLDDDLLLLLLDLLDDDLDLLL ANEPGIFKDNGNENEIEPANHOGOCK AHPNIBAMDKEOFMHMLJALEHEEIK AKCBPJCJGIIJCMCEHPLFIKNHNK AEFBJLBGMHPKMKGPIEMNLKLEGK AAPHBAJIDGFBMBLDDDNIEPNNFK AEKEBJMNMOKOIOPNEFCOIJJLJK DLDLLLDDLDDLLLLDDDLDDLDLLL 2 ANEOGIFKDNGNENEIEPANHOGOCK AHPNIBAMDKEOFMHMLJAKEFGHIK AKCBPJCJGIIJCMCEGMILJPPDNK AEFBJLBGMHPKMK
Numeric Table 5 6 AMEPGIFKDNGNENEIEPANHOGOCK AHPNIBAMDKEOFMHMLJAKFAAEIK AKCBPJCJGIIJCMCEGJNDOAMLNK AEFBJLBGMHPLMLCPBCACOJIFGK AAPHBAJIDCFJGLHNIKABJCDBBK AHKEBJNIIGGECEIHHDDMMFLLIK DDDLLLDDLLDLLLLDLLDDDLDLDL AMEOGIFKDNGNENEIEPANHOGOCK AHPNIBAMDKEOFMHMLJALFCCHIK AKCBPJCJGIIJCMCEHKONPFOPNK AEFBJLBGMHPLMLAKPMMDLFOFGK AAPHBAJJDAFFBDLFDPELPHEHHK AHLEBMLPCDIMIIAFIFJIMOLLKK DLLLLLDDDDDLLLLDDDDDDLDLDL 7 ANFNGIFKDNGNENEIEPANHOGOCK AHPNIBAMDKEOFMHMLJAKFCHFIK AKCBPJCJGIIJCMCEHJLAGJEHJK AEFBJLBGMHPKMMHJBODNLMGFGK A
Numeric Table NOTES 34 PowerScan® M8500
Numeric Table NOTES Quick Reference Guide 35
Numeric Table NOTES 36 PowerScan® M8500
DECLARATION OF CONFORMITY 09 Datalogic Scanning Group Srl Via S.
Australia Datalogic Scanning Pty Ltd Telephone: [61] (2) 9870 3200 australia.scanning@datalogic.com Japan Datalogic Scanning KK Telephone: 81 (0)3 3491 6761 japan.scanning@datalogic.com France and Benelux Datalogic Scanning Sarl Telephone: [33].01.64.86.71.00 france.scanning@datalogic.com Latin America Datalogic Scanning, Inc Telephone: (305) 591-3222 latinamerica.scanning@datalogic.com Germany Datalogic Scanning GmbH Telephone: 49 (0) 61 51/93 58-0 germany.scanning@datalogic.