Instruction manual
RAPID CONFIGURATION 
17 
1 
STEP 9 – TEST MODE 
Use a code suitable to your application to test the reading performance of the system. 
1.  Enter  the  Test  function  by  pressing  and  holding  the  X-PRESS™  push  button  until  the 
Test LED is on. 
2.  Release the button to enter the Test function. 
Once  entered,  the  Bar Graph  on  the  five  LEDs  is activated  and  if  the  reader  starts 
reading codes the Bar-Graph shows the Good Read Rate. In case of no read condition, 
only the STATUS LED is on and blinks. 
READY 
green 
green 
yellow 
yellow 
red 
SETUP 
FOCUS 
TEST 
LEARN 
GOOD 
TRIGGER 
COM 
STATUS 
Figure 17 – X-PRESS™ Interface: Test Function 
3.  To exit the Test, press the X-PRESS™ push button once. 
NOTE 
By default, the Test exits automatically after three minutes. 
The Bar Graph has the following meaning: 
READY 
 95% 
 75% 
 60% 
 40% 
 20% 
SETUP 
FOCUS 
TEST 
LEARN 
GOOD 
TRIGGER 
COM 
STATUS 