TYPICAL LAYOUTS 
75 
6 
An alternative Pass-Through layout allows the more efficient ID-NET™ network to be used. 
This  layout is  really  an  ID-NET  Master/Slave  Multidata  layout  which  also  allows  each 
scanner (Master and Slaves) to  accept input  on the Auxiliary interface,  for example to 
connect a device such as a hand-held reader for manual code reading capability. 
Each  DS2400N  transmits  its  own  messages  plus  any  messages  received  by  its  Auxiliary 
interface onto the ID-NET™ interface. The Master passes all messages to the Host. 
When  On-Line  Operating  mode  is  used,  the  scanner  is  activated  by  an  External  Trigger 
(photoelectric sensor) when the object enters its reading zone. 
Figure 88 – Pass-Through On ID-NET™ Layout 
Host 
1 
4 
3 
3 
Master 
3 
Main Serial Interface (RS232 or RS485) 
 Auxiliary Serial Interface (RS232) 
 External Trigger (for On-Line Mode) 
 ID-NET™ 
Slave#2 
Slave#n 
2 
Power 
2 