Installation manual
DS2400N REFERENCE MANUAL 
74 
6 
6.2  PASS-THROUGH 
Pass-through mode allows two or  more  devices to be connected to a single external serial 
interface. 
Each  DS2400N  transmits  the  messages  received  by  the  Auxiliary  interface  onto  the  Main 
interface. All messages will be passed through this chain to the host. 
When  On-Line  Operating  mode  is  used,  the  scanner  is  activated  by  an  External  Trigger 
(photoelectric sensor) when the object enters its reading zone. 
Applications  can  be  implemented  to  connect  a  device  such  as  a  hand-held  reader  to  the 
Auxiliary port of the last scanner in the chain for manual code reading capability. 
The Main and Auxiliary ports are connected as shown in the figure below: 
Figure 87 – Pass-Through Layout 
Host 
1 
2 
3 
3 
1 
Device#1 
3 
Main Serial Interface (RS232 only) 
 Auxiliary Serial Interface (RS232) 
 External Trigger (for On-Line Mode) 
2 
1 
Device#2 
Device#n 
2 
Power 