Installation manual
RAPID CONFIGURATION 
1 
1 
1  RAPID CONFIGURATION 
NOTE 
This  chapter  illustrates  a  Stand  Alone  application.  For  other  types  of 
installations,  such  as  ID-NET™,  Fieldbus,  Pass-Through,  Multiplexer 
Layout,  etc.,  refer  to  chapters  4,  5  and  6.  For  complete  scanner 
configuration  using  the  Genius™  configuration  program,  refer  to  the 
Context-Sensitive Help On-Line. 
STEP 1 – CONNECT THE SYSTEM 
To connect the system in a Stand Alone configuration, you need the hardware indicated in 
Figure 1. 
In this layout the data is transmitted to the Host on the main serial interface. 
In  Local  Echo  communication  mode,  data  is  transmitted  on  the  RS232  auxiliary  interface 
independently from the main interface selection. 
When  On-Line  Operating  mode  is  used,  the  scanner  is  activated  by  an  External  Trigger 
(photoelectric sensor) when the object enters its reading zone. 
Figure 1 – DS2400N in Stand Alone Layout 
DS2400N 
Host 
PG 6000 
P.S.* 
* Presence Sensor 
(for On-Line mode) 
MAIN 
I/O, AUX 
CBX100/500 