Installation manual
RAPID CONFIGURATION 
11 
1 
d.  Hardware interface selection 
e.  Output data format configuration 
The  On  Line operating  Mode  requires  the  reader  to  be  connected  to  an External 
Trigger/Presence Sensor using I1A and I1B inputs. 
The Automatic operating mode does not require connection to an external Presence 
Sensor.  When  working  in  this  mode  the  reader  is  continuously  scanning,  while  the 
reading phase is  activated each time a barcode enters  the reader reading zone. The 
reader stops reading after an N number of scans without a code. Barcode characters 
are transmitted on the serial interface. In case of a failed reading phase no message is 
sent to the host computer. 