Instruction manual
MATRIX 410™ CONNECTOR ELECTRICAL CONNECTIONS 
81 
5 
5.5.2  ID-NET™ Response Time 
The following figure shows the response time of the ID-NET™ network. This time is defined 
as the period between the Trigger activation and the beginning of data transmission to the 
Host. 
Max ID-NET™ Response Time 
240 
220 
200 
180 
160 
140 
120 
100 
80 
60 
40 
20 
0 
Response Time (ms) 
Number of Nodes 
500 kbps 
250 kbps 
125 kbps 
0 
1 
2 
3 
4 
5 
6 
7 
8 
9 
10 
11 
12 
13 
14 
15 
16 
Figure 81 – ID-NET™ Response Time 
CONDITIONS: 
  ID-NET™ M/S Synchronized layout 
  message length = 50 bytes per node 