2.2.1  How To Setup/Configure the Scanner Network 
A complete ID-NET™ scanner network can be rapidly setup, as follows: 
Mounting & Connection 
1.  Mechanically mount/install all the readers (refer to par. 3.2 and 3.2.5). 
2.  Wire ID-NET™ (refer to par. 4.3 or 5.3). 
3.  Connect  the planned  Master  scanner  to  a  PC  by  means  of  the Genius™  configuration 
software. 
4.  Power up the entire system. 
Configuration 
1.  Launch Genius™. 
2.  From the Genius™ Device Menu select “Local Device Network Settings” and program the 
Role of the Master scanner (Synchronized or Multidata). 
This procedure requires the Network Baud Rate be the same for all Slaves and Master, 
(500  kbs  is  the  default  value).  It  can  be  changed  after  network  setup  using  Genius™ 
through the Master scanner. See also the alternative procedure in the note below. 
3.  At  the  prompt  to  "Send  updated  Network  configuration  to  the  Local  Device"  (Master) 
choose "Yes". 
4.  Then  run  the  NET-AUTOSET  procedure  from  the  Icon  in  the  Devices  Area.  Genius™ 
sets  all  slave  scanners  according  to  the  Master  Role  (Synchronized  or  Multidata),  and 
assigns each a random address. If necessary, this address can be changed through the 
Network Wizard. 
5.  Configure the System parameters via Genius™. 
6.  If  using the CBX connection box equipped with a BM100 Backup module, perform 
System Backup at the Master. 
The scanner network is ready. 
NOTE 
If necessary, the ID-NET™ baudrate can be set individually on each Slave 
scanner to match the Master. Connect each Slave to Genius™ and set the 
Reading System Layout > Network Baudrate parameter. Then  follow the 
procedure above. 
NOTE 
An  alternative  method  of  programming  scanner  address  and  role 
assignment can be accomplished by using the "Connectivity Programming 
Barcodes"  (refer  to  the  "Setup  Procedure  Using  Programming  Barcodes" 
document on the product CD). 