Instruction manual
INTRODUCTION 
37 
2 
Setup (Function 3) 
Once entered, the imager automatically performs Image Acquisition parameter calibration for 
the specific code presented to it. 
The Setup LED will blink until the procedure is completed. 
The Setup procedure ends when the Image Acquisition parameters are successfully saved in 
the reader memory, the Setup LED will remain on continuously and Matrix 410™ emits 3 high 
pitched beeps. 
If the calibration cannot be reached after a timeout of about 5 (five) seconds Matrix 410™ will 
exit without saving the parameters to memory, the Setup LED will not remain on continuously 
but it will just stop blinking. In this case Matrix 410™ emits a long low pitched beep. 
Learn (Function 4) 
Once  entered,  the  imager starts a  procedure  to  automatically  detect  and  recognize  codes 
which are presented to it. 
The Learn LED will blink until the procedure is completed. 
The  Learn  procedure  ends  when  the  Image  Processing  and  Decoding  parameters  are 
successfully  saved  in  the  reader  memory,  the  Learn  LED  will  remain  on  continuously  and 
Matrix 410™ emits 3 high pitched beeps. 
If the calibration cannot be reached after a timeout of about 3 (three) minutes, Matrix 410™ will 
exit without saving the parameters to memory, the Learn LED will not remain on continuously 
but it will just stop blinking. In this case Matrix 410™ emits a long low pitched beep. 
2.5.2  Diagnostic Indication 
The  "STATUS"  and  "READY"  LEDs  blink  simultaneously  while  the  "GOOD"  LED  is  on  to 
signal  the  presence of  an error.  Diagnostic  message  transmission  on interfaces  can  be 
enabled  to  provide  details  about  specific  error  conditions.  See  the  Diagnostic  Error 
Conditions chart in the Help On Line. 
LED 
STATUS 
READY 
BLINK 
GOOD 
ON to indicate an error 
TRIGGER 
COM 
STATUS 
BLINK 
READY 
SETUP 
FOCUS 
TEST 
LEARN 
GOOD 
TRIGGER 
COM 
STATUS 