Product specifications

Codabar
Product Reference Guide 199
Codabar — continued
Codabar Data Group Characters
Once you’ve pre-set your desired Data Group Characters
1
using the Data Group
Characters
feature found in Chapter 5, Data Editing, you can choose to output
up to two of those pre-sets whenever a Codabar bar code is scanned.
To set this feature:
1. Determine which Data Group pre-set(s) to output. You can select up to
two from the following:
Data Group 1 * Data Group 2 * Data Group 3 * Data Group 4
For example, your choice might be Data Group 2 only; Data Groups 1
and 3; Data Groups 3 and 4; or no Data Groups.
2. Scan the START bar code to place the imager in Programming Mode.
3. Scan the SET CODABAR DATA GROUP CHARACTERS bar code.
4. Turn to
Appendix B, Alpha-Numeric Pad and scan the digits representing
the Data Group designation(s) chosen in the first step above. A digit of
value zero (0) selects “no group.” For example, scanning 3 and 0 would
output only the character(s) set for Data Group 3 whenever a Codabar
bar code was scanned. Scanning digits 1 and 2 would output both Data
Groups 2 and 3. To select no Data Groups at all, scan 0, then 0 again.
5. Scan the SET bar code to accept the digits scanned.
6. Scan the END bar code to exit Programming Mode.
1. In that chapter, you can select which character(s) and position(s) to place Data Characters within
scanned data output.
NOTE
The options in this section set Data Group Characters
for the Codabar symbology ONLY. If you wish to enable
this feature for additional symbologies, turn to the
options in the section specific to the other symbol-
ogy(s).